Dedicated computer-aided detection software for automated 3D breast ultrasound: an efficient tool for the radiologist in supplemental screening of women with dense breasts

Objectives - To determine the effect of computer-aided-detection (CAD) software for automated breast ultrasound (ABUS) on reading time (RT) and performance in screening for breast cancer. - - Material and methods - Unilateral ABUS examinations of 120 women with dense breasts were randomly selected...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Zelst, Jan C.M. van (VerfasserIn) , Tan, Tao (VerfasserIn) , Clauser, Paola (VerfasserIn) , Domingo, Angels (VerfasserIn) , Dorrius, Monique D. (VerfasserIn) , Drieling, Daniel (VerfasserIn) , Golatta, Michael (VerfasserIn) , Gras, Francisca (VerfasserIn) , de Jong, Mathijn (VerfasserIn) , Pijnappel, Ruud (VerfasserIn) , Rutten, Matthieu J. C. M. (VerfasserIn) , Karssemeijer, Nico (VerfasserIn) , Mann, Ritse M. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 7 February 2018
In: European radiology
Year: 2018, Jahrgang: 28, Heft: 7, Pages: 2996-3006
ISSN:1432-1084
DOI:10.1007/s00330-017-5280-3
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s00330-017-5280-3
Verlag, lizenzpflichtig, Volltext: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5986849/
Volltext
Verfasserangaben:Jan C.M. van Zelst, Tao Tan, Paola Clauser, Angels Domingo, Monique D. Dorrius, Daniel Drieling, Michael Golatta, Francisca Gras, Mathijn de Jong, Ruud Pijnappel, Matthieu J.C.M. Rutten, Nico Karssemeijer, Ritse M. Mann

MARC

LEADER 00000caa a2200000 c 4500
001 1693145294
003 DE-627
005 20220818015156.0
007 cr uuu---uuuuu
008 200323s2018 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00330-017-5280-3  |2 doi 
035 |a (DE-627)1693145294 
035 |a (DE-599)KXP1693145294 
035 |a (OCoLC)1341310637 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Zelst, Jan C.M. van  |e VerfasserIn  |0 (DE-588)1206899778  |0 (DE-627)1693145081  |4 aut 
245 1 0 |a Dedicated computer-aided detection software for automated 3D breast ultrasound  |b an efficient tool for the radiologist in supplemental screening of women with dense breasts  |c Jan C.M. van Zelst, Tao Tan, Paola Clauser, Angels Domingo, Monique D. Dorrius, Daniel Drieling, Michael Golatta, Francisca Gras, Mathijn de Jong, Ruud Pijnappel, Matthieu J.C.M. Rutten, Nico Karssemeijer, Ritse M. Mann 
264 1 |c 7 February 2018 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 23.03.2020 
520 |a Objectives - To determine the effect of computer-aided-detection (CAD) software for automated breast ultrasound (ABUS) on reading time (RT) and performance in screening for breast cancer. - - Material and methods - Unilateral ABUS examinations of 120 women with dense breasts were randomly selected from a multi-institutional archive of cases including 30 malignant (20/30 mammography-occult), 30 benign, and 60 normal cases with histopathological verification or ≥ 2 years of negative follow-up. Eight radiologists read once with (CAD-ABUS) and once without CAD (ABUS) with > 8 weeks between reading sessions. Readers provided a BI-RADS score and a level of suspiciousness (0-100). RT, sensitivity, specificity, PPV and area under the curve (AUC) were compared. - - Results - Average RT was significantly shorter using CAD-ABUS (133.4 s/case, 95% CI 129.2-137.6) compared with ABUS (158.3 s/case, 95% CI 153.0-163.3) (p < 0.001). Sensitivity was 0.84 for CAD-ABUS (95% CI 0.79-0.89) and ABUS (95% CI 0.78-0.88) (p = 0.90). Three out of eight readers showed significantly higher specificity using CAD. Pooled specificity (0.71, 95% CI 0.68-0.75 vs. 0.67, 95% CI 0.64-0.70, p = 0.08) and PPV (0.50, 95% CI 0.45-0.55 vs. 0.44, 95% CI 0.39-0.49, p = 0.07) were higher in CAD-ABUS vs. ABUS, respectively, albeit not significantly. Pooled AUC for CAD-ABUS was comparable with ABUS (0.82 vs. 0.83, p = 0.53, respectively). - - Conclusion - CAD software for ABUS may decrease the time needed to screen for breast cancer without compromising the screening performance of radiologists. - - Key Points - • ABUS with CAD software may speed up reading time without compromising radiologists’ accuracy., - • CAD software for ABUS might prevent non-detection of malignant breast lesions by radiologists. - , - • Radiologists reading ABUS with CAD software might improve their specificity without losing sensitivity. 
700 1 |a Tan, Tao  |e VerfasserIn  |4 aut 
700 1 |a Clauser, Paola  |e VerfasserIn  |4 aut 
700 1 |a Domingo, Angels  |e VerfasserIn  |4 aut 
700 1 |a Dorrius, Monique D.  |e VerfasserIn  |4 aut 
700 1 |a Drieling, Daniel  |e VerfasserIn  |4 aut 
700 1 |a Golatta, Michael  |d 1974-  |e VerfasserIn  |0 (DE-588)132350386  |0 (DE-627)521535727  |0 (DE-576)299091392  |4 aut 
700 1 |a Gras, Francisca  |e VerfasserIn  |4 aut 
700 1 |a de Jong, Mathijn  |e VerfasserIn  |4 aut 
700 1 |a Pijnappel, Ruud  |e VerfasserIn  |4 aut 
700 1 |a Rutten, Matthieu J. C. M.  |e VerfasserIn  |4 aut 
700 1 |a Karssemeijer, Nico  |e VerfasserIn  |4 aut 
700 1 |a Mann, Ritse M.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t European radiology  |d Berlin : Springer, 1991  |g 28(2018), 7, Seite 2996-3006  |h Online-Ressource  |w (DE-627)268757526  |w (DE-600)1472718-3  |w (DE-576)103868070  |x 1432-1084  |7 nnas  |a Dedicated computer-aided detection software for automated 3D breast ultrasound an efficient tool for the radiologist in supplemental screening of women with dense breasts 
773 1 8 |g volume:28  |g year:2018  |g number:7  |g pages:2996-3006  |g extent:11  |a Dedicated computer-aided detection software for automated 3D breast ultrasound an efficient tool for the radiologist in supplemental screening of women with dense breasts 
856 4 0 |u https://doi.org/10.1007/s00330-017-5280-3  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5986849/  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200323 
993 |a Article 
994 |a 2018 
998 |g 132350386  |a Golatta, Michael  |m 132350386:Golatta, Michael  |d 910000  |d 910400  |e 910000PG132350386  |e 910400PG132350386  |k 0/910000/  |k 1/910000/910400/  |p 7 
999 |a KXP-PPN1693145294  |e 3611998028 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"11 S."}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"doi":["10.1007/s00330-017-5280-3"],"eki":["1693145294"]},"relHost":[{"note":["Gesehen am 06.02.2018","Ungezählte Beil.: Supplement"],"id":{"eki":["268757526"],"issn":["1432-1084","1613-3757"],"zdb":["1472718-3"]},"part":{"extent":"11","issue":"7","volume":"28","text":"28(2018), 7, Seite 2996-3006","year":"2018","pages":"2996-3006"},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"subtitle":"official organ of the European Association of Radiology","title_sort":"European radiology","title":"European radiology"}],"origin":[{"dateIssuedKey":"1991","publisherPlace":"Berlin ; Heidelberg","publisher":"Springer","dateIssuedDisp":"1991-"}],"corporate":[{"role":"isb","display":"European Association of Radiology"}],"pubHistory":["1.1991 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"European radiology / Supplement"},{"title":"European radiology supplements"}],"language":["eng"],"recId":"268757526","disp":"Dedicated computer-aided detection software for automated 3D breast ultrasound an efficient tool for the radiologist in supplemental screening of women with dense breastsEuropean radiology"}],"note":["Gesehen am 23.03.2020"],"person":[{"role":"aut","family":"Zelst","display":"Zelst, Jan C.M. van","given":"Jan C.M. van"},{"given":"Tao","display":"Tan, Tao","family":"Tan","role":"aut"},{"role":"aut","family":"Clauser","given":"Paola","display":"Clauser, Paola"},{"role":"aut","given":"Angels","display":"Domingo, Angels","family":"Domingo"},{"role":"aut","display":"Dorrius, Monique D.","given":"Monique D.","family":"Dorrius"},{"role":"aut","given":"Daniel","display":"Drieling, Daniel","family":"Drieling"},{"family":"Golatta","display":"Golatta, Michael","given":"Michael","role":"aut"},{"role":"aut","given":"Francisca","display":"Gras, Francisca","family":"Gras"},{"role":"aut","display":"de Jong, Mathijn","given":"Mathijn","family":"de Jong"},{"family":"Pijnappel","display":"Pijnappel, Ruud","given":"Ruud","role":"aut"},{"role":"aut","family":"Rutten","display":"Rutten, Matthieu J. C. M.","given":"Matthieu J. C. M."},{"family":"Karssemeijer","display":"Karssemeijer, Nico","given":"Nico","role":"aut"},{"role":"aut","display":"Mann, Ritse M.","given":"Ritse M.","family":"Mann"}],"recId":"1693145294","name":{"displayForm":["Jan C.M. van Zelst, Tao Tan, Paola Clauser, Angels Domingo, Monique D. Dorrius, Daniel Drieling, Michael Golatta, Francisca Gras, Mathijn de Jong, Ruud Pijnappel, Matthieu J.C.M. Rutten, Nico Karssemeijer, Ritse M. Mann"]},"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"7 February 2018"}],"language":["eng"],"title":[{"title":"Dedicated computer-aided detection software for automated 3D breast ultrasound","subtitle":"an efficient tool for the radiologist in supplemental screening of women with dense breasts","title_sort":"Dedicated computer-aided detection software for automated 3D breast ultrasound"}]} 
SRT |a ZELSTJANCMDEDICATEDC7201