PACIFIC: SiPM readout ASIC for LHCb upgrade

A new 64-channel mixed-signal ASIC is presented: PACIFIC. It was developed in TSMC 130 nm CMOS technology for the readout of the Scintillating Fibre Tracker, as a part of the LHCb upgrade. This detector is based on 250 μ m scintillating fibers readout by custom designed 128-channel silicon photomult...

Full description

Saved in:
Bibliographic Details
Main Authors: Mazorra de Cos, José (Author) , Chanal, Hervé (Author) , Comerma-Montells, Albert (Author) , Gascón Fora, David (Author) , Gómez Fernández, Sergio (Author) , Han, Xiaoxue (Author) , Pillet, Nicolas (Author) , Vandaelle, Richard (Author)
Format: Article (Journal)
Language:English
Published: 2018
In: Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Year: 2017, Volume: 912, Pages: 354-358
ISSN:1872-9576
DOI:10.1016/j.nima.2017.12.044
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.nima.2017.12.044
Verlag, lizenzpflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S0168900217314377
Get full text
Author Notes:José Mazorra de Cos, Hervé Chanal, Albert Comerma Montells, David Gascón Fora, Sergio Gómez Fernández, Xiaoxue Han, Nicolas Pillet, Richard Vandaelle, on behalf of the LHCb Scintillating Fibre Tracker Group

MARC

LEADER 00000caa a2200000 c 4500
001 1693177153
003 DE-627
005 20240405193206.0
007 cr uuu---uuuuu
008 200324r20182017xx |||||o 00| ||eng c
024 7 |a 10.1016/j.nima.2017.12.044  |2 doi 
035 |a (DE-627)1693177153 
035 |a (DE-599)KXP1693177153 
035 |a (OCoLC)1341311010 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Mazorra de Cos, José  |e VerfasserIn  |0 (DE-588)1206944064  |0 (DE-627)1693178850  |4 aut 
245 1 0 |a PACIFIC  |b SiPM readout ASIC for LHCb upgrade  |c José Mazorra de Cos, Hervé Chanal, Albert Comerma Montells, David Gascón Fora, Sergio Gómez Fernández, Xiaoxue Han, Nicolas Pillet, Richard Vandaelle, on behalf of the LHCb Scintillating Fibre Tracker Group 
264 1 |c 2018 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 21 December 2017 
500 |a Gesehen am 24.03.2020 
520 |a A new 64-channel mixed-signal ASIC is presented: PACIFIC. It was developed in TSMC 130 nm CMOS technology for the readout of the Scintillating Fibre Tracker, as a part of the LHCb upgrade. This detector is based on 250 μ m scintillating fibers readout by custom designed 128-channel silicon photomultiplier arrays. It will cover a total area of 340 m2, distributed over the 12 planes that compose it. The sensors are connected directly to PACIFIC without any interface components. The ASIC acquires the current pulses using a current conveyor. A fast double pole-zero cancellation shaper is used to minimize spillover. The charge is then collected using gated integrators, with a twofold interleaved scheme to minimize dead time. The resulting voltage level is digitized with a configurable 2 bit non-linear flash ADC. The output is a 320 Mbps differential signal produced by the serializers, which gather the results from four adjacent channels. 
534 |c 2017 
650 4 |a ASIC 
650 4 |a LHCb 
650 4 |a SiPM 
650 4 |a Tracker 
700 1 |a Chanal, Hervé  |e VerfasserIn  |4 aut 
700 1 |a Comerma-Montells, Albert  |e VerfasserIn  |0 (DE-588)1162561262  |0 (DE-627)1026689686  |0 (DE-576)507494105  |4 aut 
700 1 |a Gascón Fora, David  |e VerfasserIn  |4 aut 
700 1 |a Gómez Fernández, Sergio  |e VerfasserIn  |4 aut 
700 1 |a Han, Xiaoxue  |e VerfasserIn  |0 (DE-588)1162567090  |0 (DE-627)1026694159  |0 (DE-576)507494636  |4 aut 
700 1 |a Pillet, Nicolas  |e VerfasserIn  |4 aut 
700 1 |a Vandaelle, Richard  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment  |d [Amsterdam] : Elsevier, 1984  |g 912(2018), Seite 354-358  |h Online-Ressource  |w (DE-627)266014666  |w (DE-600)1466532-3  |w (DE-576)074959743  |x 1872-9576  |7 nnas  |a PACIFIC SiPM readout ASIC for LHCb upgrade 
773 1 8 |g volume:912  |g year:2018  |g pages:354-358  |g extent:5  |a PACIFIC SiPM readout ASIC for LHCb upgrade 
856 4 0 |u https://doi.org/10.1016/j.nima.2017.12.044  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0168900217314377  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200324 
993 |a Article 
994 |a 2018 
998 |g 1162567090  |a Han, Xiaoxue  |m 1162567090:Han, Xiaoxue  |d 130000  |d 130200  |e 130000PH1162567090  |e 130200PH1162567090  |k 0/130000/  |k 1/130000/130200/  |p 6 
998 |g 1162561262  |a Comerma-Montells, Albert  |m 1162561262:Comerma-Montells, Albert  |d 130000  |d 130200  |e 130000PC1162561262  |e 130200PC1162561262  |k 0/130000/  |k 1/130000/130200/  |p 3 
999 |a KXP-PPN1693177153  |e 3612382225 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedDisp":"2018","dateIssuedKey":"2018"}],"language":["eng"],"physDesc":[{"extent":"5 S."}],"relHost":[{"part":{"pages":"354-358","year":"2018","text":"912(2018), Seite 354-358","extent":"5","volume":"912"},"type":{"media":"Online-Ressource","bibl":"periodical"},"title":[{"title_sort":"Nuclear instruments & methods in physics research","subtitle":"a journal on accelerators, instrumentation and techniques applied to research in nuclear and atomic physics, materials science and related fields in physics","partname":"Accelerators, spectrometers, detectors and associated equipment","title":"Nuclear instruments & methods in physics research"}],"titleAlt":[{"title":"Nuclear instruments & methods in physics research / A"}],"recId":"266014666","id":{"issn":["1872-9576"],"eki":["266014666"],"zdb":["1466532-3"]},"pubHistory":["Nachgewiesen 226.1984 -"],"note":["Gesehen am 24.05.23"],"physDesc":[{"extent":"Online-Ressource"}],"disp":"PACIFIC SiPM readout ASIC for LHCb upgradeNuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment","language":["eng"],"origin":[{"dateIssuedKey":"1994","dateIssuedDisp":"1994-","publisherPlace":"[Amsterdam] ; Amsterdam","publisher":"Elsevier ; North-Holland Publ. Co."}]}],"note":["Available online 21 December 2017","Gesehen am 24.03.2020"],"name":{"displayForm":["José Mazorra de Cos, Hervé Chanal, Albert Comerma Montells, David Gascón Fora, Sergio Gómez Fernández, Xiaoxue Han, Nicolas Pillet, Richard Vandaelle, on behalf of the LHCb Scintillating Fibre Tracker Group"]},"id":{"eki":["1693177153"],"doi":["10.1016/j.nima.2017.12.044"]},"recId":"1693177153","title":[{"title_sort":"PACIFIC","subtitle":"SiPM readout ASIC for LHCb upgrade","title":"PACIFIC"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"family":"Mazorra de Cos","roleDisplay":"VerfasserIn","display":"Mazorra de Cos, José","given":"José","role":"aut"},{"role":"aut","family":"Chanal","roleDisplay":"VerfasserIn","given":"Hervé","display":"Chanal, Hervé"},{"role":"aut","given":"Albert","roleDisplay":"VerfasserIn","display":"Comerma-Montells, Albert","family":"Comerma-Montells"},{"role":"aut","given":"David","roleDisplay":"VerfasserIn","display":"Gascón Fora, David","family":"Gascón Fora"},{"roleDisplay":"VerfasserIn","display":"Gómez Fernández, Sergio","given":"Sergio","family":"Gómez Fernández","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Han, Xiaoxue","given":"Xiaoxue","family":"Han"},{"role":"aut","family":"Pillet","roleDisplay":"VerfasserIn","display":"Pillet, Nicolas","given":"Nicolas"},{"role":"aut","display":"Vandaelle, Richard","roleDisplay":"VerfasserIn","given":"Richard","family":"Vandaelle"}]} 
SRT |a MAZORRADECPACIFIC2018