Comparison of different treatment planning approaches for intensity-modulated proton therapy with simultaneous integrated boost for pancreatic cancer

Background: Neoadjuvant radio(chemo)therapy of non-metastasized, borderline resectable or unresectable locally advanced pancreatic cancer is complex and prone to cause side-effects, e.g., in gastrointestinal organs. Intensity-modulated proton therapy (IMPT) enables a high conformity to the targets w...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Stefanowicz, Sarah (VerfasserIn) , Stützer, Kristin (VerfasserIn) , Zschaeck, Sebastian (VerfasserIn) , Jakobi, Annika (VerfasserIn) , Troost, Esther Gera Cornelia (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 22. November 2018
In: Radiation oncology
Year: 2018, Jahrgang: 13
ISSN:1748-717X
DOI:10.1186/s13014-018-1165-0
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1186/s13014-018-1165-0
Verlag, lizenzpflichtig, Volltext: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6249773/
Volltext
Verfasserangaben:Sarah Stefanowicz, Kristin Stützer, Sebastian Zschaeck, Annika Jakobi and Esther G.C. Troost

MARC

LEADER 00000caa a2200000 c 4500
001 1694300412
003 DE-627
005 20240405193213.0
007 cr uuu---uuuuu
008 200409s2018 xx |||||o 00| ||eng c
024 7 |a 10.1186/s13014-018-1165-0  |2 doi 
035 |a (DE-627)1694300412 
035 |a (DE-599)KXP1694300412 
035 |a (OCoLC)1341314141 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Stefanowicz, Sarah  |e VerfasserIn  |0 (DE-588)1208009478  |0 (DE-627)1694300528  |4 aut 
245 1 0 |a Comparison of different treatment planning approaches for intensity-modulated proton therapy with simultaneous integrated boost for pancreatic cancer  |c Sarah Stefanowicz, Kristin Stützer, Sebastian Zschaeck, Annika Jakobi and Esther G.C. Troost 
264 1 |c 22. November 2018 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 09.04.2020 
520 |a Background: Neoadjuvant radio(chemo)therapy of non-metastasized, borderline resectable or unresectable locally advanced pancreatic cancer is complex and prone to cause side-effects, e.g., in gastrointestinal organs. Intensity-modulated proton therapy (IMPT) enables a high conformity to the targets while simultaneously sparing the normal tissue such that dose-escalation strategies come within reach. In this in silico feasibility study, we compared four IMPT planning strategies including robust multi-field optimization (rMFO) and a simultaneous integrated boost (SIB) for dose-escalation in pancreatic cancer patients. Methods: For six pancreatic cancer patients referred for adjuvant or primary radiochemotherapy, four rMFO-IMPT-SIB treatment plans each, consisting of two or three (non-)coplanar beam arrangements, were optimized. Dose values for both targets, i.e., the elective clinical target volume [CTV, prescribed dose Dpres = 51Gy(RBE)] and the boost target [Dpres = 66Gy(RBE)], for the organs at risk as well as target conformity and homogeneity indexes, derived from the dose volume histograms, were statistically compared. Results: All treatment plans of each strategy fulfilled the prescribed doses to the targets (Dpres(GTV,CTV) = 100%, D95%,(GTV,CTV) ≥ 95%, D2%,(GTV,CTV) ≤ 107%). No significant differences for the conformity index were found (p > 0.05), however, treatment plans with a three non-coplanar beam strategy were most homogenous to both targets (p < 0.045). The median value of all dosimetric results of the large and small bowel as well as for the liver and the spinal cord met the dose constraints with all beam arrangements. Irrespective of the planning strategies, the dose constraint for the duodenum and stomach were not met. Using the three-beam arrangements, the dose to the left kidney could be significant decreased when compared to a two-beam strategy (p < 0.045). Conclusion: Based on our findings we recommend a three-beam configuration with at least one non-coplanar beam for dose-escalated SIB with rMFO-IMPT in advanced pancreatic cancer patients achieving a homogeneous dose distribution in the target while simultaneously minimizing the dose to the organs at risk. Further treatment planning studies on aspects of breathing and organ motion need to be performed. Electronic supplementary material - The online version of this article (10.1186/s13014-018-1165-0) contains supplementary material, which is available to authorized users. 
700 1 |a Stützer, Kristin  |d 1982-  |e VerfasserIn  |0 (DE-588)1047433389  |0 (DE-627)778296342  |0 (DE-576)401023877  |4 aut 
700 1 |a Zschaeck, Sebastian  |e VerfasserIn  |4 aut 
700 1 |a Jakobi, Annika  |e VerfasserIn  |4 aut 
700 1 |a Troost, Esther Gera Cornelia  |d 1978-  |e VerfasserIn  |0 (DE-588)135713250  |0 (DE-627)570561221  |0 (DE-576)300603169  |4 aut 
773 0 8 |i Enthalten in  |t Radiation oncology  |d London : BioMed Central, 2006  |g 13(2018) Artikel-Nummer 228, 11 Seiten  |h Online-Ressource  |w (DE-627)508725739  |w (DE-600)2224965-5  |w (DE-576)260614815  |x 1748-717X  |7 nnas  |a Comparison of different treatment planning approaches for intensity-modulated proton therapy with simultaneous integrated boost for pancreatic cancer 
773 1 8 |g volume:13  |g year:2018  |a Comparison of different treatment planning approaches for intensity-modulated proton therapy with simultaneous integrated boost for pancreatic cancer 
856 4 0 |u https://doi.org/10.1186/s13014-018-1165-0  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6249773/  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200409 
993 |a Article 
994 |a 2018 
998 |g 135713250  |a Troost, Esther Gera Cornelia  |m 135713250:Troost, Esther Gera Cornelia  |p 5  |y j 
998 |g 1047433389  |a Stützer, Kristin  |m 1047433389:Stützer, Kristin  |p 2 
999 |a KXP-PPN1694300412  |e 3621016619 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title":"Comparison of different treatment planning approaches for intensity-modulated proton therapy with simultaneous integrated boost for pancreatic cancer","title_sort":"Comparison of different treatment planning approaches for intensity-modulated proton therapy with simultaneous integrated boost for pancreatic cancer"}],"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"22. November 2018"}],"id":{"doi":["10.1186/s13014-018-1165-0"],"eki":["1694300412"]},"person":[{"given":"Sarah","family":"Stefanowicz","role":"aut","display":"Stefanowicz, Sarah","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","display":"Stützer, Kristin","role":"aut","family":"Stützer","given":"Kristin"},{"given":"Sebastian","family":"Zschaeck","role":"aut","display":"Zschaeck, Sebastian","roleDisplay":"VerfasserIn"},{"given":"Annika","family":"Jakobi","role":"aut","display":"Jakobi, Annika","roleDisplay":"VerfasserIn"},{"display":"Troost, Esther Gera Cornelia","roleDisplay":"VerfasserIn","role":"aut","family":"Troost","given":"Esther Gera Cornelia"}],"name":{"displayForm":["Sarah Stefanowicz, Kristin Stützer, Sebastian Zschaeck, Annika Jakobi and Esther G.C. Troost"]},"note":["Gesehen am 09.04.2020"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1694300412","language":["eng"],"relHost":[{"part":{"volume":"13","text":"13(2018) Artikel-Nummer 228, 11 Seiten","year":"2018"},"pubHistory":["1.2006 -"],"language":["eng"],"recId":"508725739","type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Comparison of different treatment planning approaches for intensity-modulated proton therapy with simultaneous integrated boost for pancreatic cancerRadiation oncology","note":["Gesehen am 06.09.10"],"title":[{"title":"Radiation oncology","title_sort":"Radiation oncology"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["1748-717X"],"zdb":["2224965-5"],"eki":["508725739"]},"origin":[{"publisherPlace":"London","publisher":"BioMed Central","dateIssuedKey":"2006","dateIssuedDisp":"2006-"}]}]} 
SRT |a STEFANOWICCOMPARISON2220