EEG with a reduced number of electrodes: where to detect and how to improve visually, auditory and somatosensory evoked potentials

The measurement of evoked potentials has become a standard tool to test new hardware and software for electroencephalography (EEG). In this study, we investigate where to detect and how to improve visually, auditory and somatosensory evoked potentials with a reduced number of electrodes. We measured...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Stehlin, Sebastian (VerfasserIn) , Nguyen, Xuan Phuc (VerfasserIn) , Niemz, Markolf H. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 13 June 2018
In: Biocybernetics and biomedical engineering
Year: 2018, Jahrgang: 38, Heft: 3, Pages: 700-707
ISSN:2391-467X
DOI:10.1016/j.bbe.2018.06.001
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.bbe.2018.06.001
Verlag, lizenzpflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S0208521618300184
Volltext
Verfasserangaben:Sebastian A.F. Stehlin, Xuan P. Nguyen, Markolf H. Niemz

MARC

LEADER 00000caa a2200000 c 4500
001 1694326713
003 DE-627
005 20220818034806.0
007 cr uuu---uuuuu
008 200409s2018 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.bbe.2018.06.001  |2 doi 
035 |a (DE-627)1694326713 
035 |a (DE-599)KXP1694326713 
035 |a (OCoLC)1341314338 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Stehlin, Sebastian  |e VerfasserIn  |0 (DE-588)1208029134  |0 (DE-627)1694327604  |4 aut 
245 1 0 |a EEG with a reduced number of electrodes  |b where to detect and how to improve visually, auditory and somatosensory evoked potentials  |c Sebastian A.F. Stehlin, Xuan P. Nguyen, Markolf H. Niemz 
264 1 |c 13 June 2018 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 09.04.2020 
520 |a The measurement of evoked potentials has become a standard tool to test new hardware and software for electroencephalography (EEG). In this study, we investigate where to detect and how to improve visually, auditory and somatosensory evoked potentials with a reduced number of electrodes. We measured a total of 50 evoked potentials in healthy subjects, and we were able to detect visually, auditory and somatosensory evoked potentials with just three electrodes. We also investigated where to measure a combination of visually, auditory and somatosensory evoked potentials and found the best positions to be Oz, O1, O2, TP9 and TP10. In the second part of this study, we analyzed how the evoked potentials depend on the segmentation frequency selected to superpose EEG responses. We found that the detection of visually evoked potentials requires the segmentation frequency to match the stimulus frequency with an accuracy of at least 99.92 percent. The detection of auditory evoked potentials and somatosensory evoked potentials requires a matching of at least 99.95 percent. Therefore, a correct matching of the segmentation frequency with the stimulation frequency is the primary key to improving the quality of evoked potentials. 
650 4 |a 10-20 system 
650 4 |a AEP 
650 4 |a EEG 
650 4 |a Evoked potentials 
650 4 |a SEP 
650 4 |a VEP 
700 1 |a Nguyen, Xuan Phuc  |d 1965-  |e VerfasserIn  |0 (DE-588)124801412  |0 (DE-627)366429299  |0 (DE-576)294510044  |4 aut 
700 1 |a Niemz, Markolf H.  |d 1964-  |e VerfasserIn  |0 (DE-588)112742181  |0 (DE-627)516067095  |0 (DE-576)169105261  |4 aut 
773 0 8 |i Enthalten in  |t Biocybernetics and biomedical engineering  |d Amsterdam [u.a.] : Elsevier, 2011  |g 38(2018), 3, Seite 700-707  |h Online-Ressource  |w (DE-627)77590466X  |w (DE-600)2747541-4  |w (DE-576)402166531  |x 2391-467X  |7 nnas  |a EEG with a reduced number of electrodes where to detect and how to improve visually, auditory and somatosensory evoked potentials 
773 1 8 |g volume:38  |g year:2018  |g number:3  |g pages:700-707  |g extent:8  |a EEG with a reduced number of electrodes where to detect and how to improve visually, auditory and somatosensory evoked potentials 
856 4 0 |u https://doi.org/10.1016/j.bbe.2018.06.001  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0208521618300184  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200409 
993 |a Article 
994 |a 2018 
998 |g 1208029134  |a Stehlin, Sebastian  |m 1208029134:Stehlin, Sebastian  |d 60000  |d 69020  |e 60000PS1208029134  |e 69020PS1208029134  |k 0/60000/  |k 1/60000/69020/  |p 1  |x j 
998 |g 112742181  |a Niemz, Markolf H.  |m 112742181:Niemz, Markolf H.  |d 60000  |d 69020  |e 60000PN112742181  |e 69020PN112742181  |k 0/60000/  |k 1/60000/69020/  |p 3  |y j 
998 |g 124801412  |a Nguyen, Xuan Phuc  |m 124801412:Nguyen, Xuan Phuc  |d 60000  |d 69020  |e 60000PN124801412  |e 69020PN124801412  |k 0/60000/  |k 1/60000/69020/  |p 2 
999 |a KXP-PPN1694326713  |e 3621142541 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"13 June 2018"}],"id":{"doi":["10.1016/j.bbe.2018.06.001"],"eki":["1694326713"]},"name":{"displayForm":["Sebastian A.F. Stehlin, Xuan P. Nguyen, Markolf H. Niemz"]},"physDesc":[{"extent":"8 S."}],"relHost":[{"id":{"issn":["2391-467X"],"eki":["77590466X"],"zdb":["2747541-4"]},"origin":[{"dateIssuedDisp":"2011-","dateIssuedKey":"2011","publisher":"Elsevier","publisherPlace":"Amsterdam [u.a.]"}],"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Biocybernetics and biomedical engineering","title_sort":"Biocybernetics and biomedical engineering"}],"recId":"77590466X","language":["eng"],"note":["Gesehen am 02.01.14","Fortsetzung der Druck-Ausgabe"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"EEG with a reduced number of electrodes where to detect and how to improve visually, auditory and somatosensory evoked potentialsBiocybernetics and biomedical engineering","part":{"extent":"8","volume":"38","text":"38(2018), 3, Seite 700-707","pages":"700-707","issue":"3","year":"2018"},"pubHistory":["Nachgewiesen 31.2011 -"]}],"title":[{"subtitle":"where to detect and how to improve visually, auditory and somatosensory evoked potentials","title":"EEG with a reduced number of electrodes","title_sort":"EEG with a reduced number of electrodes"}],"person":[{"given":"Sebastian","family":"Stehlin","role":"aut","roleDisplay":"VerfasserIn","display":"Stehlin, Sebastian"},{"family":"Nguyen","given":"Xuan Phuc","display":"Nguyen, Xuan Phuc","roleDisplay":"VerfasserIn","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Niemz, Markolf H.","given":"Markolf H.","family":"Niemz"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 09.04.2020"],"recId":"1694326713","language":["eng"]} 
SRT |a STEHLINSEBEEGWITHARE1320