Demineralization detection in orthodontics using an ophthalmic optical coherence tomography device equipped with a multicolor fluorescence module

Demineralizations such as white spot lesions are among the most prevalent side effects during orthodontic treatment. Fluorescence devices, including quantitative light-induced fluorescence (QLF), exploiting the intrinsic fluorescence of enamel and teeth and most recently optical coherence tomography...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Şen, Sinan (VerfasserIn) , Erber, Ralf (VerfasserIn) , Orhan, Gül (VerfasserIn) , Lux, Christopher J. (VerfasserIn) , Zingler, Sebastian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 17 December 2019
In: Clinical oral investigations
Year: 2019, Jahrgang: 23, Heft: 8, Pages: 2579-2590
ISSN:1436-3771
DOI:10.1007/s00784-019-03116-3
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s00784-019-03116-3
Volltext
Verfasserangaben:Sinan Şen, Ralf Erber, Nadine Deurer, Gül Orhan, Christopher J. Lux, Sebastian Zingler

MARC

LEADER 00000caa a2200000 c 4500
001 1694478912
003 DE-627
005 20220818040256.0
007 cr uuu---uuuuu
008 200414s2019 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00784-019-03116-3  |2 doi 
035 |a (DE-627)1694478912 
035 |a (DE-599)KXP1694478912 
035 |a (OCoLC)1341314654 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Şen, Sinan  |d 1986-  |e VerfasserIn  |0 (DE-588)1082311049  |0 (DE-627)847302989  |0 (DE-576)455334501  |4 aut 
245 1 0 |a Demineralization detection in orthodontics using an ophthalmic optical coherence tomography device equipped with a multicolor fluorescence module  |c Sinan Şen, Ralf Erber, Nadine Deurer, Gül Orhan, Christopher J. Lux, Sebastian Zingler 
264 1 |c 17 December 2019 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 18.11.2021 
520 |a Demineralizations such as white spot lesions are among the most prevalent side effects during orthodontic treatment. Fluorescence devices, including quantitative light-induced fluorescence (QLF), exploiting the intrinsic fluorescence of enamel and teeth and most recently optical coherence tomography (OCT) were introduced for early demineralization detection. In addition to near-infrared OCT scanning, multicolor modules allow for imaging with different laser wavelengths and the detection of reflective- and fluorescent light. The aim of this study was to evaluate a modified multicolor ophthalmic OCT device for the detection of early carious lesions in vitro and in vivo. 
700 1 |a Erber, Ralf  |d 1967-  |e VerfasserIn  |0 (DE-588)136076572  |0 (DE-627)69405433X  |0 (DE-576)285643452  |4 aut 
700 1 |a Orhan, Gül  |d 1989-  |e VerfasserIn  |0 (DE-588)1196033811  |0 (DE-627)1677907622  |4 aut 
700 1 |a Lux, Christopher J.  |d 1969-  |e VerfasserIn  |0 (DE-588)121600114  |0 (DE-627)081413815  |0 (DE-576)292792549  |4 aut 
700 1 |a Zingler, Sebastian  |d 1976-  |e VerfasserIn  |0 (DE-588)143211390  |0 (DE-627)704421933  |0 (DE-576)335662706  |4 aut 
773 0 8 |i Enthalten in  |t Clinical oral investigations  |d Berlin : Springer, 1997  |g 23(2019), 8, Seite 2579-2590  |h Online-Ressource  |w (DE-627)268756139  |w (DE-600)1472578-2  |w (DE-576)09448029X  |x 1436-3771  |7 nnas  |a Demineralization detection in orthodontics using an ophthalmic optical coherence tomography device equipped with a multicolor fluorescence module 
773 1 8 |g volume:23  |g year:2019  |g number:8  |g pages:2579-2590  |g extent:12  |a Demineralization detection in orthodontics using an ophthalmic optical coherence tomography device equipped with a multicolor fluorescence module 
856 4 0 |u https://doi.org/10.1007/s00784-019-03116-3  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200414 
993 |a Article 
994 |a 2019 
998 |g 143211390  |a Zingler, Sebastian  |m 143211390:Zingler, Sebastian  |d 910000  |d 910800  |e 910000PZ143211390  |e 910800PZ143211390  |k 0/910000/  |k 1/910000/910800/  |p 6  |y j 
998 |g 121600114  |a Lux, Christopher J.  |m 121600114:Lux, Christopher J.  |d 910000  |d 910800  |e 910000PL121600114  |e 910800PL121600114  |k 0/910000/  |k 1/910000/910800/  |p 5 
998 |g 1196033811  |a Orhan, Gül  |m 1196033811:Orhan, Gül  |d 50000  |e 50000PO1196033811  |k 0/50000/  |p 4 
998 |g 136076572  |a Erber, Ralf  |m 136076572:Erber, Ralf  |d 910000  |d 910800  |e 910000PE136076572  |e 910800PE136076572  |k 0/910000/  |k 1/910000/910800/  |p 2 
998 |g 1082311049  |a Şen, Sinan  |m 1082311049:Şen, Sinan  |d 910000  |d 910800  |e 910000PS1082311049  |e 910800PS1082311049  |k 0/910000/  |k 1/910000/910800/  |p 1  |x j 
999 |a KXP-PPN1694478912  |e 3623025348 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Sinan Şen, Ralf Erber, Nadine Deurer, Gül Orhan, Christopher J. Lux, Sebastian Zingler"]},"note":["Gesehen am 18.11.2021"],"recId":"1694478912","id":{"doi":["10.1007/s00784-019-03116-3"],"eki":["1694478912"]},"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedKey":"2019","dateIssuedDisp":"17 December 2019"}],"title":[{"title_sort":"Demineralization detection in orthodontics using an ophthalmic optical coherence tomography device equipped with a multicolor fluorescence module","title":"Demineralization detection in orthodontics using an ophthalmic optical coherence tomography device equipped with a multicolor fluorescence module"}],"person":[{"role":"aut","display":"Şen, Sinan","family":"Şen","given":"Sinan"},{"role":"aut","family":"Erber","display":"Erber, Ralf","given":"Ralf"},{"family":"Orhan","display":"Orhan, Gül","given":"Gül","role":"aut"},{"role":"aut","display":"Lux, Christopher J.","family":"Lux","given":"Christopher J."},{"display":"Zingler, Sebastian","family":"Zingler","given":"Sebastian","role":"aut"}],"physDesc":[{"extent":"12 S."}],"relHost":[{"pubHistory":["1.1997 -"],"recId":"268756139","note":["Gesehen am 27.10.04"],"disp":"Demineralization detection in orthodontics using an ophthalmic optical coherence tomography device equipped with a multicolor fluorescence moduleClinical oral investigations","part":{"year":"2019","extent":"12","issue":"8","volume":"23","pages":"2579-2590","text":"23(2019), 8, Seite 2579-2590"},"title":[{"title_sort":"Clinical oral investigations","subtitle":"Organ of: Deutsche Gesellschaft für Zahn-, Mund- und Kieferheilkunde","title":"Clinical oral investigations"}],"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisher":"Springer","dateIssuedKey":"1997","publisherPlace":"Berlin ; Heidelberg","dateIssuedDisp":"1997-"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"id":{"eki":["268756139"],"issn":["1436-3771"],"zdb":["1472578-2"]},"language":["eng"]}]} 
SRT |a SENSINANERDEMINERALI1720