Development and validation of single field multi-ion particle therapy treatments
<h3>Purpose</h3><p>To develop and validate combined ion-beam with constant relative biological effectiveness (RBE) (CICR) particle therapy in single field arrangements for improved treatment efficacy, robustness, and normal tissue sparing.</p><h3>Methods and Materials&l...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2020
|
| In: |
International journal of radiation oncology, biology, physics
Year: 2019, Jahrgang: 106, Heft: 1, Pages: 194-205 |
| ISSN: | 1879-355X |
| DOI: | 10.1016/j.ijrobp.2019.10.008 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ijrobp.2019.10.008 Verlag, lizenzpflichtig, Volltext: https://www.redjournal.org/article/S0360-3016(19)33879-9/abstract |
| Verfasserangaben: | Benedikt Kopp, Stewart Mein, Ivana Dokic, Semi Harrabi, Till Tobias Böhlen, Thomas Haberer, Jürgen Debus, Amir Abdollahi, Andrea Mairani |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1694557731 | ||
| 003 | DE-627 | ||
| 005 | 20220818041208.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200415r20202019xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.ijrobp.2019.10.008 |2 doi | |
| 035 | |a (DE-627)1694557731 | ||
| 035 | |a (DE-599)KXP1694557731 | ||
| 035 | |a (OCoLC)1341315060 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Kopp, Benedikt |d 1990- |e VerfasserIn |0 (DE-588)1170097081 |0 (DE-627)1037079787 |0 (DE-576)512373809 |4 aut | |
| 245 | 1 | 0 | |a Development and validation of single field multi-ion particle therapy treatments |c Benedikt Kopp, Stewart Mein, Ivana Dokic, Semi Harrabi, Till Tobias Böhlen, Thomas Haberer, Jürgen Debus, Amir Abdollahi, Andrea Mairani |
| 264 | 1 | |c 2020 | |
| 300 | |a 12 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Published online: October 11, 2019 | ||
| 500 | |a Gesehen am 15.04.2020 | ||
| 520 | |a <h3>Purpose</h3><p>To develop and validate combined ion-beam with constant relative biological effectiveness (RBE) (CICR) particle therapy in single field arrangements for improved treatment efficacy, robustness, and normal tissue sparing.</p><h3>Methods and Materials</h3><p>The PRECISE (PaRticle thErapy using single and Combined Ion optimization StratEgies) treatment planning system was developed to investigate clinical viability of CICR treatments. Single-field uniform dose (SFUD) with a single ion (proton [p], helium [He], or carbon [C]) and CICR (C-p and C-He) treatments were generated for 3 patient cases with a clinically prescribed dose of 3 Gy (RBE) per fraction. Spread-out Bragg peak plans were irradiated in homogenous and clinical-like settings using an anthropomorphic head phantom. A dosimetric and biological verification of CICR<sub>C-p</sub> treatments using a murine glioma cell line (GL261) was performed.</p><h3>Results</h3><p>CICR treatment plans for the 3 patients presented highly uniform physical dose while reducing high dose-averaged linear energy transfer gradients compared with carbon ions alone. When considering uncertainty in tissue parameter (α/β)<sub>x</sub> assignment and RBE modeling, the CICR<sub>C-p</sub> treatment exhibited enhanced biophysical stability within the target volume, similar to protons alone. CICR treatments reduced dose to normal tissue surrounding the target, exhibiting similar or improved dosimetric features compared with SFUD<sub>He</sub>. For both CICR<sub>C-p</sub> and SFUD treatments, measurements verified the planned dose in the target within ∼3%. Planned versus measured target RBE values were 1.38 ± 0.02 and 1.39 ± 0.07 (<1% deviation), respectively, for the CICR<sub>C-p</sub> treatment in heterogenous settings.</p><h3>Conclusions</h3><p>Here, we demonstrate that by combining 2 (or more) ions in a single field arrangement, more robust biological and more conformal dose distributions can be delivered compared with conventional particle therapy treatment planning. This work constitutes the first dosimetric and biological verification of multi-ion particle therapy in homogeneous as well as heterogenous settings.</p> | ||
| 534 | |c 2019 | ||
| 700 | 1 | |a Mein, Stewart |d 1989- |e VerfasserIn |0 (DE-588)1156925304 |0 (DE-627)1019871873 |0 (DE-576)502506105 |4 aut | |
| 700 | 1 | |a Dokić, Ivana |e VerfasserIn |0 (DE-588)1024109208 |0 (DE-627)719434378 |0 (DE-576)367945789 |4 aut | |
| 700 | 1 | |a Harrabi, Semi B. |d 1986- |e VerfasserIn |0 (DE-588)1044730161 |0 (DE-627)772596034 |0 (DE-576)398081298 |4 aut | |
| 700 | 1 | |a Böhlen, Till Tobias |e VerfasserIn |4 aut | |
| 700 | 1 | |a Haberer, Thomas |d 1960- |e VerfasserIn |0 (DE-588)123579198 |0 (DE-627)706353714 |0 (DE-576)214902188 |4 aut | |
| 700 | 1 | |a Debus, Jürgen |d 1964- |e VerfasserIn |0 (DE-588)1022671421 |0 (DE-627)717025780 |0 (DE-576)365774944 |4 aut | |
| 700 | 1 | |a Abdollahi, Amir |e VerfasserIn |0 (DE-588)129612715 |0 (DE-627)474757765 |0 (DE-576)297748874 |4 aut | |
| 700 | 1 | |a Mairani, Andrea |e VerfasserIn |0 (DE-588)1116742179 |0 (DE-627)870669281 |0 (DE-576)478592493 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t International journal of radiation oncology, biology, physics |d Amsterdam [u.a.] : Elsevier Science, 1975 |g 106(2020), 1, Seite 194-205 |h Online-Ressource |w (DE-627)306659662 |w (DE-600)1500486-7 |w (DE-576)081986319 |x 1879-355X |7 nnas |a Development and validation of single field multi-ion particle therapy treatments |
| 773 | 1 | 8 | |g volume:106 |g year:2020 |g number:1 |g pages:194-205 |g extent:12 |a Development and validation of single field multi-ion particle therapy treatments |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.ijrobp.2019.10.008 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.redjournal.org/article/S0360-3016(19)33879-9/abstract |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200415 | ||
| 993 | |a Article | ||
| 994 | |a 2020 | ||
| 998 | |g 1116742179 |a Mairani, Andrea |m 1116742179:Mairani, Andrea |d 910000 |d 950000 |d 950400 |e 910000PM1116742179 |e 950000PM1116742179 |e 950400PM1116742179 |k 0/910000/ |k 1/910000/950000/ |k 2/910000/950000/950400/ |p 9 |y j | ||
| 998 | |g 129612715 |a Abdollahi, Amir |m 129612715:Abdollahi, Amir |d 910000 |d 911400 |e 910000PA129612715 |e 911400PA129612715 |k 0/910000/ |k 1/910000/911400/ |p 8 | ||
| 998 | |g 1022671421 |a Debus, Jürgen |m 1022671421:Debus, Jürgen |d 910000 |d 911400 |e 910000PD1022671421 |e 911400PD1022671421 |k 0/910000/ |k 1/910000/911400/ |p 7 | ||
| 998 | |g 123579198 |a Haberer, Thomas |m 123579198:Haberer, Thomas |d 910000 |d 950000 |d 950400 |e 910000PH123579198 |e 950000PH123579198 |e 950400PH123579198 |k 0/910000/ |k 1/910000/950000/ |k 2/910000/950000/950400/ |p 6 | ||
| 998 | |g 1044730161 |a Harrabi, Semi B. |m 1044730161:Harrabi, Semi B. |d 910000 |d 911400 |e 910000PH1044730161 |e 911400PH1044730161 |k 0/910000/ |k 1/910000/911400/ |p 4 | ||
| 998 | |g 1024109208 |a Dokić, Ivana |m 1024109208:Dokić, Ivana |d 910000 |d 911400 |e 910000PD1024109208 |e 911400PD1024109208 |k 0/910000/ |k 1/910000/911400/ |p 3 | ||
| 998 | |g 1156925304 |a Mein, Stewart |m 1156925304:Mein, Stewart |d 130000 |e 130000PM1156925304 |k 0/130000/ |p 2 | ||
| 998 | |g 1170097081 |a Kopp, Benedikt |m 1170097081:Kopp, Benedikt |d 910000 |d 911400 |e 910000PK1170097081 |e 911400PK1170097081 |k 0/910000/ |k 1/910000/911400/ |p 1 |x j | ||
| 999 | |a KXP-PPN1694557731 |e 3623558397 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["1500486-7"],"eki":["306659662"],"issn":["1879-355X"]},"title":[{"title":"International journal of radiation oncology, biology, physics","subtitle":"the official journal of the American Society for Therapeutic Radiology and Oncology","title_sort":"International journal of radiation oncology, biology, physics"}],"origin":[{"dateIssuedDisp":"1975-","publisher":"Elsevier Science","publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1975"}],"recId":"306659662","disp":"Development and validation of single field multi-ion particle therapy treatmentsInternational journal of radiation oncology, biology, physics","type":{"bibl":"periodical","media":"Online-Ressource"},"part":{"extent":"12","pages":"194-205","issue":"1","text":"106(2020), 1, Seite 194-205","volume":"106","year":"2020"},"language":["eng"],"pubHistory":["1.1975/76 -"],"note":["Gesehen am 15.01.20","Ungezählte Beil.: Supplement"]}],"origin":[{"dateIssuedDisp":"2020","dateIssuedKey":"2020"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title_sort":"Development and validation of single field multi-ion particle therapy treatments","title":"Development and validation of single field multi-ion particle therapy treatments"}],"id":{"doi":["10.1016/j.ijrobp.2019.10.008"],"eki":["1694557731"]},"physDesc":[{"extent":"12 S."}],"person":[{"display":"Kopp, Benedikt","given":"Benedikt","family":"Kopp","role":"aut"},{"display":"Mein, Stewart","given":"Stewart","role":"aut","family":"Mein"},{"role":"aut","family":"Dokić","given":"Ivana","display":"Dokić, Ivana"},{"given":"Semi B.","display":"Harrabi, Semi B.","family":"Harrabi","role":"aut"},{"given":"Till Tobias","display":"Böhlen, Till Tobias","family":"Böhlen","role":"aut"},{"given":"Thomas","display":"Haberer, Thomas","family":"Haberer","role":"aut"},{"given":"Jürgen","display":"Debus, Jürgen","family":"Debus","role":"aut"},{"given":"Amir","display":"Abdollahi, Amir","family":"Abdollahi","role":"aut"},{"role":"aut","family":"Mairani","given":"Andrea","display":"Mairani, Andrea"}],"recId":"1694557731","note":["Published online: October 11, 2019","Gesehen am 15.04.2020"],"name":{"displayForm":["Benedikt Kopp, Stewart Mein, Ivana Dokic, Semi Harrabi, Till Tobias Böhlen, Thomas Haberer, Jürgen Debus, Amir Abdollahi, Andrea Mairani"]},"language":["eng"]} | ||
| SRT | |a KOPPBENEDIDEVELOPMEN2020 | ||