Reliability of a new symptom score in a titrated quantitative conjunctival provocation test supported by an objective photodocumentation
Background: Allergen provocation tests are useful methods for proving the clinical relevance of an allergen-specific sensitization. Among these methods, the conjunctival provocation test (CPT) represents an easy-to-use tool. However, its readout parameters have not yet been internationally standardi...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
2018
|
| In: |
International archives of allergy and immunology
Year: 2018, Volume: 176, Issue: 3-4, Pages: 215-224 |
| ISSN: | 1423-0097 |
| DOI: | 10.1159/000487884 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1159/000487884 Verlag, lizenzpflichtig, Volltext: https://www.karger.com/Article/FullText/487884 |
| Author Notes: | Oliver Pfaar, Dan Philipp Claßen, Anatoli Astvatsatourov, Ludger Klimek, Ralph Mösges |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1694961745 | ||
| 003 | DE-627 | ||
| 005 | 20220818044249.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200420s2018 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1159/000487884 |2 doi | |
| 035 | |a (DE-627)1694961745 | ||
| 035 | |a (DE-599)KXP1694961745 | ||
| 035 | |a (OCoLC)1341315720 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Pfaar, Oliver |d 1972- |e VerfasserIn |0 (DE-588)12385900X |0 (DE-627)706454049 |0 (DE-576)293913099 |4 aut | |
| 245 | 1 | 0 | |a Reliability of a new symptom score in a titrated quantitative conjunctival provocation test supported by an objective photodocumentation |c Oliver Pfaar, Dan Philipp Claßen, Anatoli Astvatsatourov, Ludger Klimek, Ralph Mösges |
| 264 | 1 | |c 2018 | |
| 300 | |a 10 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 20.04.2020 | ||
| 520 | |a Background: Allergen provocation tests are useful methods for proving the clinical relevance of an allergen-specific sensitization. Among these methods, the conjunctival provocation test (CPT) represents an easy-to-use tool. However, its readout parameters have not yet been internationally standardized or validated. Photodocumentation has been shown as a good option for objectifying a CPT reaction, supporting the local investigator assessment. Based on test-retest reliability of the score and an objective digital photoanalysis of the conjunctival redness, this study aimed to prove the reproducibility of a new CPT scoring system for use in clinical trials (ClinicalTrials.gov identifier: NCT02690740). Methods: A titrated quantitative CPT was conducted outside of the pollen season in a final cohort of 23 adult patients with birch or grass pollen-induced allergic rhinoconjunctivitis. Conjunctival symptoms were analyzed using a standardized symptom score. Conjunctival redness was also evaluated by an external observer and correlated with a digital photoanalysis using MATLAB software. Results: A test-retest correlation of 0.6 (p < 0.01) was found for the symptom score results. Likewise, a correlation of 0.65 (p < 0.01) was observed in the digital photoanalysis. The total symptom score showed a decrease in the mean value of 0.48 score points in the retest. Conclusions: This study reveals both a valuable test-retest correlation of the proposed score as well as a good correlation of eye redness with the (objective) photodocumentation. Based on our results, we can recommend the use of this scoring system as a valuable clinical protocol for future clinical trials. | ||
| 700 | 1 | |a Claßen, Dan Philipp |d 1988- |e VerfasserIn |0 (DE-588)1191702111 |0 (DE-627)1670158063 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t International archives of allergy and immunology |d Basel : Karger, 1992 |g 176(2018), 3-4, Seite 215-224 |h Online-Ressource |w (DE-627)300591829 |w (DE-600)1482722-0 |w (DE-576)273877682 |x 1423-0097 |7 nnas |a Reliability of a new symptom score in a titrated quantitative conjunctival provocation test supported by an objective photodocumentation |
| 773 | 1 | 8 | |g volume:176 |g year:2018 |g number:3-4 |g pages:215-224 |g extent:10 |a Reliability of a new symptom score in a titrated quantitative conjunctival provocation test supported by an objective photodocumentation |
| 856 | 4 | 0 | |u https://doi.org/10.1159/000487884 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.karger.com/Article/FullText/487884 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200420 | ||
| 993 | |a Article | ||
| 994 | |a 2018 | ||
| 998 | |g 1191702111 |a Claßen, Dan Philipp |m 1191702111:Claßen, Dan Philipp |d 60000 |d 62100 |e 60000PC1191702111 |e 62100PC1191702111 |k 0/60000/ |k 1/60000/62100/ |p 2 | ||
| 998 | |g 12385900X |a Pfaar, Oliver |m 12385900X:Pfaar, Oliver |d 60000 |d 62100 |e 60000PP12385900X |e 62100PP12385900X |k 0/60000/ |k 1/60000/62100/ |p 1 |x j | ||
| 999 | |a KXP-PPN1694961745 |e 3626990729 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"language":["eng"],"recId":"1694961745","type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 20.04.2020"],"person":[{"given":"Oliver","family":"Pfaar","role":"aut","display":"Pfaar, Oliver","roleDisplay":"VerfasserIn"},{"family":"Claßen","given":"Dan Philipp","display":"Claßen, Dan Philipp","roleDisplay":"VerfasserIn","role":"aut"}],"title":[{"title":"Reliability of a new symptom score in a titrated quantitative conjunctival provocation test supported by an objective photodocumentation","title_sort":"Reliability of a new symptom score in a titrated quantitative conjunctival provocation test supported by an objective photodocumentation"}],"relHost":[{"id":{"eki":["300591829"],"zdb":["1482722-0"],"issn":["1423-0097"]},"origin":[{"publisher":"Karger","dateIssuedKey":"1992","dateIssuedDisp":"1992-","publisherPlace":"Basel"}],"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"International archives of allergy and immunology","subtitle":"official journal of the Collegium Internationale Allergologicum","title":"International archives of allergy and immunology"}],"recId":"300591829","language":["eng"],"note":["Gesehen am 09.01.2019"],"disp":"Reliability of a new symptom score in a titrated quantitative conjunctival provocation test supported by an objective photodocumentationInternational archives of allergy and immunology","type":{"bibl":"periodical","media":"Online-Ressource"},"titleAlt":[{"title":"Allergy and immunology"}],"part":{"year":"2018","issue":"3-4","pages":"215-224","text":"176(2018), 3-4, Seite 215-224","volume":"176","extent":"10"},"pubHistory":["97.1992 -"]}],"physDesc":[{"extent":"10 S."}],"name":{"displayForm":["Oliver Pfaar, Dan Philipp Claßen, Anatoli Astvatsatourov, Ludger Klimek, Ralph Mösges"]},"id":{"doi":["10.1159/000487884"],"eki":["1694961745"]},"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"2018"}]} | ||
| SRT | |a PFAAROLIVERELIABILIT2018 | ||