Comparison of planned dose on different CT image sets to four-dimensional Monte Carlo dose recalculation using the patient's actual breathing trace for lung stereotactic body radiation therapy

Purpose The need for four-dimensional (4D) treatment planning becomes indispensable when it comes to radiation therapy for moving tumors in the thoracic and abdominal regions. The primary purpose of this study is to combine the actual breathing trace during each individual treatment fraction with th...

Full description

Saved in:
Bibliographic Details
Main Authors: Freislederer, Philipp (Author) , Münchow, Asmus von (Author) , Kamp, Florian (Author) , Heinz, Christian (Author) , Gerum, Sabine (Author) , Corradini, Stefanie (Author) , Söhn, Matthias (Author) , Reiner, Michael (Author) , Röder, Falk (Author) , Floca, Ralf (Author) , Alber, Markus (Author) , Belka, Claus (Author) , Parodi, Katia (Author)
Format: Article (Journal)
Language:English
Published: 10 May 2019
In: Medical physics
Year: 2019, Volume: 46, Issue: 7, Pages: 3268-3277
ISSN:2473-4209
DOI:10.1002/mp.13579
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1002/mp.13579
Verlag, lizenzpflichtig, Volltext: https://aapm.onlinelibrary.wiley.com/doi/abs/10.1002/mp.13579
Get full text
Author Notes:Philipp Freislederer, Asmus von Münchow, Florian Kamp, Christian Heinz, Sabine Gerum, Stefanie Corradini, Matthias Söhn, Michael Reiner, Falk Roeder, Ralf Floca, Markus Alber, Claus Belka, Katia Parodi

MARC

LEADER 00000caa a2200000 c 4500
001 1694995151
003 DE-627
005 20230427070554.0
007 cr uuu---uuuuu
008 200420s2019 xx |||||o 00| ||eng c
024 7 |a 10.1002/mp.13579  |2 doi 
035 |a (DE-627)1694995151 
035 |a (DE-599)KXP1694995151 
035 |a (OCoLC)1341315812 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Freislederer, Philipp  |d 1986-  |e VerfasserIn  |0 (DE-588)1208655825  |0 (DE-627)1694992640  |4 aut 
245 1 0 |a Comparison of planned dose on different CT image sets to four-dimensional Monte Carlo dose recalculation using the patient's actual breathing trace for lung stereotactic body radiation therapy  |c Philipp Freislederer, Asmus von Münchow, Florian Kamp, Christian Heinz, Sabine Gerum, Stefanie Corradini, Matthias Söhn, Michael Reiner, Falk Roeder, Ralf Floca, Markus Alber, Claus Belka, Katia Parodi 
264 1 |c 10 May 2019 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 20.04.2020 
520 |a Purpose The need for four-dimensional (4D) treatment planning becomes indispensable when it comes to radiation therapy for moving tumors in the thoracic and abdominal regions. The primary purpose of this study is to combine the actual breathing trace during each individual treatment fraction with the Linac's log file information and Monte Carlo 4D dose calculations. We investigated this workflow on multiple computed tomography (CT) datasets in a clinical environment for stereotactic body radiation therapy (SBRT) treatment planning. Methods We have developed a workflow, which allows us to recalculate absorbed dose to a 4DCT dataset using Monte Carlo calculation methods and accumulate all 4D doses in order to compare them to the planned dose using the Linac's log file, a 4DCT dataset, and the patient's actual breathing curve for each individual fraction. For five lung patients, three-dimensional-conformal radiation therapy (3D-CRT) and volumetric modulated arc treatment (VMAT) treatment plans were generated on four different CT image datasets: a native free-breathing 3DCT, an average intensity projection (AIP) and a maximum intensity projection (MIP) CT both obtained from a 4DCT, and a 3DCT with density overrides based on the 3DCT (DO). The Monte Carlo 4D dose has been calculated on each 4DCT phase using the Linac's log file and the patient's breathing trace as a surrogate for tumor motion and dose was accumulated to the gross tumor volume (GTV) at the 50% breathing phase (end of exhale) using deformable image registration. Results and between 4D dose and planned dose differed largely for 3DCT-based planning and also for DO in three patients. Least dose differences between planned and recalculated dose have been found for AIP and MIP treatment planning which both tend to be superior to DO, but the results indicate a dependency on the breathing variability, tumor motion, and size. An interplay effect has not been observed in the small patient cohort. Conclusions We have developed a workflow which, to our best knowledge, is the first incorporation of the patient breathing trace over the course of all individual treatment fractions with the Linac's log file information and 4D Monte Carlo recalculations of the actual treated dose. Due to the small patient cohort, no clear recommendation on which CT can be used for SBRT treatment planning can be given, but the developed workflow, after adaption for clinical use, could be used to enhance a priori 4D Monte Carlo treatment planning in the future and help with the decision on which CT dataset treatment planning should be carried out. 
650 4 |a 4D dose calculation 
650 4 |a 4D treatment planning 
650 4 |a Monte Carlo 
650 4 |a respiratory motion 
700 1 |a Münchow, Asmus von  |e VerfasserIn  |0 (DE-588)128673830X  |0 (DE-627)1843279126  |4 aut 
700 1 |a Kamp, Florian  |e VerfasserIn  |4 aut 
700 1 |a Heinz, Christian  |e VerfasserIn  |4 aut 
700 1 |a Gerum, Sabine  |e VerfasserIn  |4 aut 
700 1 |a Corradini, Stefanie  |e VerfasserIn  |4 aut 
700 1 |a Söhn, Matthias  |e VerfasserIn  |4 aut 
700 1 |a Reiner, Michael  |e VerfasserIn  |4 aut 
700 1 |a Röder, Falk  |d 1973-  |e VerfasserIn  |0 (DE-588)130040371  |0 (DE-627)488065194  |0 (DE-576)297964550  |4 aut 
700 1 |a Floca, Ralf  |d 1978-  |e VerfasserIn  |0 (DE-588)140126007  |0 (DE-627)616036590  |0 (DE-576)314697284  |4 aut 
700 1 |a Alber, Markus  |e VerfasserIn  |0 (DE-588)1145057101  |0 (DE-627)1005461767  |0 (DE-576)495602507  |4 aut 
700 1 |a Belka, Claus  |e VerfasserIn  |4 aut 
700 1 |a Parodi, Katia  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Medical physics  |d Hoboken, NJ : Wiley, 1974  |g 46(2019), 7, Seite 3268-3277  |h Online-Ressource  |w (DE-627)265784867  |w (DE-600)1466421-5  |w (DE-576)074891243  |x 2473-4209  |7 nnas  |a Comparison of planned dose on different CT image sets to four-dimensional Monte Carlo dose recalculation using the patient's actual breathing trace for lung stereotactic body radiation therapy 
773 1 8 |g volume:46  |g year:2019  |g number:7  |g pages:3268-3277  |g extent:10  |a Comparison of planned dose on different CT image sets to four-dimensional Monte Carlo dose recalculation using the patient's actual breathing trace for lung stereotactic body radiation therapy 
856 4 0 |u https://doi.org/10.1002/mp.13579  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://aapm.onlinelibrary.wiley.com/doi/abs/10.1002/mp.13579  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200420 
993 |a Article 
994 |a 2019 
998 |g 1145057101  |a Alber, Markus  |m 1145057101:Alber, Markus  |d 910000  |d 911400  |e 910000PA1145057101  |e 911400PA1145057101  |k 0/910000/  |k 1/910000/911400/  |p 11 
998 |g 140126007  |a Floca, Ralf  |m 140126007:Floca, Ralf  |d 910000  |d 911400  |e 910000PF140126007  |e 911400PF140126007  |k 0/910000/  |k 1/910000/911400/  |p 10 
998 |g 130040371  |a Röder, Falk  |m 130040371:Röder, Falk  |d 910000  |d 911400  |e 910000PR130040371  |e 911400PR130040371  |k 0/910000/  |k 1/910000/911400/  |p 9 
999 |a KXP-PPN1694995151  |e 3627384369 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1694995151"],"doi":["10.1002/mp.13579"]},"recId":"1694995151","type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedDisp":"10 May 2019","dateIssuedKey":"2019"}],"name":{"displayForm":["Philipp Freislederer, Asmus von Münchow, Florian Kamp, Christian Heinz, Sabine Gerum, Stefanie Corradini, Matthias Söhn, Michael Reiner, Falk Roeder, Ralf Floca, Markus Alber, Claus Belka, Katia Parodi"]},"note":["Gesehen am 20.04.2020"],"language":["eng"],"person":[{"given":"Philipp","role":"aut","family":"Freislederer","display":"Freislederer, Philipp"},{"role":"aut","family":"Münchow","display":"Münchow, Asmus von","given":"Asmus von"},{"family":"Kamp","role":"aut","display":"Kamp, Florian","given":"Florian"},{"given":"Christian","display":"Heinz, Christian","family":"Heinz","role":"aut"},{"family":"Gerum","role":"aut","display":"Gerum, Sabine","given":"Sabine"},{"display":"Corradini, Stefanie","family":"Corradini","role":"aut","given":"Stefanie"},{"given":"Matthias","role":"aut","family":"Söhn","display":"Söhn, Matthias"},{"family":"Reiner","role":"aut","display":"Reiner, Michael","given":"Michael"},{"given":"Falk","role":"aut","family":"Röder","display":"Röder, Falk"},{"family":"Floca","role":"aut","display":"Floca, Ralf","given":"Ralf"},{"given":"Markus","display":"Alber, Markus","role":"aut","family":"Alber"},{"given":"Claus","display":"Belka, Claus","family":"Belka","role":"aut"},{"given":"Katia","family":"Parodi","role":"aut","display":"Parodi, Katia"}],"relHost":[{"title":[{"title":"Medical physics","title_sort":"Medical physics"}],"note":["Gesehen am 01.08.2025"],"titleAlt":[{"title":"Medical physics online"}],"pubHistory":["1.1974 -"],"id":{"zdb":["1466421-5"],"eki":["265784867"],"issn":["2473-4209","1522-8541"]},"disp":"Comparison of planned dose on different CT image sets to four-dimensional Monte Carlo dose recalculation using the patient's actual breathing trace for lung stereotactic body radiation therapyMedical physics","origin":[{"publisherPlace":"Hoboken, NJ ; College Park, Md. ; New York, NY","dateIssuedKey":"1974","dateIssuedDisp":"1974-","publisher":"Wiley ; AAPM ; [Verlag nicht ermittelbar]"}],"physDesc":[{"extent":"Online-Ressource"}],"part":{"extent":"10","issue":"7","year":"2019","pages":"3268-3277","volume":"46","text":"46(2019), 7, Seite 3268-3277"},"language":["eng"],"recId":"265784867","type":{"media":"Online-Ressource","bibl":"periodical"},"name":{"displayForm":["American Association of Physicists in Medicine ; American Institute of Physics"]}}],"physDesc":[{"extent":"10 S."}],"title":[{"title":"Comparison of planned dose on different CT image sets to four-dimensional Monte Carlo dose recalculation using the patient's actual breathing trace for lung stereotactic body radiation therapy","title_sort":"Comparison of planned dose on different CT image sets to four-dimensional Monte Carlo dose recalculation using the patient's actual breathing trace for lung stereotactic body radiation therapy"}]} 
SRT |a FREISLEDERCOMPARISON1020