Direct detection of Pu-242 with a metallic magnetic calorimeter gamma-ray detector

Cryogenic high-resolution $$\gamma $$γ-ray detectors can improve the accuracy of non-destructive assay (NDA) of nuclear materials in cases where conventional high-purity germanium detectors are limited by line overlap or by the Compton background. We have improved the performance of gamma detectors...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bates, C. (VerfasserIn) , Pies, Christian (VerfasserIn) , Kempf, Sebastian (VerfasserIn) , Hengstler, Daniel (VerfasserIn) , Fleischmann, Andreas (VerfasserIn) , Gastaldo, Loredana (VerfasserIn) , Enss, Christian (VerfasserIn) , Friedrich, S. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2016
In: Journal of low temperature physics
Year: 2015, Jahrgang: 184, Heft: 1, Pages: 351-355
ISSN:1573-7357
DOI:10.1007/s10909-015-1348-0
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s10909-015-1348-0
Volltext
Verfasserangaben:C. Bates, C. Pies, S. Kempf, D. Hengstler, A. Fleischmann, L. Gastaldo, C. Enss, S. Friedrich

MARC

LEADER 00000caa a2200000 c 4500
001 1695777980
003 DE-627
005 20220818051546.0
007 cr uuu---uuuuu
008 200423r20162015xx |||||o 00| ||eng c
024 7 |a 10.1007/s10909-015-1348-0  |2 doi 
035 |a (DE-627)1695777980 
035 |a (DE-599)KXP1695777980 
035 |a (OCoLC)1341316124 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Bates, C.  |e VerfasserIn  |0 (DE-588)1208220411  |0 (DE-627)1694430839  |4 aut 
245 1 0 |a Direct detection of Pu-242 with a metallic magnetic calorimeter gamma-ray detector  |c C. Bates, C. Pies, S. Kempf, D. Hengstler, A. Fleischmann, L. Gastaldo, C. Enss, S. Friedrich 
264 1 |c 2016 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published: 27 October 2015 
500 |a Gesehen am 23.04.2020 
520 |a Cryogenic high-resolution $$\gamma $$γ-ray detectors can improve the accuracy of non-destructive assay (NDA) of nuclear materials in cases where conventional high-purity germanium detectors are limited by line overlap or by the Compton background. We have improved the performance of gamma detectors based on metallic magnetic calorimeters (MMCs) by separating the 0.5 $$\times $$×2 $$\times $$×0.25 mm$$^{3}$$3Au absorber from the Au:Er sensor with sixteen 30-$$\upmu $$μm-diameter Au posts. This ensures that the entire $$\gamma $$γ-ray energy thermalizes in the absorber before heating the Au:Er sensor, and improves the energy resolution at 35 mK to as low as 90 eV FWHM at 60 keV. This energy resolution enables the direct detection of $$\gamma $$γ-rays from Pu-242, an isotope that cannot be measured by traditional NDA and whose concentration is therefore inferred through correlations with other Pu isotopes. The Pu-242 concentration of 11.11 $$\pm $$±0.42 % measured by NDA with MMCs agrees with mass spectrometry results and exceeds the accuracy of correlation measurements. 
534 |c 2015 
700 1 |a Pies, Christian  |e VerfasserIn  |0 (DE-588)1020440465  |0 (DE-627)691221464  |0 (DE-576)360448771  |4 aut 
700 1 |a Kempf, Sebastian  |d 1983-  |e VerfasserIn  |0 (DE-588)1020440449  |0 (DE-627)69122143X  |0 (DE-576)360448690  |4 aut 
700 1 |a Hengstler, Daniel  |e VerfasserIn  |0 (DE-588)1020440694  |0 (DE-627)691221553  |0 (DE-576)360449328  |4 aut 
700 1 |a Fleischmann, Andreas  |e VerfasserIn  |0 (DE-588)1020467568  |0 (DE-627)691226873  |0 (DE-576)360449409  |4 aut 
700 1 |a Gastaldo, Loredana  |e VerfasserIn  |0 (DE-588)1020440317  |0 (DE-627)691221340  |0 (DE-576)360449603  |4 aut 
700 1 |a Enss, Christian  |d 1960-  |e VerfasserIn  |0 (DE-588)1020467878  |0 (DE-627)691227020  |0 (DE-576)360449530  |4 aut 
700 1 |a Friedrich, S.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Journal of low temperature physics  |d Dordrecht : Springer Science + Business Media B.V., 1969  |g 184(2016), 1, Seite 351-355  |h Online-Ressource  |w (DE-627)320575411  |w (DE-600)2016984-X  |w (DE-576)094505616  |x 1573-7357  |7 nnas  |a Direct detection of Pu-242 with a metallic magnetic calorimeter gamma-ray detector 
773 1 8 |g volume:184  |g year:2016  |g number:1  |g pages:351-355  |g extent:5  |a Direct detection of Pu-242 with a metallic magnetic calorimeter gamma-ray detector 
856 4 0 |u https://doi.org/10.1007/s10909-015-1348-0  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200423 
993 |a Article 
994 |a 2016 
998 |g 1020467878  |a Enss, Christian  |m 1020467878:Enss, Christian  |d 130000  |d 130700  |e 130000PE1020467878  |e 130700PE1020467878  |k 0/130000/  |k 1/130000/130700/  |p 7 
998 |g 1020440317  |a Gastaldo, Loredana  |m 1020440317:Gastaldo, Loredana  |d 130000  |d 130700  |e 130000PG1020440317  |e 130700PG1020440317  |k 0/130000/  |k 1/130000/130700/  |p 6 
998 |g 1020467568  |a Fleischmann, Andreas  |m 1020467568:Fleischmann, Andreas  |d 130000  |d 130700  |e 130000PF1020467568  |e 130700PF1020467568  |k 0/130000/  |k 1/130000/130700/  |p 5 
998 |g 1020440694  |a Hengstler, Daniel  |m 1020440694:Hengstler, Daniel  |d 130000  |d 130700  |e 130000PH1020440694  |e 130700PH1020440694  |k 0/130000/  |k 1/130000/130700/  |p 4 
998 |g 1020440449  |a Kempf, Sebastian  |m 1020440449:Kempf, Sebastian  |d 130000  |d 130700  |e 130000PK1020440449  |e 130700PK1020440449  |k 0/130000/  |k 1/130000/130700/  |p 3 
998 |g 1020440465  |a Pies, Christian  |m 1020440465:Pies, Christian  |d 910000  |d 950000  |d 950950  |e 910000PP1020440465  |e 950000PP1020440465  |e 950950PP1020440465  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950950/  |p 2 
999 |a KXP-PPN1695777980  |e 3631027451 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1695777980","language":["eng"],"relHost":[{"part":{"text":"184(2016), 1, Seite 351-355","year":"2016","pages":"351-355","volume":"184","extent":"5","issue":"1"},"id":{"zdb":["2016984-X"],"eki":["320575411"],"issn":["1573-7357"]},"pubHistory":["1.1969 -"],"origin":[{"dateIssuedDisp":"1969-","publisher":"Springer Science + Business Media B.V. ; Plenum Press ; Kluwer Academic Publishers","dateIssuedKey":"1969","publisherPlace":"Dordrecht ; New York, NY [u.a.] ; Dordrecht"}],"disp":"Direct detection of Pu-242 with a metallic magnetic calorimeter gamma-ray detectorJournal of low temperature physics","title":[{"title":"Journal of low temperature physics","title_sort":"Journal of low temperature physics"}],"note":["Gesehen am 21.10.2020"],"recId":"320575411","language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"physDesc":[{"extent":"Online-Ressource"}]}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"name":{"displayForm":["C. Bates, C. Pies, S. Kempf, D. Hengstler, A. Fleischmann, L. Gastaldo, C. Enss, S. Friedrich"]},"physDesc":[{"extent":"5 S."}],"id":{"eki":["1695777980"],"doi":["10.1007/s10909-015-1348-0"]},"origin":[{"dateIssuedKey":"2016","dateIssuedDisp":"2016"}],"title":[{"title":"Direct detection of Pu-242 with a metallic magnetic calorimeter gamma-ray detector","title_sort":"Direct detection of Pu-242 with a metallic magnetic calorimeter gamma-ray detector"}],"person":[{"display":"Bates, C.","family":"Bates","given":"C.","role":"aut"},{"display":"Pies, Christian","given":"Christian","role":"aut","family":"Pies"},{"role":"aut","given":"Sebastian","family":"Kempf","display":"Kempf, Sebastian"},{"given":"Daniel","role":"aut","family":"Hengstler","display":"Hengstler, Daniel"},{"display":"Fleischmann, Andreas","family":"Fleischmann","given":"Andreas","role":"aut"},{"display":"Gastaldo, Loredana","given":"Loredana","role":"aut","family":"Gastaldo"},{"display":"Enss, Christian","family":"Enss","given":"Christian","role":"aut"},{"family":"Friedrich","given":"S.","role":"aut","display":"Friedrich, S."}],"note":["Published: 27 October 2015","Gesehen am 23.04.2020"]} 
SRT |a BATESCPIESDIRECTDETE2016