Helium CT: Monte Carlo simulation results for an ideal source and detector with comparison to proton CT
Purpose - To evaluate the accuracy of relative stopping power and spatial resolution of images reconstructed with simulated helium CT (HeCT) in comparison to proton CT (pCT). - - Methods - A Monte Carlo (...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
20 May 2018
|
| In: |
Medical physics
Year: 2018, Volume: 45, Issue: 7, Pages: 3264-3274 |
| ISSN: | 2473-4209 |
| DOI: | 10.1002/mp.12942 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1002/mp.12942 Verlag, lizenzpflichtig, Volltext: https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.12942 |
| Author Notes: | Pierluigi Piersimoni, Bruce A. Faddegon, José Ramos Méndez, Reinhard W. Schulte, Lennart Volz and Joao Seco |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1695779274 | ||
| 003 | DE-627 | ||
| 005 | 20230426080153.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200423s2018 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1002/mp.12942 |2 doi | |
| 035 | |a (DE-627)1695779274 | ||
| 035 | |a (DE-599)KXP1695779274 | ||
| 035 | |a (OCoLC)1341316193 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 29 |2 sdnb | ||
| 100 | 1 | |a Piersimoni, Pierluigi |e VerfasserIn |0 (DE-588)1208844288 |0 (DE-627)1695779150 |4 aut | |
| 245 | 1 | 0 | |a Helium CT |b Monte Carlo simulation results for an ideal source and detector with comparison to proton CT |c Pierluigi Piersimoni, Bruce A. Faddegon, José Ramos Méndez, Reinhard W. Schulte, Lennart Volz and Joao Seco |
| 264 | 1 | |c 20 May 2018 | |
| 300 | |a 11 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 23.04.2020 | ||
| 520 | |a Purpose - To evaluate the accuracy of relative stopping power and spatial resolution of images reconstructed with simulated helium CT (HeCT) in comparison to proton CT (pCT). - - Methods - A Monte Carlo (... | ||
| 700 | 1 | |a Volz, Lennart |d 1992- |e VerfasserIn |0 (DE-588)1164508121 |0 (DE-627)1028942141 |0 (DE-576)510057004 |4 aut | |
| 700 | 1 | |a Seco, Joao |e VerfasserIn |0 (DE-588)1120955866 |0 (DE-627)874146615 |0 (DE-576)480627010 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Medical physics |d Hoboken, NJ : Wiley, 1974 |g 45(2018), 7, Seite 3264-3274 |h Online-Ressource |w (DE-627)265784867 |w (DE-600)1466421-5 |w (DE-576)074891243 |x 2473-4209 |7 nnas |a Helium CT Monte Carlo simulation results for an ideal source and detector with comparison to proton CT |
| 773 | 1 | 8 | |g volume:45 |g year:2018 |g number:7 |g pages:3264-3274 |g extent:11 |a Helium CT Monte Carlo simulation results for an ideal source and detector with comparison to proton CT |
| 856 | 4 | 0 | |u https://doi.org/10.1002/mp.12942 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.12942 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200423 | ||
| 993 | |a Article | ||
| 994 | |a 2018 | ||
| 998 | |g 1120955866 |a Seco, Joao |m 1120955866:Seco, Joao |d 130000 |e 130000PS1120955866 |k 0/130000/ |p 6 |y j | ||
| 998 | |g 1164508121 |a Volz, Lennart |m 1164508121:Volz, Lennart |d 130000 |e 130000PV1164508121 |k 0/130000/ |p 5 | ||
| 999 | |a KXP-PPN1695779274 |e 3631045018 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"pubHistory":["1.1974 -"],"recId":"265784867","name":{"displayForm":["American Association of Physicists in Medicine ; American Institute of Physics"]},"physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["2473-4209","1522-8541"],"eki":["265784867"],"zdb":["1466421-5"]},"disp":"Helium CT Monte Carlo simulation results for an ideal source and detector with comparison to proton CTMedical physics","language":["eng"],"note":["Gesehen am 01.08.2025"],"origin":[{"publisherPlace":"Hoboken, NJ ; College Park, Md. ; New York, NY","dateIssuedDisp":"1974-","dateIssuedKey":"1974","publisher":"Wiley ; AAPM ; [Verlag nicht ermittelbar]"}],"titleAlt":[{"title":"Medical physics online"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"title":[{"title":"Medical physics","title_sort":"Medical physics"}],"part":{"year":"2018","pages":"3264-3274","text":"45(2018), 7, Seite 3264-3274","extent":"11","volume":"45","issue":"7"}}],"id":{"eki":["1695779274"],"doi":["10.1002/mp.12942"]},"name":{"displayForm":["Pierluigi Piersimoni, Bruce A. Faddegon, José Ramos Méndez, Reinhard W. Schulte, Lennart Volz and Joao Seco"]},"physDesc":[{"extent":"11 S."}],"recId":"1695779274","origin":[{"dateIssuedDisp":"20 May 2018","dateIssuedKey":"2018"}],"note":["Gesehen am 23.04.2020"],"title":[{"title":"Helium CT","subtitle":"Monte Carlo simulation results for an ideal source and detector with comparison to proton CT","title_sort":"Helium CT"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"person":[{"display":"Piersimoni, Pierluigi","family":"Piersimoni","role":"aut","given":"Pierluigi"},{"role":"aut","given":"Lennart","display":"Volz, Lennart","family":"Volz"},{"role":"aut","given":"Joao","display":"Seco, Joao","family":"Seco"}]} | ||
| SRT | |a PIERSIMONIHELIUMCT2020 | ||