Adaptive model-based myoelectric control for a soft wearable arm exosuit: a new generation of wearable robot control
Despite advances in mechatronic design, the widespread adoption of wearable robots for supporting human mobility has been hampered by 1) ergonomic limitations in rigid exoskeletal structures and 2) the lack of human-machine interfaces (HMIs) capable of sensing musculoskeletal states and translating...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
20 January 2020
|
| In: |
IEEE robotics & automation magazine
Year: 2020, Volume: 27, Issue: 1, Pages: 43-53 |
| DOI: | 10.1109/MRA.2019.2955669 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1109/MRA.2019.2955669 Verlag: https://ieeexplore.ieee.org/abstract/document/8963852 |
| Author Notes: | Nicola Lotti, Michele Xiloyannis, Guillaume Durandau, Elisa Galofaro, Vittorio Sanguineti, Lorenzo Masia, Massimo Sartori |
MARC
| LEADER | 00000caa a22000002c 4500 | ||
|---|---|---|---|
| 001 | 1696822521 | ||
| 003 | DE-627 | ||
| 005 | 20220818061226.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200429s2020 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1109/MRA.2019.2955669 |2 doi | |
| 035 | |a (DE-627)1696822521 | ||
| 035 | |a (DE-599)KXP1696822521 | ||
| 035 | |a (OCoLC)1341317364 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 28 |2 sdnb | ||
| 100 | 1 | |a Lotti, Nicola |e VerfasserIn |0 (DE-588)120921539X |0 (DE-627)1696828430 |4 aut | |
| 245 | 1 | 0 | |a Adaptive model-based myoelectric control for a soft wearable arm exosuit |b a new generation of wearable robot control |c Nicola Lotti, Michele Xiloyannis, Guillaume Durandau, Elisa Galofaro, Vittorio Sanguineti, Lorenzo Masia, Massimo Sartori |
| 264 | 1 | |c 20 January 2020 | |
| 300 | |a 11 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 29.04.2020 | ||
| 520 | |a Despite advances in mechatronic design, the widespread adoption of wearable robots for supporting human mobility has been hampered by 1) ergonomic limitations in rigid exoskeletal structures and 2) the lack of human-machine interfaces (HMIs) capable of sensing musculoskeletal states and translating them into robot-control commands. We have developed a framework that combines, for the first time, a model-based HMI with a soft wearable arm exosuit that has the potential to address key limitations in current HMIs and wearable robots. The proposed framework was tested on six healthy subjects who performed elbow rotations across different joint velocities and lifting weights. The results showed that the model-controlled exosuit operated synchronously with biological muscle contraction. Remarkably, the exosuit dynamically modulated mechanical assistance across all investigated loads, thereby displaying adaptive behavior. | ||
| 650 | 4 | |a adaptive control | |
| 650 | 4 | |a adaptive model-based myoelectric control | |
| 650 | 4 | |a Elbow | |
| 650 | 4 | |a electromyography | |
| 650 | 4 | |a Electromyography | |
| 650 | 4 | |a human mobility | |
| 650 | 4 | |a human-machine interfaces | |
| 650 | 4 | |a human-robot interaction | |
| 650 | 4 | |a mechatronic design | |
| 650 | 4 | |a mechatronics | |
| 650 | 4 | |a Medical robotics | |
| 650 | 4 | |a model-based HMI | |
| 650 | 4 | |a model-controlled exosuit | |
| 650 | 4 | |a motion control | |
| 650 | 4 | |a Muscles | |
| 650 | 4 | |a rigid exoskeletal structures | |
| 650 | 4 | |a soft wearable arm exosuit | |
| 650 | 4 | |a Torque | |
| 650 | 4 | |a wearable robot control | |
| 650 | 4 | |a wearable robots | |
| 650 | 4 | |a Wearable robots | |
| 700 | 1 | |a Masia, Lorenzo |e VerfasserIn |0 (DE-588)1186660864 |0 (DE-627)1665956569 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |a Institute of Electrical and Electronics Engineers |t IEEE robotics & automation magazine |d New York, NY : IEEE, 1994 |g 27(2020), 1, Seite 43-53 |h Online-Ressource |w (DE-627)324489773 |w (DE-600)2027730-1 |w (DE-576)09408596X |7 nnas |
| 773 | 1 | 8 | |g volume:27 |g year:2020 |g number:1 |g pages:43-53 |g extent:11 |a Adaptive model-based myoelectric control for a soft wearable arm exosuit a new generation of wearable robot control |
| 856 | 4 | 0 | |u https://doi.org/10.1109/MRA.2019.2955669 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://ieeexplore.ieee.org/abstract/document/8963852 |x Verlag |
| 951 | |a AR | ||
| 992 | |a 20200429 | ||
| 993 | |a Article | ||
| 994 | |a 2020 | ||
| 998 | |g 1186660864 |a Masia, Lorenzo |m 1186660864:Masia, Lorenzo |d 700000 |d 720000 |e 700000PM1186660864 |e 720000PM1186660864 |k 0/700000/ |k 1/700000/720000/ |p 6 | ||
| 998 | |g 120921539X |a Lotti, Nicola |m 120921539X:Lotti, Nicola |d 700000 |d 720000 |e 700000PL120921539X |e 720000PL120921539X |k 0/700000/ |k 1/700000/720000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1696822521 |e 3642472621 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"note":["Gesehen am 29.04.2020"],"name":{"displayForm":["Nicola Lotti, Michele Xiloyannis, Guillaume Durandau, Elisa Galofaro, Vittorio Sanguineti, Lorenzo Masia, Massimo Sartori"]},"person":[{"display":"Lotti, Nicola","roleDisplay":"VerfasserIn","role":"aut","given":"Nicola","family":"Lotti"},{"family":"Masia","display":"Masia, Lorenzo","role":"aut","roleDisplay":"VerfasserIn","given":"Lorenzo"}],"id":{"eki":["1696822521"],"doi":["10.1109/MRA.2019.2955669"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"recId":"1696822521","relHost":[{"pubHistory":["1.1994 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"title":[{"title_sort":"IEEE robotics & automation magazine","title":"IEEE robotics & automation magazine"}],"recId":"324489773","disp":"Institute of Electrical and Electronics EngineersIEEE robotics & automation magazine","origin":[{"dateIssuedDisp":"1994-","dateIssuedKey":"1994","publisher":"IEEE","publisherPlace":"New York, NY"}],"physDesc":[{"extent":"Online-Ressource"}],"name":{"displayForm":["publ. quarterly by the IEEE Robotics & Automation Society"]},"note":["Gesehen am 05.12.06"],"part":{"extent":"11","year":"2020","issue":"1","volume":"27","text":"27(2020), 1, Seite 43-53","pages":"43-53"},"id":{"zdb":["2027730-1"],"eki":["324489773"]},"corporate":[{"display":"Institute of Electrical and Electronics Engineers","roleDisplay":"VerfasserIn","role":"aut"},{"display":"IEEE Robotics and Automation Society","roleDisplay":"Herausgebendes Organ","role":"isb"}]}],"title":[{"title_sort":"Adaptive model-based myoelectric control for a soft wearable arm exosuit","title":"Adaptive model-based myoelectric control for a soft wearable arm exosuit","subtitle":"a new generation of wearable robot control"}],"physDesc":[{"extent":"11 S."}],"origin":[{"dateIssuedDisp":"20 January 2020","dateIssuedKey":"2020"}]} | ||
| SRT | |a LOTTINICOLADAPTIVEMO2020 | ||