Adaptive model-based myoelectric control for a soft wearable arm exosuit: a new generation of wearable robot control

Despite advances in mechatronic design, the widespread adoption of wearable robots for supporting human mobility has been hampered by 1) ergonomic limitations in rigid exoskeletal structures and 2) the lack of human-machine interfaces (HMIs) capable of sensing musculoskeletal states and translating...

Full description

Saved in:
Bibliographic Details
Main Authors: Lotti, Nicola (Author) , Masia, Lorenzo (Author)
Format: Article (Journal)
Language:English
Published: 20 January 2020
In: IEEE robotics & automation magazine
Year: 2020, Volume: 27, Issue: 1, Pages: 43-53
DOI:10.1109/MRA.2019.2955669
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1109/MRA.2019.2955669
Verlag: https://ieeexplore.ieee.org/abstract/document/8963852
Get full text
Author Notes:Nicola Lotti, Michele Xiloyannis, Guillaume Durandau, Elisa Galofaro, Vittorio Sanguineti, Lorenzo Masia, Massimo Sartori

MARC

LEADER 00000caa a22000002c 4500
001 1696822521
003 DE-627
005 20220818061226.0
007 cr uuu---uuuuu
008 200429s2020 xx |||||o 00| ||eng c
024 7 |a 10.1109/MRA.2019.2955669  |2 doi 
035 |a (DE-627)1696822521 
035 |a (DE-599)KXP1696822521 
035 |a (OCoLC)1341317364 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 28  |2 sdnb 
100 1 |a Lotti, Nicola  |e VerfasserIn  |0 (DE-588)120921539X  |0 (DE-627)1696828430  |4 aut 
245 1 0 |a Adaptive model-based myoelectric control for a soft wearable arm exosuit  |b a new generation of wearable robot control  |c Nicola Lotti, Michele Xiloyannis, Guillaume Durandau, Elisa Galofaro, Vittorio Sanguineti, Lorenzo Masia, Massimo Sartori 
264 1 |c 20 January 2020 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 29.04.2020 
520 |a Despite advances in mechatronic design, the widespread adoption of wearable robots for supporting human mobility has been hampered by 1) ergonomic limitations in rigid exoskeletal structures and 2) the lack of human-machine interfaces (HMIs) capable of sensing musculoskeletal states and translating them into robot-control commands. We have developed a framework that combines, for the first time, a model-based HMI with a soft wearable arm exosuit that has the potential to address key limitations in current HMIs and wearable robots. The proposed framework was tested on six healthy subjects who performed elbow rotations across different joint velocities and lifting weights. The results showed that the model-controlled exosuit operated synchronously with biological muscle contraction. Remarkably, the exosuit dynamically modulated mechanical assistance across all investigated loads, thereby displaying adaptive behavior. 
650 4 |a adaptive control 
650 4 |a adaptive model-based myoelectric control 
650 4 |a Elbow 
650 4 |a electromyography 
650 4 |a Electromyography 
650 4 |a human mobility 
650 4 |a human-machine interfaces 
650 4 |a human-robot interaction 
650 4 |a mechatronic design 
650 4 |a mechatronics 
650 4 |a Medical robotics 
650 4 |a model-based HMI 
650 4 |a model-controlled exosuit 
650 4 |a motion control 
650 4 |a Muscles 
650 4 |a rigid exoskeletal structures 
650 4 |a soft wearable arm exosuit 
650 4 |a Torque 
650 4 |a wearable robot control 
650 4 |a wearable robots 
650 4 |a Wearable robots 
700 1 |a Masia, Lorenzo  |e VerfasserIn  |0 (DE-588)1186660864  |0 (DE-627)1665956569  |4 aut 
773 0 8 |i Enthalten in  |a Institute of Electrical and Electronics Engineers  |t IEEE robotics & automation magazine  |d New York, NY : IEEE, 1994  |g 27(2020), 1, Seite 43-53  |h Online-Ressource  |w (DE-627)324489773  |w (DE-600)2027730-1  |w (DE-576)09408596X  |7 nnas 
773 1 8 |g volume:27  |g year:2020  |g number:1  |g pages:43-53  |g extent:11  |a Adaptive model-based myoelectric control for a soft wearable arm exosuit a new generation of wearable robot control 
856 4 0 |u https://doi.org/10.1109/MRA.2019.2955669  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://ieeexplore.ieee.org/abstract/document/8963852  |x Verlag 
951 |a AR 
992 |a 20200429 
993 |a Article 
994 |a 2020 
998 |g 1186660864  |a Masia, Lorenzo  |m 1186660864:Masia, Lorenzo  |d 700000  |d 720000  |e 700000PM1186660864  |e 720000PM1186660864  |k 0/700000/  |k 1/700000/720000/  |p 6 
998 |g 120921539X  |a Lotti, Nicola  |m 120921539X:Lotti, Nicola  |d 700000  |d 720000  |e 700000PL120921539X  |e 720000PL120921539X  |k 0/700000/  |k 1/700000/720000/  |p 1  |x j 
999 |a KXP-PPN1696822521  |e 3642472621 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 29.04.2020"],"name":{"displayForm":["Nicola Lotti, Michele Xiloyannis, Guillaume Durandau, Elisa Galofaro, Vittorio Sanguineti, Lorenzo Masia, Massimo Sartori"]},"person":[{"display":"Lotti, Nicola","roleDisplay":"VerfasserIn","role":"aut","given":"Nicola","family":"Lotti"},{"family":"Masia","display":"Masia, Lorenzo","role":"aut","roleDisplay":"VerfasserIn","given":"Lorenzo"}],"id":{"eki":["1696822521"],"doi":["10.1109/MRA.2019.2955669"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"recId":"1696822521","relHost":[{"pubHistory":["1.1994 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"title":[{"title_sort":"IEEE robotics & automation magazine","title":"IEEE robotics & automation magazine"}],"recId":"324489773","disp":"Institute of Electrical and Electronics EngineersIEEE robotics & automation magazine","origin":[{"dateIssuedDisp":"1994-","dateIssuedKey":"1994","publisher":"IEEE","publisherPlace":"New York, NY"}],"physDesc":[{"extent":"Online-Ressource"}],"name":{"displayForm":["publ. quarterly by the IEEE Robotics & Automation Society"]},"note":["Gesehen am 05.12.06"],"part":{"extent":"11","year":"2020","issue":"1","volume":"27","text":"27(2020), 1, Seite 43-53","pages":"43-53"},"id":{"zdb":["2027730-1"],"eki":["324489773"]},"corporate":[{"display":"Institute of Electrical and Electronics Engineers","roleDisplay":"VerfasserIn","role":"aut"},{"display":"IEEE Robotics and Automation Society","roleDisplay":"Herausgebendes Organ","role":"isb"}]}],"title":[{"title_sort":"Adaptive model-based myoelectric control for a soft wearable arm exosuit","title":"Adaptive model-based myoelectric control for a soft wearable arm exosuit","subtitle":"a new generation of wearable robot control"}],"physDesc":[{"extent":"11 S."}],"origin":[{"dateIssuedDisp":"20 January 2020","dateIssuedKey":"2020"}]} 
SRT |a LOTTINICOLADAPTIVEMO2020