Objectives To compare ultimate fracture load (Fu), load at first damage (F1d), and fracture pattern for posterior fixed dental prostheses (FDPs) manufactured from translucent, yttria-stabilized zirconia polycrystal. Methods Premolar-size FDPs in 4 test groups (n = 16/group) were constructed as venee...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bömicke, Wolfgang (VerfasserIn) , Rues, Stefan (VerfasserIn) , Hlavacek, Verena Anna (VerfasserIn) , Rammelsberg, Peter (VerfasserIn) , Schmitter, Marc (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 26 August 2016
In: Journal of esthetic and restorative dentistry
Year: 2016, Jahrgang: 28, Heft: 6, Pages: 367-381
ISSN:1708-8240
DOI:10.1111/jerd.12242
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1111/jerd.12242
Verlag, lizenzpflichtig, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/jerd.12242
Volltext
Verfasserangaben:Wolfgang Bömicke, Stefan Rues, Verena Hlavacek, Peter Rammelsberg, Marc Schmitter

MARC

LEADER 00000caa a2200000 c 4500
001 1698238630
003 DE-627
005 20220818084625.0
007 cr uuu---uuuuu
008 200514s2016 xx |||||o 00| ||eng c
024 7 |a 10.1111/jerd.12242  |2 doi 
035 |a (DE-627)1698238630 
035 |a (DE-599)KXP1698238630 
035 |a (OCoLC)1341323920 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Bömicke, Wolfgang  |d 1981-  |e VerfasserIn  |0 (DE-588)1015022146  |0 (DE-627)668338792  |0 (DE-576)349947651  |4 aut 
245 1 0 |a Fracture behavior of minimally invasive, posterior, and fixed dental prostheses manufactured from monolithic zirconia  |c Wolfgang Bömicke, Stefan Rues, Verena Hlavacek, Peter Rammelsberg, Marc Schmitter 
264 1 |c 26 August 2016 
300 |a 15 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 14.05.2020 
520 |a Objectives To compare ultimate fracture load (Fu), load at first damage (F1d), and fracture pattern for posterior fixed dental prostheses (FDPs) manufactured from translucent, yttria-stabilized zirconia polycrystal. Methods Premolar-size FDPs in 4 test groups (n = 16/group) were constructed as veneered complete crown-retained (group 1), monolithic complete crown-retained (group 2), monolithic partial veneer crown-retained (group 3), or monolithic resin-bonded (group 4) prostheses with minimum zirconia wall thickness (0.5 mm). Adhesively cemented to metal abutments, half of the prostheses were artificially aged by use of 10,000 thermocycles (6.5°C/60°C) and 1,200,000 chewing cycles (F = 108 N), before fracture loading. Statistics included two-way non-parametric ANOVA and Dunn-Bonferroni post-hoc tests (α = 0.05). Results None of the restorations failed during artificial aging. Fu was affected by test group (p < 0.001); F1d was also affected by the factor combination of test group and aging (p = 0.001 for test group; p = 0.049 for test group*aging). Mean Fu for all groups exceeded 1000 N; it was comparable for group 1 and group 2 and statistically significantly higher for group 2 and group 3 than for group 4 (p < 0.01). Fracture usually occurred through the retainer wall. F1d = 200 N was determined for individual samples in group 1 (chipping) and group 3 (local debonding). Conclusions Fu of all the restorations was adequate for clinical use. Complications might, however, be expected at forces below 500 N for veneered prostheses (chipping) as well as for monolithic partial veneer crown-retained prostheses (local debonding). Clinical Significance With regard to fracture behavior, all-ceramic complete crown-retained fixed dental prostheses (FDP) manufactured from monolithic zirconia, with a retainer wall thickness of 0.5 mm, might be suitable for use as a conservative alternative to their veneered counterparts in the rehabilitation of posterior tooth loss. Monolithic zirconia resin-bonded FDP might, moreover, be a viable alternative to resin-bonded FDPs with metal adhesive retainers in posterior arches, with improved esthetics and biocompatibility. The performance of both should, however, be verified in clinical trials. (J Esthet Restor Dent 28:367-381, 2016) 
700 1 |a Rues, Stefan  |e VerfasserIn  |0 (DE-588)1054444927  |0 (DE-627)792098331  |0 (DE-576)410292168  |4 aut 
700 1 |a Hlavacek, Verena Anna  |d 1988-  |e VerfasserIn  |0 (DE-588)1173989897  |0 (DE-627)1043808809  |0 (DE-576)515812897  |4 aut 
700 1 |a Rammelsberg, Peter  |d 1959-  |e VerfasserIn  |0 (DE-588)122469836  |0 (DE-627)705920836  |0 (DE-576)293285640  |4 aut 
700 1 |a Schmitter, Marc  |d 1970-  |e VerfasserIn  |0 (DE-588)12087024X  |0 (DE-627)705051471  |0 (DE-576)180188836  |4 aut 
773 0 8 |i Enthalten in  |t Journal of esthetic and restorative dentistry  |d Oxford [u.a.] : Wiley-Blackwell, 2001  |g 28(2016), 6, Seite 367-381  |h Online-Ressource  |w (DE-627)364470399  |w (DE-600)2110391-4  |w (DE-576)116331070  |x 1708-8240  |7 nnas  |a Fracture behavior of minimally invasive, posterior, and fixed dental prostheses manufactured from monolithic zirconia 
773 1 8 |g volume:28  |g year:2016  |g number:6  |g pages:367-381  |g extent:15  |a Fracture behavior of minimally invasive, posterior, and fixed dental prostheses manufactured from monolithic zirconia 
856 4 0 |u https://doi.org/10.1111/jerd.12242  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1111/jerd.12242  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200514 
993 |a Article 
994 |a 2016 
998 |g 12087024X  |a Schmitter, Marc  |m 12087024X:Schmitter, Marc  |d 910000  |d 910800  |e 910000PS12087024X  |e 910800PS12087024X  |k 0/910000/  |k 1/910000/910800/  |p 5  |y j 
998 |g 122469836  |a Rammelsberg, Peter  |m 122469836:Rammelsberg, Peter  |d 910000  |d 910800  |e 910000PR122469836  |e 910800PR122469836  |k 0/910000/  |k 1/910000/910800/  |p 4 
998 |g 1173989897  |a Hlavacek, Verena Anna  |m 1173989897:Hlavacek, Verena Anna  |p 3 
998 |g 1054444927  |a Rues, Stefan  |m 1054444927:Rues, Stefan  |d 910000  |d 910800  |e 910000PR1054444927  |e 910800PR1054444927  |k 0/910000/  |k 1/910000/910800/  |p 2 
998 |g 1015022146  |a Bömicke, Wolfgang  |m 1015022146:Bömicke, Wolfgang  |d 910000  |d 910800  |e 910000PB1015022146  |e 910800PB1015022146  |k 0/910000/  |k 1/910000/910800/  |p 1  |x j 
999 |a KXP-PPN1698238630  |e 3666836704 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 14.05.2020"],"recId":"1698238630","name":{"displayForm":["Wolfgang Bömicke, Stefan Rues, Verena Hlavacek, Peter Rammelsberg, Marc Schmitter"]},"origin":[{"dateIssuedKey":"2016","dateIssuedDisp":"26 August 2016"}],"id":{"doi":["10.1111/jerd.12242"],"eki":["1698238630"]},"physDesc":[{"extent":"15 S."}],"relHost":[{"id":{"zdb":["2110391-4"],"eki":["364470399"],"doi":["10.1111/(ISSN)1708-8240"],"issn":["1708-8240"]},"titleAlt":[{"title":"JERD"}],"note":["Gesehen am 23.02.12"],"part":{"text":"28(2016), 6, Seite 367-381","pages":"367-381","year":"2016","extent":"15","volume":"28","issue":"6"},"recId":"364470399","type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["13.2001 -"],"title":[{"title":"Journal of esthetic and restorative dentistry","title_sort":"Journal of esthetic and restorative dentistry","subtitle":"JERD"}],"language":["eng"],"disp":"Fracture behavior of minimally invasive, posterior, and fixed dental prostheses manufactured from monolithic zirconiaJournal of esthetic and restorative dentistry","origin":[{"dateIssuedDisp":"2001-","publisher":"Wiley-Blackwell ; Decker ; Blackwell","dateIssuedKey":"2001","publisherPlace":"Oxford [u.a.] ; Hamilton, Ont. ; Oxford [u.a.]"}],"physDesc":[{"extent":"Online-Ressource"}]}],"person":[{"display":"Bömicke, Wolfgang","role":"aut","roleDisplay":"VerfasserIn","given":"Wolfgang","family":"Bömicke"},{"display":"Rues, Stefan","role":"aut","roleDisplay":"VerfasserIn","given":"Stefan","family":"Rues"},{"family":"Hlavacek","role":"aut","roleDisplay":"VerfasserIn","given":"Verena Anna","display":"Hlavacek, Verena Anna"},{"given":"Peter","roleDisplay":"VerfasserIn","role":"aut","display":"Rammelsberg, Peter","family":"Rammelsberg"},{"family":"Schmitter","display":"Schmitter, Marc","role":"aut","roleDisplay":"VerfasserIn","given":"Marc"}],"language":["eng"],"title":[{"title_sort":"Fracture behavior of minimally invasive, posterior, and fixed dental prostheses manufactured from monolithic zirconia","title":"Fracture behavior of minimally invasive, posterior, and fixed dental prostheses manufactured from monolithic zirconia"}]} 
SRT |a BOEMICKEWOFRACTUREBE2620