Influence on intraocular lens power calculation of corneal radii measurement using an image-guided system
Purpose - To analyze the influence on intraocular lens (IOL) power calculation of corneal radii measured by the Verion Image-Guided System in comparison with those measured by partial coherence interferometry (PCI) (IOLMaster) and optical low-coherence reflectometry (OLCR) (Lenstar) systems...
Gespeichert in:
| Hauptverfasser: | , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
November 2016
|
| In: |
Journal of cataract and refractive surgery
Year: 2016, Jahrgang: 42, Heft: 11, Pages: 1588-1594 |
| ISSN: | 1873-4502 |
| DOI: | 10.1016/j.jcrs.2016.08.028 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jcrs.2016.08.028 Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/jcrs/Abstract/2016/11000/Influence_on_intraocular_lens_power_calculation_of.7.aspx |
| Verfasserangaben: | Bettina C. Thomas, Andreas Mueller, Gerd U. Auffarth, Mike P. Holzer |
MARC
| LEADER | 00000caa a22000002c 4500 | ||
|---|---|---|---|
| 001 | 1698872801 | ||
| 003 | DE-627 | ||
| 005 | 20240406193204.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200527s2016 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.jcrs.2016.08.028 |2 doi | |
| 035 | |a (DE-627)1698872801 | ||
| 035 | |a (DE-599)KXP1698872801 | ||
| 035 | |a (OCoLC)1341326586 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Thomas, Bettina C. |e VerfasserIn |0 (DE-588)1118879422 |0 (DE-627)872356655 |0 (DE-576)479680574 |4 aut | |
| 245 | 1 | 0 | |a Influence on intraocular lens power calculation of corneal radii measurement using an image-guided system |c Bettina C. Thomas, Andreas Mueller, Gerd U. Auffarth, Mike P. Holzer |
| 264 | 1 | |c November 2016 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 27.05.2020 | ||
| 520 | |a Purpose - To analyze the influence on intraocular lens (IOL) power calculation of corneal radii measured by the Verion Image-Guided System in comparison with those measured by partial coherence interferometry (PCI) (IOLMaster) and optical low-coherence reflectometry (OLCR) (Lenstar) systems. - Setting - International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. - Design - Prospective case series. - Methods - One eye of ophthalmologically healthy volunteers was examined with the image-guided, PCI, and OLCR systems. Corneal radii could be measured with all 3 devices; axial length (AL) and anterior chamber depth (ACD) could be measured with PCI and OLCR only. The IOL power calculations for the Acrysof SN60WF IOL using 4 formulas were compared between the image-guided system and both the PCI device and OLCR device. For IOL calculation with the image-guided system, the AL and ACD of the device used for comparison were applied. - Results - Of the 150 volunteers, 136 (mean age 39.60 years ± 17.31 [SD]) had valid measurements with all 3 devices and were included in the analysis. Compared with PCI, the image-guided system measured statistically significant larger values for corneal radii and IOL power calculations for all 4 formulas. There were no statistically significant differences between the image-guided system and the OLCR device. In both groups, the surgeon would have chosen the same IOL power in approximately 60% to 65% of cases and a ±0.5 diopter different IOL power in approximately 30% to 35% of cases when using the image-guided system. - Conclusions - The IOL power calculation using the image-guided system showed statistically significant differences compared with the PCI device but not when compared with the OLCR device. The clinical relevance of this theoretical approach remains to be evaluated. - Financial Disclosure - Drs. Auffarth and Holzer received travel grants and lecture fees from Alcon Pharma GmbH and Carl Zeiss Meditec AG. | ||
| 700 | 1 | |a Müller, Andreas |e VerfasserIn |0 (DE-588)1186948043 |0 (DE-627)1666245550 |4 aut | |
| 700 | 1 | |a Auffarth, Gerd U. |d 1964- |e VerfasserIn |0 (DE-588)123385261 |0 (DE-627)577130420 |0 (DE-576)293687277 |4 aut | |
| 700 | 1 | |a Holzer, Mike P. |d 1973- |e VerfasserIn |0 (DE-588)122217527 |0 (DE-627)705818640 |0 (DE-576)293157812 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of cataract and refractive surgery |d Hagerstown, MD : Wolters Kluwer Health, 1986 |g 42(2016), 11, Seite 1588-1594 |h Online-Ressource |w (DE-627)320594203 |w (DE-600)2019330-0 |w (DE-576)260773891 |x 1873-4502 |7 nnas |a Influence on intraocular lens power calculation of corneal radii measurement using an image-guided system |
| 773 | 1 | 8 | |g volume:42 |g year:2016 |g number:11 |g pages:1588-1594 |g extent:7 |a Influence on intraocular lens power calculation of corneal radii measurement using an image-guided system |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.jcrs.2016.08.028 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://journals.lww.com/jcrs/Abstract/2016/11000/Influence_on_intraocular_lens_power_calculation_of.7.aspx |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200527 | ||
| 993 | |a Article | ||
| 994 | |a 2016 | ||
| 998 | |g 122217527 |a Holzer, Mike P. |m 122217527:Holzer, Mike P. |d 910000 |d 910900 |e 910000PH122217527 |e 910900PH122217527 |k 0/910000/ |k 1/910000/910900/ |p 4 |y j | ||
| 998 | |g 123385261 |a Auffarth, Gerd U. |m 123385261:Auffarth, Gerd U. |d 910000 |d 910900 |e 910000PA123385261 |e 910900PA123385261 |k 0/910000/ |k 1/910000/910900/ |p 3 | ||
| 998 | |g 1186948043 |a Müller, Andreas |m 1186948043:Müller, Andreas |p 2 | ||
| 998 | |g 1118879422 |a Thomas, Bettina C. |m 1118879422:Thomas, Bettina C. |d 910000 |d 913000 |e 910000PT1118879422 |e 913000PT1118879422 |k 0/910000/ |k 1/910000/913000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1698872801 |e 3671691905 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"id":{"doi":["10.1016/j.jcrs.2016.08.028"],"eki":["1698872801"]},"language":["eng"],"person":[{"roleDisplay":"VerfasserIn","given":"Bettina C.","display":"Thomas, Bettina C.","family":"Thomas","role":"aut"},{"role":"aut","family":"Müller","display":"Müller, Andreas","given":"Andreas","roleDisplay":"VerfasserIn"},{"given":"Gerd U.","roleDisplay":"VerfasserIn","display":"Auffarth, Gerd U.","family":"Auffarth","role":"aut"},{"family":"Holzer","role":"aut","given":"Mike P.","roleDisplay":"VerfasserIn","display":"Holzer, Mike P."}],"recId":"1698872801","name":{"displayForm":["Bettina C. Thomas, Andreas Mueller, Gerd U. Auffarth, Mike P. Holzer"]},"title":[{"title_sort":"Influence on intraocular lens power calculation of corneal radii measurement using an image-guided system","title":"Influence on intraocular lens power calculation of corneal radii measurement using an image-guided system"}],"origin":[{"dateIssuedKey":"2016","dateIssuedDisp":"November 2016"}],"note":["Gesehen am 27.05.2020"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"physDesc":[{"extent":"7 S."}],"relHost":[{"recId":"320594203","titleAlt":[{"title":"Journal of cataract & refractive surgery"}],"id":{"eki":["320594203"],"issn":["1873-4502"],"zdb":["2019330-0"]},"language":["eng"],"disp":"Influence on intraocular lens power calculation of corneal radii measurement using an image-guided systemJournal of cataract and refractive surgery","title":[{"title_sort":"Journal of cataract and refractive surgery","title":"Journal of cataract and refractive surgery"}],"part":{"pages":"1588-1594","issue":"11","text":"42(2016), 11, Seite 1588-1594","extent":"7","year":"2016","volume":"42"},"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"dateIssuedKey":"2020","publisherPlace":"Hagerstown, MD ; Fairfax, Va ; Amsterdam [u.a.]","publisher":"Wolters Kluwer Health ; American Society of Cataract and Refractive Surgery ; Elsevier","dateIssuedDisp":"2020-"}],"note":["Gesehen am 02.08.24"],"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["12.1986 -"],"name":{"displayForm":["American Society of Cataract and Refractive Surgery"]}}]} | ||
| SRT | |a THOMASBETTINFLUENCEO2016 | ||