Design of an optimised preamplifier for the MRPC detector

Multi-gap Resistive Plate Chamber (MRPC) is widely used in many major international projects as an important element of the Time-of-flight (TOF) system because of its high time resolution. The typical time resolution of a MRPC system is about 60 ps, while the intrinsic time resolution of the MRPC de...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Li, Yulan (VerfasserIn) , Yue, Xiaoguang (VerfasserIn) , Zeng, M. (VerfasserIn) , Cang, J. (VerfasserIn) , Li, Z. (VerfasserIn) , Wang, Y. (VerfasserIn) , Yu, Y. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 10 February 2020
In: Journal of Instrumentation
Year: 2020, Jahrgang: 15, Heft: 2
ISSN:1748-0221
DOI:10.1088/1748-0221/15/02/P02006
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1088/1748-0221/15/02/P02006
Volltext
Verfasserangaben:Y. Li, X. Yue, M. Zeng, J. Cang, Z. Li, Y. Wang, Y. Yu

MARC

LEADER 00000caa a2200000 c 4500
001 1698901402
003 DE-627
005 20220818101309.0
007 cr uuu---uuuuu
008 200527s2020 xx |||||o 00| ||eng c
024 7 |a 10.1088/1748-0221/15/02/P02006  |2 doi 
035 |a (DE-627)1698901402 
035 |a (DE-599)KXP1698901402 
035 |a (OCoLC)1341326657 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Li, Yulan  |e VerfasserIn  |0 (DE-588)1211043053  |0 (DE-627)1698903332  |4 aut 
245 1 0 |a Design of an optimised preamplifier for the MRPC detector  |c Y. Li, X. Yue, M. Zeng, J. Cang, Z. Li, Y. Wang, Y. Yu 
264 1 |c 10 February 2020 
300 |a ? 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 27.05.2020 
520 |a Multi-gap Resistive Plate Chamber (MRPC) is widely used in many major international projects as an important element of the Time-of-flight (TOF) system because of its high time resolution. The typical time resolution of a MRPC system is about 60 ps, while the intrinsic time resolution of the MRPC detector can be smaller than 20 ps. This paper aims to improve the time resolution preformance of a 32-gap, 104 mu m-thick MRPC system by optimising the readout electronics, which consists of a current mirror (CM) and a modified transimpedance amplifier (TIA). A nominal time resolution of 11.37 ps can be achieved for a MRPC detector with a delta current signal input and a charge of around 34 fC according to a MATLAB simulation. The MRPC system using this preamplifier can achieve a time resolution of 27 ps combining with high-speed waveform sampling method. 
650 4 |a Front-end electronics for detector readout 
650 4 |a Gaseous detectors 
650 4 |a Instrumentation and methods for time-of-flight (TOF) spectroscopy 
650 4 |a resistive plate chamber 
650 4 |a time-of-flight 
700 1 |a Yue, Xiaoguang  |e VerfasserIn  |0 (DE-588)1183954956  |0 (DE-627)1663423164  |4 aut 
700 1 |a Zeng, M.  |e VerfasserIn  |4 aut 
700 1 |a Cang, J.  |e VerfasserIn  |4 aut 
700 1 |a Li, Z.  |e VerfasserIn  |4 aut 
700 1 |a Wang, Y.  |e VerfasserIn  |4 aut 
700 1 |a Yu, Y.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Journal of Instrumentation  |d London : Inst. of Physics, 2006  |g 15(2020,2) Artikel-Nummer P02006, ? Seiten  |h Online-Ressource  |w (DE-627)512298181  |w (DE-600)2235672-1  |w (DE-576)256442541  |x 1748-0221  |7 nnas  |a Design of an optimised preamplifier for the MRPC detector 
773 1 8 |g volume:15  |g year:2020  |g number:2  |g extent:?  |a Design of an optimised preamplifier for the MRPC detector 
856 4 0 |u https://doi.org/10.1088/1748-0221/15/02/P02006  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200527 
993 |a Article 
994 |a 2020 
998 |g 1183954956  |a Yue, Xiaoguang  |m 1183954956:Yue, Xiaoguang  |d 130000  |d 130700  |e 130000PY1183954956  |e 130700PY1183954956  |k 0/130000/  |k 1/130000/130700/  |p 2 
999 |a KXP-PPN1698901402  |e 3671771747 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"pubHistory":["1.2006 -"],"part":{"volume":"15","text":"15(2020,2) Artikel-Nummer P02006, ? Seiten","extent":"?","year":"2020","issue":"2"},"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 02.11.2020"],"disp":"Design of an optimised preamplifier for the MRPC detectorJournal of Instrumentation","language":["eng"],"recId":"512298181","title":[{"title":"Journal of Instrumentation","title_sort":"Journal of Instrumentation"}],"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisherPlace":"London","dateIssuedDisp":"2006-","dateIssuedKey":"2006","publisher":"Inst. of Physics"}],"id":{"issn":["1748-0221"],"zdb":["2235672-1"],"eki":["512298181"]},"name":{"displayForm":["Institute of Physics Publishing"]}}],"physDesc":[{"extent":"? S."}],"name":{"displayForm":["Y. Li, X. Yue, M. Zeng, J. Cang, Z. Li, Y. Wang, Y. Yu"]},"id":{"doi":["10.1088/1748-0221/15/02/P02006"],"eki":["1698901402"]},"origin":[{"dateIssuedKey":"2020","dateIssuedDisp":"10 February 2020"}],"recId":"1698901402","language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 27.05.2020"],"person":[{"roleDisplay":"VerfasserIn","display":"Li, Yulan","role":"aut","family":"Li","given":"Yulan"},{"role":"aut","display":"Yue, Xiaoguang","roleDisplay":"VerfasserIn","given":"Xiaoguang","family":"Yue"},{"given":"M.","family":"Zeng","role":"aut","roleDisplay":"VerfasserIn","display":"Zeng, M."},{"role":"aut","roleDisplay":"VerfasserIn","display":"Cang, J.","given":"J.","family":"Cang"},{"display":"Li, Z.","roleDisplay":"VerfasserIn","role":"aut","family":"Li","given":"Z."},{"family":"Wang","given":"Y.","display":"Wang, Y.","roleDisplay":"VerfasserIn","role":"aut"},{"family":"Yu","given":"Y.","roleDisplay":"VerfasserIn","display":"Yu, Y.","role":"aut"}],"title":[{"title_sort":"Design of an optimised preamplifier for the MRPC detector","title":"Design of an optimised preamplifier for the MRPC detector"}]} 
SRT |a LIYULANYUEDESIGNOFAN1020