Feasibility of using half-dose Gd-BOPTA for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the knee, compared with standard-dose Gd-DTPA

Background We sought to replace full-dose Gd-DTPA with safer and lower-dose contrast agents for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC). Gd-BOPTA has a lower intrinsic nephrogenic systemic fibrosis risk and a 2-fold higher relaxivity at 3T; thus, the contrast agent dose may be halved,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Rehnitz, Christoph (VerfasserIn) , Do, Thuy (VerfasserIn) , Klaan, Bastian (VerfasserIn) , Burkholder, Iris (VerfasserIn) , Barié, Alexander (VerfasserIn) , Wünnemann, Felix (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Weber, Marc-André (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2020
In: Journal of magnetic resonance imaging
Year: 2020, Jahrgang: 51, Heft: 1, Pages: 144-154
ISSN:1522-2586
DOI:10.1002/jmri.26816
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1002/jmri.26816
Verlag, lizenzpflichtig, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.26816
Volltext
Verfasserangaben:Christoph Rehnitz, Thuy Do, Bastian Klaan, Iris Burkholder, Alexander Barié, Felix Wuennemann, Hans-Ulrich Kauczor, and Marc-André Weber

MARC

LEADER 00000caa a2200000 c 4500
001 1699090238
003 DE-627
005 20220823105416.0
007 cr uuu---uuuuu
008 200602s2020 xx |||||o 00| ||eng c
024 7 |a 10.1002/jmri.26816  |2 doi 
035 |a (DE-627)1699090238 
035 |a (DE-599)KXP1699090238 
035 |a (OCoLC)1341327230 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Rehnitz, Christoph  |d 1976-  |e VerfasserIn  |0 (DE-588)140996990  |0 (DE-627)62381627X  |0 (DE-576)321717368  |4 aut 
245 1 0 |a Feasibility of using half-dose Gd-BOPTA for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the knee, compared with standard-dose Gd-DTPA  |c Christoph Rehnitz, Thuy Do, Bastian Klaan, Iris Burkholder, Alexander Barié, Felix Wuennemann, Hans-Ulrich Kauczor, and Marc-André Weber 
264 1 |c 2020 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published: 29 May 2019 
500 |a Gesehen am 02.06.2020 
520 |a Background We sought to replace full-dose Gd-DTPA with safer and lower-dose contrast agents for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC). Gd-BOPTA has a lower intrinsic nephrogenic systemic fibrosis risk and a 2-fold higher relaxivity at 3T; thus, the contrast agent dose may be halved, further reducing contrast agent-dependent risks. Purpose To compare the feasibility of using half-dose, high-relaxivity Gd-BOPTA vs. standard-dose Gd-DTPA for dGEMRIC. Study Type Prospective observational study. Subjects Eleven healthy volunteers (five women, mean age 25.7 years) and 10 patients with knee pain (three women, mean age 36.7 years; nine with chondromalacia). Field Strength/Sequences 3D T1-weighted volumetric breath-hold examination (VIBE) sequence at 3T. Assessment Knee dGEMRIC was performed twice, first using 0.1 mmol/kg Gd-BOPTA and 4 weeks later using 0.2 mmol/kg Gd-DTPA. Contrast penetration was studied using pre- and 60-120-min postcontrast imaging in volunteers and pre- and 90-min postcontrast imaging in patients. Femoral cartilage lesions were assessed using modified whole-organ MRI scores. Healthy cartilage and partial-thickness lesions were compared using region-of-interest analyses by independent readers. Statistical Tests Linear mixed-effect-models, area under receiver-operating-characteristic curve (AUC) analysis, intraclass correlation (ICC). Results In healthy volunteers, Gd-BOPTA and Gd-DTPA T1-values did not differ significantly at any timepoint (P = 0.164-0.995). In patients, Gd-BOPTA T1-values (743.33 ± 72.015 msec) were higher than Gd-DTPA T1-values (681.24 ± 67.635 msec, P = 0.030). Gd-BOPTA and Gd-DTPA detected chondromalacia areas equally well, with significantly lower T1-values than in healthy cartilage (P < 0.001) and nonsignificantly different AUCs (0.92 and 0.96, P = 0.27). The absolute decrease in T1-values between healthy and pathological cartilage was similar (Gd-BOPTA: 149.59 msec; Gd-DTPA: 149.44 msec, P = 0.99). ICCs were 0.83-0.98 for Gd-BOPTA and 0.80-0.98 for Gd-DTPA. Data Conclusion Gd-BOPTA might be used at half the Gd-DTPA dose in dGEMRIC, with similar contrast penetration and T1-values in healthy cartilage and noninferior detection of cartilage damage. Level of Evidence: 2 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2020;51:144-154. 
650 4 |a cartilage 
650 4 |a comparative study 
650 4 |a dGEMRIC 
650 4 |a Gd-BOPTA 
650 4 |a Gd-DTPA 
650 4 |a knee 
700 1 |a Do, Thuy  |d 1986-  |e VerfasserIn  |0 (DE-588)1156815800  |0 (DE-627)1019763485  |0 (DE-576)502462205  |4 aut 
700 1 |a Klaan, Bastian  |d 1985-  |e VerfasserIn  |0 (DE-588)1155202813  |0 (DE-627)1016543999  |0 (DE-576)501478876  |4 aut 
700 1 |a Burkholder, Iris  |e VerfasserIn  |0 (DE-588)1176548557  |0 (DE-627)104754671X  |0 (DE-576)516671278  |4 aut 
700 1 |a Barié, Alexander  |d 1972-  |e VerfasserIn  |0 (DE-588)131983652  |0 (DE-627)516334611  |0 (DE-576)29887637X  |4 aut 
700 1 |a Wünnemann, Felix  |d 1988-  |e VerfasserIn  |0 (DE-588)1156815983  |0 (DE-627)1019784156  |0 (DE-576)502462388  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Weber, Marc-André  |d 1973-  |e VerfasserIn  |0 (DE-588)142373044  |0 (DE-627)704211432  |0 (DE-576)330376802  |4 aut 
773 0 8 |i Enthalten in  |t Journal of magnetic resonance imaging  |d New York, NY : Wiley-Liss, 1991  |g 51(2020), 1, Seite 144-154  |h Online-Ressource  |w (DE-627)306360039  |w (DE-600)1497154-9  |w (DE-576)114617252  |x 1522-2586  |7 nnas  |a Feasibility of using half-dose Gd-BOPTA for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the knee, compared with standard-dose Gd-DTPA 
773 1 8 |g volume:51  |g year:2020  |g number:1  |g pages:144-154  |g extent:11  |a Feasibility of using half-dose Gd-BOPTA for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the knee, compared with standard-dose Gd-DTPA 
856 4 0 |u https://doi.org/10.1002/jmri.26816  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.26816  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200602 
993 |a Article 
994 |a 2020 
998 |g 142373044  |a Weber, Marc-André  |m 142373044:Weber, Marc-André  |d 50000  |e 50000PW142373044  |k 0/50000/  |p 8  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 1156815983  |a Wünnemann, Felix  |m 1156815983:Wünnemann, Felix  |d 50000  |e 50000PW1156815983  |k 0/50000/  |p 6 
998 |g 131983652  |a Barié, Alexander  |m 131983652:Barié, Alexander  |d 910000  |d 911400  |e 910000PB131983652  |e 911400PB131983652  |k 0/910000/  |k 1/910000/911400/  |p 5 
998 |g 1176548557  |a Burkholder, Iris  |m 1176548557:Burkholder, Iris  |d 140000  |e 140000PB1176548557  |k 0/140000/  |p 4 
998 |g 1155202813  |a Klaan, Bastian  |m 1155202813:Klaan, Bastian  |d 50000  |e 50000PK1155202813  |k 0/50000/  |p 3 
998 |g 1156815800  |a Do, Thuy  |m 1156815800:Do, Thuy  |d 910000  |d 911400  |e 910000PD1156815800  |e 911400PD1156815800  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 140996990  |a Rehnitz, Christoph  |m 140996990:Rehnitz, Christoph  |d 910000  |d 911400  |d 50000  |e 910000PR140996990  |e 911400PR140996990  |e 50000PR140996990  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1699090238  |e 368131943X 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Christoph Rehnitz, Thuy Do, Bastian Klaan, Iris Burkholder, Alexander Barié, Felix Wuennemann, Hans-Ulrich Kauczor, and Marc-André Weber"]},"id":{"doi":["10.1002/jmri.26816"],"eki":["1699090238"]},"physDesc":[{"extent":"11 S."}],"recId":"1699090238","origin":[{"dateIssuedKey":"2020","dateIssuedDisp":"2020"}],"person":[{"family":"Rehnitz","given":"Christoph","role":"aut","display":"Rehnitz, Christoph"},{"display":"Do, Thuy","given":"Thuy","role":"aut","family":"Do"},{"display":"Klaan, Bastian","family":"Klaan","given":"Bastian","role":"aut"},{"family":"Burkholder","given":"Iris","role":"aut","display":"Burkholder, Iris"},{"role":"aut","given":"Alexander","family":"Barié","display":"Barié, Alexander"},{"role":"aut","given":"Felix","family":"Wünnemann","display":"Wünnemann, Felix"},{"role":"aut","given":"Hans-Ulrich","family":"Kauczor","display":"Kauczor, Hans-Ulrich"},{"given":"Marc-André","role":"aut","family":"Weber","display":"Weber, Marc-André"}],"relHost":[{"disp":"Feasibility of using half-dose Gd-BOPTA for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the knee, compared with standard-dose Gd-DTPAJournal of magnetic resonance imaging","physDesc":[{"extent":"Online-Ressource"}],"recId":"306360039","note":["Gesehen am 28.02.08","Fortsetzung der CD-ROM-Ausgabe"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"title_sort":"Journal of magnetic resonance imaging","title":"Journal of magnetic resonance imaging","subtitle":"JMRI ; an official journal of the International Society for Magnetic Resonance in Medicine"}],"origin":[{"publisher":"Wiley-Liss","publisherPlace":"New York, NY","dateIssuedKey":"1991","dateIssuedDisp":"1991-"}],"part":{"year":"2020","volume":"51","pages":"144-154","issue":"1","text":"51(2020), 1, Seite 144-154","extent":"11"},"id":{"eki":["306360039"],"issn":["1522-2586"],"zdb":["1497154-9"],"doi":["10.1002/(ISSN)1522-2586"]},"titleAlt":[{"title":"JMRI"}],"pubHistory":["1.1991 -"]}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Published: 29 May 2019","Gesehen am 02.06.2020"],"title":[{"title":"Feasibility of using half-dose Gd-BOPTA for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the knee, compared with standard-dose Gd-DTPA","title_sort":"Feasibility of using half-dose Gd-BOPTA for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the knee, compared with standard-dose Gd-DTPA"}]} 
SRT |a REHNITZCHRFEASIBILIT2020