Feasibility of using half-dose Gd-BOPTA for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the knee, compared with standard-dose Gd-DTPA
Background We sought to replace full-dose Gd-DTPA with safer and lower-dose contrast agents for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC). Gd-BOPTA has a lower intrinsic nephrogenic systemic fibrosis risk and a 2-fold higher relaxivity at 3T; thus, the contrast agent dose may be halved,...
Gespeichert in:
| Hauptverfasser: | , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2020
|
| In: |
Journal of magnetic resonance imaging
Year: 2020, Jahrgang: 51, Heft: 1, Pages: 144-154 |
| ISSN: | 1522-2586 |
| DOI: | 10.1002/jmri.26816 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1002/jmri.26816 Verlag, lizenzpflichtig, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.26816 |
| Verfasserangaben: | Christoph Rehnitz, Thuy Do, Bastian Klaan, Iris Burkholder, Alexander Barié, Felix Wuennemann, Hans-Ulrich Kauczor, and Marc-André Weber |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1699090238 | ||
| 003 | DE-627 | ||
| 005 | 20220823105416.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200602s2020 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1002/jmri.26816 |2 doi | |
| 035 | |a (DE-627)1699090238 | ||
| 035 | |a (DE-599)KXP1699090238 | ||
| 035 | |a (OCoLC)1341327230 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Rehnitz, Christoph |d 1976- |e VerfasserIn |0 (DE-588)140996990 |0 (DE-627)62381627X |0 (DE-576)321717368 |4 aut | |
| 245 | 1 | 0 | |a Feasibility of using half-dose Gd-BOPTA for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the knee, compared with standard-dose Gd-DTPA |c Christoph Rehnitz, Thuy Do, Bastian Klaan, Iris Burkholder, Alexander Barié, Felix Wuennemann, Hans-Ulrich Kauczor, and Marc-André Weber |
| 264 | 1 | |c 2020 | |
| 300 | |a 11 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Published: 29 May 2019 | ||
| 500 | |a Gesehen am 02.06.2020 | ||
| 520 | |a Background We sought to replace full-dose Gd-DTPA with safer and lower-dose contrast agents for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC). Gd-BOPTA has a lower intrinsic nephrogenic systemic fibrosis risk and a 2-fold higher relaxivity at 3T; thus, the contrast agent dose may be halved, further reducing contrast agent-dependent risks. Purpose To compare the feasibility of using half-dose, high-relaxivity Gd-BOPTA vs. standard-dose Gd-DTPA for dGEMRIC. Study Type Prospective observational study. Subjects Eleven healthy volunteers (five women, mean age 25.7 years) and 10 patients with knee pain (three women, mean age 36.7 years; nine with chondromalacia). Field Strength/Sequences 3D T1-weighted volumetric breath-hold examination (VIBE) sequence at 3T. Assessment Knee dGEMRIC was performed twice, first using 0.1 mmol/kg Gd-BOPTA and 4 weeks later using 0.2 mmol/kg Gd-DTPA. Contrast penetration was studied using pre- and 60-120-min postcontrast imaging in volunteers and pre- and 90-min postcontrast imaging in patients. Femoral cartilage lesions were assessed using modified whole-organ MRI scores. Healthy cartilage and partial-thickness lesions were compared using region-of-interest analyses by independent readers. Statistical Tests Linear mixed-effect-models, area under receiver-operating-characteristic curve (AUC) analysis, intraclass correlation (ICC). Results In healthy volunteers, Gd-BOPTA and Gd-DTPA T1-values did not differ significantly at any timepoint (P = 0.164-0.995). In patients, Gd-BOPTA T1-values (743.33 ± 72.015 msec) were higher than Gd-DTPA T1-values (681.24 ± 67.635 msec, P = 0.030). Gd-BOPTA and Gd-DTPA detected chondromalacia areas equally well, with significantly lower T1-values than in healthy cartilage (P < 0.001) and nonsignificantly different AUCs (0.92 and 0.96, P = 0.27). The absolute decrease in T1-values between healthy and pathological cartilage was similar (Gd-BOPTA: 149.59 msec; Gd-DTPA: 149.44 msec, P = 0.99). ICCs were 0.83-0.98 for Gd-BOPTA and 0.80-0.98 for Gd-DTPA. Data Conclusion Gd-BOPTA might be used at half the Gd-DTPA dose in dGEMRIC, with similar contrast penetration and T1-values in healthy cartilage and noninferior detection of cartilage damage. Level of Evidence: 2 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2020;51:144-154. | ||
| 650 | 4 | |a cartilage | |
| 650 | 4 | |a comparative study | |
| 650 | 4 | |a dGEMRIC | |
| 650 | 4 | |a Gd-BOPTA | |
| 650 | 4 | |a Gd-DTPA | |
| 650 | 4 | |a knee | |
| 700 | 1 | |a Do, Thuy |d 1986- |e VerfasserIn |0 (DE-588)1156815800 |0 (DE-627)1019763485 |0 (DE-576)502462205 |4 aut | |
| 700 | 1 | |a Klaan, Bastian |d 1985- |e VerfasserIn |0 (DE-588)1155202813 |0 (DE-627)1016543999 |0 (DE-576)501478876 |4 aut | |
| 700 | 1 | |a Burkholder, Iris |e VerfasserIn |0 (DE-588)1176548557 |0 (DE-627)104754671X |0 (DE-576)516671278 |4 aut | |
| 700 | 1 | |a Barié, Alexander |d 1972- |e VerfasserIn |0 (DE-588)131983652 |0 (DE-627)516334611 |0 (DE-576)29887637X |4 aut | |
| 700 | 1 | |a Wünnemann, Felix |d 1988- |e VerfasserIn |0 (DE-588)1156815983 |0 (DE-627)1019784156 |0 (DE-576)502462388 |4 aut | |
| 700 | 1 | |a Kauczor, Hans-Ulrich |d 1962- |e VerfasserIn |0 (DE-588)139267123 |0 (DE-627)70327113X |0 (DE-576)310955327 |4 aut | |
| 700 | 1 | |a Weber, Marc-André |d 1973- |e VerfasserIn |0 (DE-588)142373044 |0 (DE-627)704211432 |0 (DE-576)330376802 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of magnetic resonance imaging |d New York, NY : Wiley-Liss, 1991 |g 51(2020), 1, Seite 144-154 |h Online-Ressource |w (DE-627)306360039 |w (DE-600)1497154-9 |w (DE-576)114617252 |x 1522-2586 |7 nnas |a Feasibility of using half-dose Gd-BOPTA for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the knee, compared with standard-dose Gd-DTPA |
| 773 | 1 | 8 | |g volume:51 |g year:2020 |g number:1 |g pages:144-154 |g extent:11 |a Feasibility of using half-dose Gd-BOPTA for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the knee, compared with standard-dose Gd-DTPA |
| 856 | 4 | 0 | |u https://doi.org/10.1002/jmri.26816 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.26816 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200602 | ||
| 993 | |a Article | ||
| 994 | |a 2020 | ||
| 998 | |g 142373044 |a Weber, Marc-André |m 142373044:Weber, Marc-André |d 50000 |e 50000PW142373044 |k 0/50000/ |p 8 |y j | ||
| 998 | |g 139267123 |a Kauczor, Hans-Ulrich |m 139267123:Kauczor, Hans-Ulrich |d 910000 |d 911400 |e 910000PK139267123 |e 911400PK139267123 |k 0/910000/ |k 1/910000/911400/ |p 7 | ||
| 998 | |g 1156815983 |a Wünnemann, Felix |m 1156815983:Wünnemann, Felix |d 50000 |e 50000PW1156815983 |k 0/50000/ |p 6 | ||
| 998 | |g 131983652 |a Barié, Alexander |m 131983652:Barié, Alexander |d 910000 |d 911400 |e 910000PB131983652 |e 911400PB131983652 |k 0/910000/ |k 1/910000/911400/ |p 5 | ||
| 998 | |g 1176548557 |a Burkholder, Iris |m 1176548557:Burkholder, Iris |d 140000 |e 140000PB1176548557 |k 0/140000/ |p 4 | ||
| 998 | |g 1155202813 |a Klaan, Bastian |m 1155202813:Klaan, Bastian |d 50000 |e 50000PK1155202813 |k 0/50000/ |p 3 | ||
| 998 | |g 1156815800 |a Do, Thuy |m 1156815800:Do, Thuy |d 910000 |d 911400 |e 910000PD1156815800 |e 911400PD1156815800 |k 0/910000/ |k 1/910000/911400/ |p 2 | ||
| 998 | |g 140996990 |a Rehnitz, Christoph |m 140996990:Rehnitz, Christoph |d 910000 |d 911400 |d 50000 |e 910000PR140996990 |e 911400PR140996990 |e 50000PR140996990 |k 0/910000/ |k 1/910000/911400/ |k 0/50000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1699090238 |e 368131943X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"name":{"displayForm":["Christoph Rehnitz, Thuy Do, Bastian Klaan, Iris Burkholder, Alexander Barié, Felix Wuennemann, Hans-Ulrich Kauczor, and Marc-André Weber"]},"id":{"doi":["10.1002/jmri.26816"],"eki":["1699090238"]},"physDesc":[{"extent":"11 S."}],"recId":"1699090238","origin":[{"dateIssuedKey":"2020","dateIssuedDisp":"2020"}],"person":[{"family":"Rehnitz","given":"Christoph","role":"aut","display":"Rehnitz, Christoph"},{"display":"Do, Thuy","given":"Thuy","role":"aut","family":"Do"},{"display":"Klaan, Bastian","family":"Klaan","given":"Bastian","role":"aut"},{"family":"Burkholder","given":"Iris","role":"aut","display":"Burkholder, Iris"},{"role":"aut","given":"Alexander","family":"Barié","display":"Barié, Alexander"},{"role":"aut","given":"Felix","family":"Wünnemann","display":"Wünnemann, Felix"},{"role":"aut","given":"Hans-Ulrich","family":"Kauczor","display":"Kauczor, Hans-Ulrich"},{"given":"Marc-André","role":"aut","family":"Weber","display":"Weber, Marc-André"}],"relHost":[{"disp":"Feasibility of using half-dose Gd-BOPTA for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the knee, compared with standard-dose Gd-DTPAJournal of magnetic resonance imaging","physDesc":[{"extent":"Online-Ressource"}],"recId":"306360039","note":["Gesehen am 28.02.08","Fortsetzung der CD-ROM-Ausgabe"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"title_sort":"Journal of magnetic resonance imaging","title":"Journal of magnetic resonance imaging","subtitle":"JMRI ; an official journal of the International Society for Magnetic Resonance in Medicine"}],"origin":[{"publisher":"Wiley-Liss","publisherPlace":"New York, NY","dateIssuedKey":"1991","dateIssuedDisp":"1991-"}],"part":{"year":"2020","volume":"51","pages":"144-154","issue":"1","text":"51(2020), 1, Seite 144-154","extent":"11"},"id":{"eki":["306360039"],"issn":["1522-2586"],"zdb":["1497154-9"],"doi":["10.1002/(ISSN)1522-2586"]},"titleAlt":[{"title":"JMRI"}],"pubHistory":["1.1991 -"]}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Published: 29 May 2019","Gesehen am 02.06.2020"],"title":[{"title":"Feasibility of using half-dose Gd-BOPTA for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the knee, compared with standard-dose Gd-DTPA","title_sort":"Feasibility of using half-dose Gd-BOPTA for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the knee, compared with standard-dose Gd-DTPA"}]} | ||
| SRT | |a REHNITZCHRFEASIBILIT2020 | ||