Resistance to fracture in fixed dental prostheses over cemented and screw-retained implant-supported zirconia cantilevers in the anterior region: an in vitro study
Stefan Rues, MSc/Stefanie Kappel, PhD, DDS/Dorothee Ruckes, BSc/Peter Rammelsberg, PhD, DDS/Andreas Zenthöfer, PhD, DDS: Purpose: To evaluate the resistance to fracture in cantilevered fixed dental prostheses (cFDPs) of single implant-supported - zirconia cantilevers in the anterior region. Materi...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
May/June 2020
|
| In: |
The international journal of oral & maxillofacial implants
Year: 2020, Jahrgang: 35, Heft: 3, Pages: 521-529 |
| ISSN: | 1942-4434 |
| DOI: | 10.11607/jomi.7899 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: http://www.quintpub.com/journals/omi/abstract.php?iss2_id=1680&article_id=20282#.XtiXN8BCQ2w Verlag: https://doi.org/10.11607/jomi.7899 |
| Verfasserangaben: | Stefan Rues, Stefanie Kappel, Dorothee Ruckes, Peter Rammelsberg, Andreas Zenthöfer |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1699761701 | ||
| 003 | DE-627 | ||
| 005 | 20220818111921.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200604s2020 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.11607/jomi.7899 |2 doi | |
| 035 | |a (DE-627)1699761701 | ||
| 035 | |a (DE-599)KXP1699761701 | ||
| 035 | |a (OCoLC)1341328464 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Rues, Stefan |e VerfasserIn |0 (DE-588)1054444927 |0 (DE-627)792098331 |0 (DE-576)410292168 |4 aut | |
| 245 | 1 | 0 | |a Resistance to fracture in fixed dental prostheses over cemented and screw-retained implant-supported zirconia cantilevers in the anterior region |b an in vitro study |c Stefan Rues, Stefanie Kappel, Dorothee Ruckes, Peter Rammelsberg, Andreas Zenthöfer |
| 264 | 1 | |c May/June 2020 | |
| 300 | |a 9 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 04.06.2020 | ||
| 520 | |a Stefan Rues, MSc/Stefanie Kappel, PhD, DDS/Dorothee Ruckes, BSc/Peter Rammelsberg, PhD, DDS/Andreas Zenthöfer, PhD, DDS: Purpose: To evaluate the resistance to fracture in cantilevered fixed dental prostheses (cFDPs) of single implant-supported - zirconia cantilevers in the anterior region. Materials and Methods: Thirty-two cemented and solely screw-retained cFDPs - consisting of an implant-supported crown replacing the central incisor and an attached cantilever unit in the position - of the lateral incisor in the maxilla were constructed by computer-aided design (CAD) and machined by computer-aided - manufacturing (CAM). For the cemented solution, a cFDP was designed on top of a customized abutment luted - to an adhesive base. For screw-retained cFDPs, abutment, cement gap, and restoration of the cementable design - were combined. All cFDPs were veneered manually on the facial side. Half of the samples underwent artificial aging - (thermocycling and chewing simulation) before fracture tests were conducted with loads applied to the pontic either - parallel to the implant axis (axial loading on the pontic) or tilted lingually by α = 45 degrees (oblique loading on the - pontic). Thus, there were eight groups differing in cFDP design, artificial aging, and load application (n = 8/group). If - fracture (F<sub>u,total</sub>) occurred within the implant components, the adhesive base was replaced by a cast CoCr base, and the - cFDP’s fracture resistance (F<sub>u,cFDP</sub>) was also determined. Using statistical analyses (SPSS 24, IBM), factors affecting fracture - resistance were identified. Results: F<sub>u,total</sub> was mainly correlated to screw fractures and therefore not affected by cFDP - design. Oblique loading on the pontic (F<sub>u,total</sub> = 231 N - 352 N), however, led to a significant (P < .001) decrease in ultimate - load compared with axial loading on the pontic (F<sub>u,total</sub> = 611 N - 815 N). In relation to F<sub>u,total</sub>, F<sub>u,cFDP</sub> was approximately - twice as high for both loading conditions. Conclusion: When relating the results to maximum occlusal forces exerted - in the maxillary anterior region, single implant-supported cFDPs can be a viable restorative treatment option. | ||
| 700 | 1 | |a Kappel, Stefanie |d 1980- |e VerfasserIn |0 (DE-588)13162590X |0 (DE-627)707687101 |0 (DE-576)298633876 |4 aut | |
| 700 | 1 | |a Ruckes, Dorothee |e VerfasserIn |4 aut | |
| 700 | 1 | |a Rammelsberg, Peter |d 1959- |e VerfasserIn |0 (DE-588)122469836 |0 (DE-627)705920836 |0 (DE-576)293285640 |4 aut | |
| 700 | 1 | |a Zenthöfer, Andreas |d 1982- |e VerfasserIn |0 (DE-588)1046882449 |0 (DE-627)77729270X |0 (DE-576)400200740 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t The international journal of oral & maxillofacial implants |d Batavia : Quintessence Publishing, 1986 |g 35(2020), 3, Seite 521-529 |h Online-Ressource |w (DE-627)325294399 |w (DE-600)2035048-X |w (DE-576)094477221 |x 1942-4434 |7 nnas |a Resistance to fracture in fixed dental prostheses over cemented and screw-retained implant-supported zirconia cantilevers in the anterior region an in vitro study |
| 773 | 1 | 8 | |g volume:35 |g year:2020 |g number:3 |g pages:521-529 |g extent:9 |a Resistance to fracture in fixed dental prostheses over cemented and screw-retained implant-supported zirconia cantilevers in the anterior region an in vitro study |
| 856 | 4 | 0 | |u http://www.quintpub.com/journals/omi/abstract.php?iss2_id=1680&article_id=20282#.XtiXN8BCQ2w |x Verlag |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://doi.org/10.11607/jomi.7899 |x Verlag |
| 951 | |a AR | ||
| 992 | |a 20200604 | ||
| 993 | |a Article | ||
| 994 | |a 2020 | ||
| 998 | |g 1046882449 |a Zenthöfer, Andreas |m 1046882449:Zenthöfer, Andreas |d 910000 |d 910800 |e 910000PZ1046882449 |e 910800PZ1046882449 |k 0/910000/ |k 1/910000/910800/ |p 5 |y j | ||
| 998 | |g 122469836 |a Rammelsberg, Peter |m 122469836:Rammelsberg, Peter |d 910000 |d 910800 |e 910000PR122469836 |e 910800PR122469836 |k 0/910000/ |k 1/910000/910800/ |p 4 | ||
| 998 | |g 13162590X |a Kappel, Stefanie |m 13162590X:Kappel, Stefanie |d 910000 |d 910800 |e 910000PK13162590X |e 910800PK13162590X |k 0/910000/ |k 1/910000/910800/ |p 2 | ||
| 998 | |g 1054444927 |a Rues, Stefan |m 1054444927:Rues, Stefan |d 910000 |d 910800 |e 910000PR1054444927 |e 910800PR1054444927 |k 0/910000/ |k 1/910000/910800/ |p 1 |x j | ||
| 999 | |a KXP-PPN1699761701 |e 3682454624 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"recId":"1699761701","note":["Gesehen am 04.06.2020"],"name":{"displayForm":["Stefan Rues, Stefanie Kappel, Dorothee Ruckes, Peter Rammelsberg, Andreas Zenthöfer"]},"language":["eng"],"id":{"doi":["10.11607/jomi.7899"],"eki":["1699761701"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedDisp":"May/June 2020","dateIssuedKey":"2020"}],"relHost":[{"disp":"Resistance to fracture in fixed dental prostheses over cemented and screw-retained implant-supported zirconia cantilevers in the anterior region an in vitro studyThe international journal of oral & maxillofacial implants","pubHistory":["1.1986 -"],"note":["Gesehen am 29.7.23"],"recId":"325294399","origin":[{"dateIssuedDisp":"[1986]-","publisherPlace":"Batavia","publisher":"Quintessence Publishing"}],"titleAlt":[{"title":"JOMI"}],"title":[{"title":"The international journal of oral & maxillofacial implants","subtitle":"official journal of the Academy of Osseointegration","title_sort":"international journal of oral & maxillofacial implants"}],"physDesc":[{"extent":"Online-Ressource"}],"part":{"pages":"521-529","text":"35(2020), 3, Seite 521-529","volume":"35","issue":"3","year":"2020","extent":"9"},"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"id":{"issn":["1942-4434"],"zdb":["2035048-X"],"eki":["325294399"]},"corporate":[{"display":"Academy of Osseointegration","role":"isb"}]}],"physDesc":[{"extent":"9 S."}],"person":[{"display":"Rues, Stefan","family":"Rues","given":"Stefan","role":"aut"},{"display":"Kappel, Stefanie","family":"Kappel","given":"Stefanie","role":"aut"},{"role":"aut","given":"Dorothee","display":"Ruckes, Dorothee","family":"Ruckes"},{"given":"Peter","family":"Rammelsberg","display":"Rammelsberg, Peter","role":"aut"},{"display":"Zenthöfer, Andreas","family":"Zenthöfer","given":"Andreas","role":"aut"}],"title":[{"subtitle":"an in vitro study","title":"Resistance to fracture in fixed dental prostheses over cemented and screw-retained implant-supported zirconia cantilevers in the anterior region","title_sort":"Resistance to fracture in fixed dental prostheses over cemented and screw-retained implant-supported zirconia cantilevers in the anterior region"}]} | ||
| SRT | |a RUESSTEFANRESISTANCE2020 | ||