Pre-clinical evaluation of dual-layer spectral computed tomography-based stopping power prediction for particle therapy planning at the Heidelberg Ion Beam Therapy Center

Accurate beam range prediction during clinical treatment planning is key to improve targeted dose delivery in proton and heavy ion therapy. A substantial source of beam range uncertainty is the prediction of ion stopping power ratio (SPR) relative to water from an empirical calibration based on conv...

Full description

Saved in:
Bibliographic Details
Main Authors: Faller, Friderike K. (Author) , Mein, Stewart (Author) , Ackermann, Benjamin (Author) , Debus, Jürgen (Author) , Stiller, Wolfram (Author) , Mairani, Andrea (Author)
Format: Article (Journal)
Language:English
Published: 24 April 2020
In: Physics in medicine and biology
Year: 2020, Volume: 65, Issue: 9
ISSN:1361-6560
DOI:10.1088/1361-6560/ab735e
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1088/1361-6560/ab735e
Get full text
Author Notes:Friderike K. Faller, Stewart Mein, Benjamin Ackermann, Jürgen Debus, Wolfram Stiller, Andrea Mairani

MARC

LEADER 00000caa a2200000 c 4500
001 1699787638
003 DE-627
005 20220818112347.0
007 cr uuu---uuuuu
008 200604s2020 xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/ab735e  |2 doi 
035 |a (DE-627)1699787638 
035 |a (DE-599)KXP1699787638 
035 |a (OCoLC)1341328552 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Faller, Friderike K.  |e VerfasserIn  |0 (DE-588)1211509001  |0 (DE-627)1699789231  |4 aut 
245 1 0 |a Pre-clinical evaluation of dual-layer spectral computed tomography-based stopping power prediction for particle therapy planning at the Heidelberg Ion Beam Therapy Center  |c Friderike K. Faller, Stewart Mein, Benjamin Ackermann, Jürgen Debus, Wolfram Stiller, Andrea Mairani 
264 1 |c 24 April 2020 
300 |a 14 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 04.06.2020 
520 |a Accurate beam range prediction during clinical treatment planning is key to improve targeted dose delivery in proton and heavy ion therapy. A substantial source of beam range uncertainty is the prediction of ion stopping power ratio (SPR) relative to water from an empirical calibration based on conventional x-ray computed tomography (CT) used in clinical practice today. The aim of this study was to investigate the potential of a novel spectral CT imaging technique based on a dual-layer detector-based approach to improve the SPR prediction for particle therapy treatment planning, an improvement that would minimize the beam range uncertainty and allow for reduced safety margins in the patient. Using calibrated and validated maps of electron density and effective atomic number from spectral CT data, predicted SPR values in tissue substitutes were within a mean accuracy of 0.6% compared to measured SPR and showed substantially better agreement with measured data compared to standard CT-number-to-SPR calibration. The accuracy of SPR was not affected by CT acquisition settings, reconstruction parameters, phantom size, and type. Additionally, various spectral CT conversion algorithms were compared to determine the most accurate prediction method. Dosimetric validation of the developed method using a half-head anthropomorphic phantom in a routine-like setting indicated that SPR prediction with dual-layer spectral CT outperforms the clinical single-energy CT standard with a range prediction improvement of 1 mm. This study demonstrated in homogeneous and heterogeneous phantoms that spectral CT is feasible for particle therapy planning to improve range estimates for high-precision particle therapy. 
700 1 |a Mein, Stewart  |d 1989-  |e VerfasserIn  |0 (DE-588)1156925304  |0 (DE-627)1019871873  |0 (DE-576)502506105  |4 aut 
700 1 |a Ackermann, Benjamin  |d 1979-  |e VerfasserIn  |0 (DE-588)1066758417  |0 (DE-627)817931562  |0 (DE-576)426134141  |4 aut 
700 1 |a Debus, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1022671421  |0 (DE-627)717025780  |0 (DE-576)365774944  |4 aut 
700 1 |a Stiller, Wolfram  |d 1976-  |e VerfasserIn  |0 (DE-588)105822672X  |0 (DE-627)796627495  |0 (DE-576)414249496  |4 aut 
700 1 |a Mairani, Andrea  |e VerfasserIn  |0 (DE-588)1116742179  |0 (DE-627)870669281  |0 (DE-576)478592493  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 65(2020,9) Artikel-Nummer 095007, 14 Seiten  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Pre-clinical evaluation of dual-layer spectral computed tomography-based stopping power prediction for particle therapy planning at the Heidelberg Ion Beam Therapy Center 
773 1 8 |g volume:65  |g year:2020  |g number:9  |g extent:14  |a Pre-clinical evaluation of dual-layer spectral computed tomography-based stopping power prediction for particle therapy planning at the Heidelberg Ion Beam Therapy Center 
856 4 0 |u https://doi.org/10.1088/1361-6560/ab735e  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200604 
993 |a Article 
994 |a 2020 
998 |g 1116742179  |a Mairani, Andrea  |m 1116742179:Mairani, Andrea  |d 910000  |d 950000  |d 950400  |e 910000PM1116742179  |e 950000PM1116742179  |e 950400PM1116742179  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 6  |y j 
998 |g 105822672X  |a Stiller, Wolfram  |m 105822672X:Stiller, Wolfram  |d 910000  |d 911400  |e 910000PS105822672X  |e 911400PS105822672X  |k 0/910000/  |k 1/910000/911400/  |p 5 
998 |g 1022671421  |a Debus, Jürgen  |m 1022671421:Debus, Jürgen  |d 910000  |d 911400  |e 910000PD1022671421  |e 911400PD1022671421  |k 0/910000/  |k 1/910000/911400/  |p 4 
998 |g 1066758417  |a Ackermann, Benjamin  |m 1066758417:Ackermann, Benjamin  |d 910000  |d 950000  |d 950400  |e 910000PA1066758417  |e 950000PA1066758417  |e 950400PA1066758417  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 3 
998 |g 1156925304  |a Mein, Stewart  |m 1156925304:Mein, Stewart  |d 130000  |e 130000PM1156925304  |k 0/130000/  |p 2 
998 |g 1211509001  |a Faller, Friderike  |m 1211509001:Faller, Friderike  |d 910000  |d 911400  |e 910000PF1211509001  |e 911400PF1211509001  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1699787638  |e 3682549064 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Friderike K. Faller, Stewart Mein, Benjamin Ackermann, Jürgen Debus, Wolfram Stiller, Andrea Mairani"]},"origin":[{"dateIssuedDisp":"24 April 2020","dateIssuedKey":"2020"}],"id":{"eki":["1699787638"],"doi":["10.1088/1361-6560/ab735e"]},"recId":"1699787638","type":{"media":"Online-Ressource","bibl":"article-journal"},"person":[{"given":"Friderike K.","display":"Faller, Friderike K.","role":"aut","family":"Faller"},{"display":"Mein, Stewart","family":"Mein","role":"aut","given":"Stewart"},{"given":"Benjamin","role":"aut","family":"Ackermann","display":"Ackermann, Benjamin"},{"given":"Jürgen","display":"Debus, Jürgen","family":"Debus","role":"aut"},{"given":"Wolfram","display":"Stiller, Wolfram","family":"Stiller","role":"aut"},{"given":"Andrea","display":"Mairani, Andrea","role":"aut","family":"Mairani"}],"note":["Gesehen am 04.06.2020"],"language":["eng"],"physDesc":[{"extent":"14 S."}],"title":[{"title":"Pre-clinical evaluation of dual-layer spectral computed tomography-based stopping power prediction for particle therapy planning at the Heidelberg Ion Beam Therapy Center","title_sort":"Pre-clinical evaluation of dual-layer spectral computed tomography-based stopping power prediction for particle therapy planning at the Heidelberg Ion Beam Therapy Center"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Physics in medicine and biology","subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title":"Physics in medicine and biology"}],"part":{"issue":"9","volume":"65","year":"2020","text":"65(2020,9) Artikel-Nummer 095007, 14 Seiten","extent":"14"},"pubHistory":["1.1956 -"],"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"language":["eng"],"disp":"Pre-clinical evaluation of dual-layer spectral computed tomography-based stopping power prediction for particle therapy planning at the Heidelberg Ion Beam Therapy CenterPhysics in medicine and biology","origin":[{"publisherPlace":"Bristol","dateIssuedKey":"1956","dateIssuedDisp":"1956-","publisher":"IOP Publ."}],"id":{"zdb":["1473501-5"],"eki":["269016163"],"issn":["1361-6560"]},"recId":"269016163","type":{"media":"Online-Ressource","bibl":"periodical"}}]} 
SRT |a FALLERFRIDPRECLINICA2420