Off-resonance magnetic resonance angiography improves visualization of in-stent lumen in peripheral nitinol stents compared to conventional T1-weighted acquisitions: an in vitro comparison study

To compare the value of inversion recovery with on-resonant water suppression (IRON) to conventional T1-weighted (T1w) MRA and computed tomography angiography (CTA) for visualization of peripheral nitinol stents. We visualized 14 different peripheral nitinol stents in vitro both using Gadolinium (Gd...

Full description

Saved in:
Bibliographic Details
Main Authors: Gitsioudis, Gitsios (Author) , Fortner, Philipp (Author) , Stuber, Matthias (Author) , Missiou, Anna (Author) , André, Florian (Author) , Müller, Oliver J. (Author) , Katus, Hugo (Author) , Korosoglou, Grigorios (Author)
Format: Article (Journal)
Language:English
Published: 17 August 2016
In: The international journal of cardiovascular imaging
Year: 2016, Volume: 32, Issue: 11, Pages: 1645-1655
ISSN:1875-8312
DOI:10.1007/s10554-016-0955-4
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s10554-016-0955-4
Get full text
Author Notes:Gitsios Gitsioudis, Philipp Fortner, Matthias Stuber, Anna Missiou, Florian Andre, Oliver J. Müller, Hugo A. Katus, Grigorios Korosoglou

MARC

LEADER 00000caa a2200000 c 4500
001 1700503545
003 DE-627
005 20220818120954.0
007 cr uuu---uuuuu
008 200612s2016 xx |||||o 00| ||eng c
024 7 |a 10.1007/s10554-016-0955-4  |2 doi 
035 |a (DE-627)1700503545 
035 |a (DE-599)KXP1700503545 
035 |a (OCoLC)1341339258 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Gitsioudis, Gitsios  |d 1981-  |e VerfasserIn  |0 (DE-588)138256209  |0 (DE-627)600669149  |0 (DE-576)30648174X  |4 aut 
245 1 0 |a Off-resonance magnetic resonance angiography improves visualization of in-stent lumen in peripheral nitinol stents compared to conventional T1-weighted acquisitions  |b an in vitro comparison study  |c Gitsios Gitsioudis, Philipp Fortner, Matthias Stuber, Anna Missiou, Florian Andre, Oliver J. Müller, Hugo A. Katus, Grigorios Korosoglou 
264 1 |c 17 August 2016 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 12.06.2020 
520 |a To compare the value of inversion recovery with on-resonant water suppression (IRON) to conventional T1-weighted (T1w) MRA and computed tomography angiography (CTA) for visualization of peripheral nitinol stents. We visualized 14 different peripheral nitinol stents in vitro both using Gadolinium (Gd) and ultrasmall superparamagnetic iron nanoparticles (USPIOs) for conventional T1w and IRON-MRA using clinical grade 1.5T MR scanner and iodinated contrast material for CTA using a 256-slice CT scanner. Parameter assessment included signal- and contrast-to-noise ratio (S/CNR), relative in-stent signal and artificial lumen narrowing. X-ray angiography served as gold standard for diameter assessment. Gd-enhanced IRON-MRA exhibited highest in-stent SNR and CNR values compared to conventional T1w MRA (IRON (Gd/USPIO): SNR = 30 ± 3/21 ± 2, CNR = 23 ± 2/14 ± 1; T1w: SNR = 16 ± 1/14 ± 2, CNR = 12 ± 1/10 ± 1, all p < 0.05). Furthermore, IRON-MRA achieved highest relative in-stent signal both using Gd and USPIO (IRON (Gd/USPIO): 121 ± 8 %/103 ± 6 %; T1w: 73 ± 2 %/66 ± 4 %; CTA: 84 ± 6 %, all p < 0.05). However, artificial lumen narrowing appeared similar in all imaging protocols (IRON (Gd/USPIO): 21 ± 3 %/21 ± 2 %; T1w: 16 ± 4 %/17 ± 3 %; CTA: 19 ± 2 %, all p = NS). Finally, IRON-MRA provided improvement of the in-stent lumen visualization with an ‘open-close-open’ design, which revealed a complete in-stent signal loss in T1w MRA. IRON-MRA improves in-stent visualization in vitro compared to conventional T1w MRA and CTA. In light of the in vitro results with Gd-enhanced IRON-MRA, the clinical implementation of such an approach appears promising. 
700 1 |a Fortner, Philipp  |e VerfasserIn  |0 (DE-588)1075389771  |0 (DE-627)833260456  |0 (DE-576)443459029  |4 aut 
700 1 |a Stuber, Matthias  |e VerfasserIn  |4 aut 
700 1 |a Missiou, Anna  |d 1978-  |e VerfasserIn  |0 (DE-588)134204441  |0 (DE-627)563001062  |0 (DE-576)276314514  |4 aut 
700 1 |a André, Florian  |d 1983-  |e VerfasserIn  |0 (DE-588)1051060230  |0 (DE-627)785671714  |0 (DE-576)405733267  |4 aut 
700 1 |a Müller, Oliver J.  |d 1971-  |e VerfasserIn  |0 (DE-588)121693449  |0 (DE-627)705619621  |0 (DE-576)292833504  |4 aut 
700 1 |a Katus, Hugo  |d 1951-  |e VerfasserIn  |0 (DE-588)108916618  |0 (DE-627)577155040  |0 (DE-576)289625076  |4 aut 
700 1 |a Korosoglou, Grigorios  |d 1976-  |e VerfasserIn  |0 (DE-588)12854225X  |0 (DE-627)374709025  |0 (DE-576)297204912  |4 aut 
773 0 8 |i Enthalten in  |t The international journal of cardiovascular imaging  |d Dordrecht [u.a.] : Springer, 2001  |g 32(2016), 11, Seite 1645-1655  |h Online-Ressource  |w (DE-627)320474321  |w (DE-600)2008950-8  |w (DE-576)121190994  |x 1875-8312  |7 nnas  |a Off-resonance magnetic resonance angiography improves visualization of in-stent lumen in peripheral nitinol stents compared to conventional T1-weighted acquisitions an in vitro comparison study 
773 1 8 |g volume:32  |g year:2016  |g number:11  |g pages:1645-1655  |g extent:11  |a Off-resonance magnetic resonance angiography improves visualization of in-stent lumen in peripheral nitinol stents compared to conventional T1-weighted acquisitions an in vitro comparison study 
856 4 0 |u https://doi.org/10.1007/s10554-016-0955-4  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200612 
993 |a Article 
994 |a 2016 
998 |g 12854225X  |a Korosoglou, Grigorios  |m 12854225X:Korosoglou, Grigorios  |d 50000  |e 50000PK12854225X  |k 0/50000/  |p 8  |y j 
998 |g 108916618  |a Katus, Hugo  |m 108916618:Katus, Hugo  |d 910000  |d 910100  |e 910000PK108916618  |e 910100PK108916618  |k 0/910000/  |k 1/910000/910100/  |p 7 
998 |g 121693449  |a Müller, Oliver J.  |m 121693449:Müller, Oliver J.  |d 910000  |d 910100  |d 50000  |e 910000PM121693449  |e 910100PM121693449  |e 50000PM121693449  |k 0/910000/  |k 1/910000/910100/  |k 0/50000/  |p 6 
998 |g 1051060230  |a André, Florian  |m 1051060230:André, Florian  |d 910000  |d 910100  |e 910000PA1051060230  |e 910100PA1051060230  |k 0/910000/  |k 1/910000/910100/  |p 5 
998 |g 134204441  |a Missiou, Anna  |m 134204441:Missiou, Anna  |d 910000  |d 910100  |e 910000PM134204441  |e 910100PM134204441  |k 0/910000/  |k 1/910000/910100/  |p 4 
998 |g 1075389771  |a Fortner, Philipp  |m 1075389771:Fortner, Philipp  |d 910000  |d 910100  |e 910000PF1075389771  |e 910100PF1075389771  |k 0/910000/  |k 1/910000/910100/  |p 2 
998 |g 138256209  |a Gitsioudis, Gitsios  |m 138256209:Gitsioudis, Gitsios  |d 910000  |d 910100  |e 910000PG138256209  |e 910100PG138256209  |k 0/910000/  |k 1/910000/910100/  |p 1  |x j 
999 |a KXP-PPN1700503545  |e 368662236X 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"roleDisplay":"VerfasserIn","family":"Gitsioudis","given":"Gitsios","role":"aut","display":"Gitsioudis, Gitsios"},{"roleDisplay":"VerfasserIn","family":"Fortner","given":"Philipp","role":"aut","display":"Fortner, Philipp"},{"roleDisplay":"VerfasserIn","family":"Stuber","display":"Stuber, Matthias","role":"aut","given":"Matthias"},{"family":"Missiou","roleDisplay":"VerfasserIn","given":"Anna","display":"Missiou, Anna","role":"aut"},{"given":"Florian","role":"aut","display":"André, Florian","family":"André","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","family":"Müller","role":"aut","display":"Müller, Oliver J.","given":"Oliver J."},{"given":"Hugo","role":"aut","display":"Katus, Hugo","roleDisplay":"VerfasserIn","family":"Katus"},{"roleDisplay":"VerfasserIn","family":"Korosoglou","display":"Korosoglou, Grigorios","role":"aut","given":"Grigorios"}],"physDesc":[{"extent":"11 S."}],"name":{"displayForm":["Gitsios Gitsioudis, Philipp Fortner, Matthias Stuber, Anna Missiou, Florian Andre, Oliver J. Müller, Hugo A. Katus, Grigorios Korosoglou"]},"relHost":[{"part":{"pages":"1645-1655","extent":"11","year":"2016","issue":"11","volume":"32","text":"32(2016), 11, Seite 1645-1655"},"physDesc":[{"extent":"Online-Ressource"}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"origin":[{"dateIssuedDisp":"2001-","dateIssuedKey":"2001","publisherPlace":"Dordrecht [u.a.]","publisher":"Springer"}],"disp":"Off-resonance magnetic resonance angiography improves visualization of in-stent lumen in peripheral nitinol stents compared to conventional T1-weighted acquisitions an in vitro comparison studyThe international journal of cardiovascular imaging","note":["Fortsetzung der Druck-Ausgabe","Gesehen am 02.08.2023"],"id":{"eki":["320474321"],"zdb":["2008950-8"],"issn":["1875-8312"]},"title":[{"title_sort":"international journal of cardiovascular imaging","title":"The international journal of cardiovascular imaging","subtitle":"X-Ray imaging, echocardiography, nuclear cardiology and magnetic resonance"}],"pubHistory":["Volume 17, issue 1 (February 2001)-"],"recId":"320474321"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedKey":"2016","dateIssuedDisp":"17 August 2016"}],"language":["eng"],"recId":"1700503545","id":{"doi":["10.1007/s10554-016-0955-4"],"eki":["1700503545"]},"title":[{"title_sort":"Off-resonance magnetic resonance angiography improves visualization of in-stent lumen in peripheral nitinol stents compared to conventional T1-weighted acquisitions","title":"Off-resonance magnetic resonance angiography improves visualization of in-stent lumen in peripheral nitinol stents compared to conventional T1-weighted acquisitions","subtitle":"an in vitro comparison study"}],"note":["Gesehen am 12.06.2020"]} 
SRT |a GITSIOUDISOFFRESONAN1720