Real-time 4DMRI-based internal target volume definition for moving lung tumors

Purpose In photon radiotherapy, respiratory-induced target motion can be accounted for by internal target volumes (ITV) or mid-ventilation target volumes (midV) defined on the basis of four-dimensional computed tomography (4D-CT). Intrinsic limitations of these approaches can result in target volume...

Full description

Saved in:
Bibliographic Details
Main Authors: Rabe, Moritz (Author) , Thieke, Christian (Author) , Düsberg, Mathias (Author) , Neppl, Sebastian (Author) , Gerum, Sabine (Author) , Reiner, Michael (Author) , Nicolay, Nils (Author) , Schlemmer, Heinz-Peter (Author) , Debus, Jürgen (Author) , Dinkel, Julien (Author) , Landry, Guillaume (Author) , Parodi, Katia (Author) , Belka, Claus (Author) , Kurz, Christopher (Author) , Kamp, Florian (Author)
Format: Article (Journal)
Language:English
Published: 19 January 2020
In: Medical physics
Year: 2020, Volume: 47, Issue: 4, Pages: 1431-1442
ISSN:2473-4209
DOI:10.1002/mp.14023
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1002/mp.14023
Verlag, lizenzpflichtig, Volltext: https://aapm.onlinelibrary.wiley.com/doi/abs/10.1002/mp.14023
Get full text
Author Notes:Moritz Rabe, Christian Thieke, Mathias Düsberg, Sebastian Neppl, Sabine Gerum, Michael Reiner, Nils Henrik Nicolay, Heinz-Peter Schlemmer, Jürgen Debus, Julien Dinkel, Guillaume Landry, Katia Parodi, Claus Belka, Christopher Kurz, Florian Kamp

MARC

LEADER 00000caa a2200000 c 4500
001 1700628364
003 DE-627
005 20230426062151.0
007 cr uuu---uuuuu
008 200616s2020 xx |||||o 00| ||eng c
024 7 |a 10.1002/mp.14023  |2 doi 
035 |a (DE-627)1700628364 
035 |a (DE-599)KXP1700628364 
035 |a (OCoLC)1341339470 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Rabe, Moritz  |d 1992-  |e VerfasserIn  |0 (DE-588)1212042719  |0 (DE-627)1700629069  |4 aut 
245 1 0 |a Real-time 4DMRI-based internal target volume definition for moving lung tumors  |c Moritz Rabe, Christian Thieke, Mathias Düsberg, Sebastian Neppl, Sabine Gerum, Michael Reiner, Nils Henrik Nicolay, Heinz-Peter Schlemmer, Jürgen Debus, Julien Dinkel, Guillaume Landry, Katia Parodi, Claus Belka, Christopher Kurz, Florian Kamp 
264 1 |c 19 January 2020 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 16.06.2020 
520 |a Purpose In photon radiotherapy, respiratory-induced target motion can be accounted for by internal target volumes (ITV) or mid-ventilation target volumes (midV) defined on the basis of four-dimensional computed tomography (4D-CT). Intrinsic limitations of these approaches can result in target volumes that are not representative for the gross tumor volume (GTV) motion over the course of treatment. To address these limitations, we propose a novel patient-specific ITV definition method based on real-time 4D magnetic resonance imaging (rt-4DMRI). Methods Three lung cancer patients underwent weekly rt-4DMRI scans. A total of 24 datasets were included in this retrospective study. The GTV was contoured on breath-hold MR images and propagated to all rt-4DMRI images by deformable image registration. Different targets were created for the first (reference) imaging sessions: ITVs encompassing all GTV positions over the complete (ITV) or partial acquisition time (), ITVs including only voxels with a GTV probability-of-presence (POP) of at least 5% () or 10% (), and the mid-ventilation GTV position. Reference planning target volumes () were created by adding margins around the ITVs and midV target volumes. The geometrical overlap of the with from the six to eight subsequent imaging sessions on days n was quantified in terms of the Dice similarity coefficient (DSC), sensitivity [SE: ()/] and precision [PRE: ()/] as surrogates for target coverage and normal tissue sparing. Results Patient-specific analysis yielded a high variance of the overlap values of , when different periods within the reference imaging session were sampled. The mid-ventilation-based PTVs were smaller than the ITV-based PTVs. While the SE was high for patients with small breathing pattern variations, changes of the median breathing amplitudes in different imaging sessions led to inferior SE values for the mid-ventilation PTV for one patient. In contrast, and showed higher SE values with a higher robustness against interfractional changes, at the cost of larger target volumes. Conclusions The results indicate that rt-4DMRI could be valuable for the definition of target volumes based on the GTV POP to achieve a higher robustness against interfractional changes than feasible with today’s 4D-CT-based target definition concepts. 
650 4 |a 4DMRI 
650 4 |a interfractional changes 
650 4 |a ITV 
650 4 |a lung tumor 
650 4 |a mid-ventilation 
650 4 |a motion management 
700 1 |a Thieke, Christian  |d 1970-  |e VerfasserIn  |0 (DE-588)129347396  |0 (DE-627)394260066  |0 (DE-576)297612417  |4 aut 
700 1 |a Düsberg, Mathias  |e VerfasserIn  |4 aut 
700 1 |a Neppl, Sebastian  |e VerfasserIn  |4 aut 
700 1 |a Gerum, Sabine  |d 1979-  |e VerfasserIn  |0 (DE-588)1053573359  |0 (DE-627)790307286  |0 (DE-576)409521531  |4 aut 
700 1 |a Reiner, Michael  |e VerfasserIn  |0 (DE-588)1131665732  |0 (DE-627)886309832  |0 (DE-576)488370825  |4 aut 
700 1 |a Nicolay, Nils  |e VerfasserIn  |0 (DE-588)136200834  |0 (DE-627)694181277  |0 (DE-576)279367880  |4 aut 
700 1 |a Schlemmer, Heinz-Peter  |d 1961-  |e VerfasserIn  |0 (DE-588)1025559967  |0 (DE-627)722927142  |0 (DE-576)17334805X  |4 aut 
700 1 |a Debus, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1022671421  |0 (DE-627)717025780  |0 (DE-576)365774944  |4 aut 
700 1 |a Dinkel, Julien  |d 1978-  |e VerfasserIn  |0 (DE-588)140755632  |0 (DE-627)621592773  |0 (DE-576)320647374  |4 aut 
700 1 |a Landry, Guillaume  |e VerfasserIn  |4 aut 
700 1 |a Parodi, Katia  |d 1975-  |e VerfasserIn  |0 (DE-588)129736996  |0 (DE-627)707308917  |0 (DE-576)188641688  |4 aut 
700 1 |a Belka, Claus  |e VerfasserIn  |0 (DE-588)143654829  |0 (DE-627)65383604X  |0 (DE-576)176701877  |4 aut 
700 1 |a Kurz, Christopher  |d 1986-  |e VerfasserIn  |0 (DE-588)1059754401  |0 (DE-627)798803983  |0 (DE-576)415808766  |4 aut 
700 1 |a Kamp, Florian  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Medical physics  |d Hoboken, NJ : Wiley, 1974  |g 47(2020), 4, Seite 1431-1442  |h Online-Ressource  |w (DE-627)265784867  |w (DE-600)1466421-5  |w (DE-576)074891243  |x 2473-4209  |7 nnas  |a Real-time 4DMRI-based internal target volume definition for moving lung tumors 
773 1 8 |g volume:47  |g year:2020  |g number:4  |g pages:1431-1442  |g extent:12  |a Real-time 4DMRI-based internal target volume definition for moving lung tumors 
856 4 0 |u https://doi.org/10.1002/mp.14023  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://aapm.onlinelibrary.wiley.com/doi/abs/10.1002/mp.14023  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200616 
993 |a Article 
994 |a 2020 
998 |g 1022671421  |a Debus, Jürgen  |m 1022671421:Debus, Jürgen  |d 910000  |d 911400  |e 910000PD1022671421  |e 911400PD1022671421  |k 0/910000/  |k 1/910000/911400/  |p 9 
998 |g 1025559967  |a Schlemmer, Heinz-Peter  |m 1025559967:Schlemmer, Heinz-Peter  |d 50000  |e 50000PS1025559967  |k 0/50000/  |p 8 
999 |a KXP-PPN1700628364  |e 3687408205 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 16.06.2020"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title":"Real-time 4DMRI-based internal target volume definition for moving lung tumors","title_sort":"Real-time 4DMRI-based internal target volume definition for moving lung tumors"}],"relHost":[{"title":[{"title":"Medical physics","title_sort":"Medical physics"}],"note":["Gesehen am 01.08.2025"],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"origin":[{"dateIssuedDisp":"1974-","dateIssuedKey":"1974","publisherPlace":"Hoboken, NJ ; College Park, Md. ; New York, NY","publisher":"Wiley ; AAPM ; [Verlag nicht ermittelbar]"}],"disp":"Real-time 4DMRI-based internal target volume definition for moving lung tumorsMedical physics","recId":"265784867","physDesc":[{"extent":"Online-Ressource"}],"part":{"issue":"4","extent":"12","text":"47(2020), 4, Seite 1431-1442","pages":"1431-1442","volume":"47","year":"2020"},"id":{"zdb":["1466421-5"],"issn":["2473-4209","1522-8541"],"eki":["265784867"]},"titleAlt":[{"title":"Medical physics online"}],"pubHistory":["1.1974 -"],"name":{"displayForm":["American Association of Physicists in Medicine ; American Institute of Physics"]}}],"person":[{"display":"Rabe, Moritz","given":"Moritz","role":"aut","family":"Rabe"},{"display":"Thieke, Christian","family":"Thieke","given":"Christian","role":"aut"},{"display":"Düsberg, Mathias","family":"Düsberg","given":"Mathias","role":"aut"},{"display":"Neppl, Sebastian","role":"aut","given":"Sebastian","family":"Neppl"},{"family":"Gerum","given":"Sabine","role":"aut","display":"Gerum, Sabine"},{"family":"Reiner","role":"aut","given":"Michael","display":"Reiner, Michael"},{"display":"Nicolay, Nils","family":"Nicolay","role":"aut","given":"Nils"},{"family":"Schlemmer","given":"Heinz-Peter","role":"aut","display":"Schlemmer, Heinz-Peter"},{"display":"Debus, Jürgen","given":"Jürgen","role":"aut","family":"Debus"},{"given":"Julien","role":"aut","family":"Dinkel","display":"Dinkel, Julien"},{"display":"Landry, Guillaume","given":"Guillaume","role":"aut","family":"Landry"},{"display":"Parodi, Katia","family":"Parodi","given":"Katia","role":"aut"},{"role":"aut","given":"Claus","family":"Belka","display":"Belka, Claus"},{"family":"Kurz","given":"Christopher","role":"aut","display":"Kurz, Christopher"},{"family":"Kamp","given":"Florian","role":"aut","display":"Kamp, Florian"}],"origin":[{"dateIssuedDisp":"19 January 2020","dateIssuedKey":"2020"}],"physDesc":[{"extent":"12 S."}],"recId":"1700628364","id":{"eki":["1700628364"],"doi":["10.1002/mp.14023"]},"name":{"displayForm":["Moritz Rabe, Christian Thieke, Mathias Düsberg, Sebastian Neppl, Sabine Gerum, Michael Reiner, Nils Henrik Nicolay, Heinz-Peter Schlemmer, Jürgen Debus, Julien Dinkel, Guillaume Landry, Katia Parodi, Claus Belka, Christopher Kurz, Florian Kamp"]}} 
SRT |a RABEMORITZREALTIME4D1920