Poly-acrylic acid brushes and adsorbed proteins

<section class="abstract"><h2 class="abstractTitle text-title my-1" id="d635e2">Abstract</h2><p>Planar polyelectrolyte brushes are prepared by Langmuir-Schaefer - based grafting of perdeuterated (styrene)<sub>49</sub>-b-(acrylic - aci...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Reinhardt, Matthias (VerfasserIn) , Kreuzer, Martin (VerfasserIn) , Geue, Thomas (VerfasserIn) , Dahint, Reiner (VerfasserIn) , Ballauff, Matthias (VerfasserIn) , Steitz, Roland (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 02.04.2015
In: Zeitschrift für physikalische Chemie
Year: 2015, Jahrgang: 229, Heft: 7-8, Pages: 1119-1139
ISSN:2196-7156
DOI:10.1515/zpch-2014-0540
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1515/zpch-2014-0540
Verlag, lizenzpflichtig, Volltext: https://www.degruyterbrill.com/view/journals/zpch/229/7-8/article-p1119.xml
Volltext
Verfasserangaben:Matthias Reinhardt, Martin Kreuzer, Thomas Geue, Reiner Dahint, Matthias Ballauff, Roland Steitz
Beschreibung
Zusammenfassung:<section class="abstract"><h2 class="abstractTitle text-title my-1" id="d635e2">Abstract</h2><p>Planar polyelectrolyte brushes are prepared by Langmuir-Schaefer - based grafting of perdeuterated (styrene)<sub>49</sub>-b-(acrylic - acid)<sub>222</sub> block copolymer (dPS-b-PAA) to dPS pre-coated silicon - supports with grafting density <em>σ</em><sub>PAA</sub> from 0.07 to - 0.11 nm<sup><em>-</em>2</sup>. The structure of the solvent-swollen brushes, - i. e. the volume fraction profile of polymer segments, <em>ϕ</em><sub>PAA</sub>, as a function of altitude <em>z</em> from the grafting - plane into the liquid phase is extracted from neutron reflectivity - measurements. We find that for all cases investigated - <em>ϕ</em><sub>PAA</sub>(<em>z</em>) resembles a Gaussian profile. Although very - condensed, the PAA brushes can be loaded with bovine serum albumin - (BSA). The integral amount of adsorbed BSA scales linearly with - grafting density. We compare our <em>z</em>-resolved volume fraction profile - <em>ϕ</em><sub>BSA</sub>(<em>z</em>) of BSA on PAA brushes with existing literature - on that system. It is found that a cross-over takes place in the - adsorption scheme from ternary compressive, where proteins can - approach the grafting surface only by compressing the brush, to - ternary insertive, where proteins enter the brush with only local - perturbation of the concentration profile, as a function of - <em>R</em><sub>P</sub>/<em>H</em><sub>max</sub>, where <em>R</em><sub>P</sub> is the - Stokes-Radius of the protein, and <em>H</em><sub>max</sub> is the - experimentally determined maximum height of - the brush.</p></section>
Beschreibung:Gesehen am 17.06.2020
Beschreibung:Online Resource
ISSN:2196-7156
DOI:10.1515/zpch-2014-0540