Flow-Induced Axial Vascularization: The Arteriovenous Loop in Angiogenesis and Tissue Engineering

Summary: - Fabrication of a viable vascular network providing oxygen supply is identified as one crucial limiting factor to generate more complex three-dimensional constructs. The arteriovenous loop model provides initial blood supply and has a high angioinductive potency, making it suitabl...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Leibig, Nico (VerfasserIn) , Wietbrock, Johanna O. (VerfasserIn) , Bigdeli, Amir Khosrow (VerfasserIn) , Horch, Raymund E. (VerfasserIn) , Kremer, Thomas (VerfasserIn) , Kneser, Ulrich (VerfasserIn) , Schmidt, Volker-Jürgen (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: May 13, 2016
In: Plastic and reconstructive surgery
Year: 2016, Jahrgang: 138, Heft: 4, Pages: 825-835
ISSN:1529-4242
DOI:10.1097/PRS.0000000000002554
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1097/PRS.0000000000002554
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/plasreconsurg/Fulltext/2016/10000/Flow_Induced_Axial_Vascularization__The.20.aspx
Volltext
Verfasserangaben:Nico Leibig, Johanna O. Wietbrock, Amir K. Bigdeli, Raymund E. Horch, Thomas Kremer, Ulrich Kneser, Volker J. Schmidt

MARC

LEADER 00000caa a2200000 c 4500
001 1701075555
003 DE-627
005 20240406193214.0
007 cr uuu---uuuuu
008 200618s2016 xx |||||o 00| ||eng c
024 7 |a 10.1097/PRS.0000000000002554  |2 doi 
035 |a (DE-627)1701075555 
035 |a (DE-599)KXP1701075555 
035 |a (OCoLC)1341340650 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Leibig, Nico  |d 1984-  |e VerfasserIn  |0 (DE-588)102478293X  |0 (DE-627)720537177  |0 (DE-576)369486803  |4 aut 
245 1 0 |a Flow-Induced Axial Vascularization  |b The Arteriovenous Loop in Angiogenesis and Tissue Engineering  |c Nico Leibig, Johanna O. Wietbrock, Amir K. Bigdeli, Raymund E. Horch, Thomas Kremer, Ulrich Kneser, Volker J. Schmidt 
264 1 |c May 13, 2016 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 18.06.2020 
520 |a Summary: - Fabrication of a viable vascular network providing oxygen supply is identified as one crucial limiting factor to generate more complex three-dimensional constructs. The arteriovenous loop model provides initial blood supply and has a high angioinductive potency, making it suitable for vascularization of larger, tissue-engineered constructs. Also because of its angiogenic capabilities the arteriovenous loop is recently also used as a model to evaluate angiogenesis in vivo. This review summarizes the history of the arteriovenous loop model in research and its technical and surgical aspects. Through modifications of the isolation chamber and its containing matrices, tissue generation can be enhanced. In addition, matrices can be used as release systems for local application of growth factors, such as vascular endothelial growth factor and basic fibroblast growth factor, to affect vascular network formation. A special focus in this review is set on the assessment of angiogenesis in the arteriovenous loop model. This model provides good conditions for assessment of angiogenesis with the initial cell-free environment of the isolation chamber, which is vascularized by the arteriovenous loop. Because of the angiogenic capabilities of the arteriovenous loop model, different attempts were performed to create functional tissue in the isolation chamber for potential clinical application. Arteriovenous loops in combination with autologous bone marrow aspirate were already used to reconstruct large bone defects in humans. 
700 1 |a Wietbrock, Johanna O.  |e VerfasserIn  |4 aut 
700 1 |a Bigdeli, Amir Khosrow  |d 1980-  |e VerfasserIn  |0 (DE-588)141636246  |0 (DE-627)630399433  |0 (DE-576)325071306  |4 aut 
700 1 |a Horch, Raymund E.  |e VerfasserIn  |4 aut 
700 1 |a Kremer, Thomas  |d 1975-  |e VerfasserIn  |0 (DE-588)128711310  |0 (DE-627)37830853X  |0 (DE-576)297293133  |4 aut 
700 1 |a Kneser, Ulrich  |d 1972-  |e VerfasserIn  |0 (DE-588)123065119  |0 (DE-627)706147219  |0 (DE-576)293539987  |4 aut 
700 1 |a Schmidt, Volker-Jürgen  |d 1979-  |e VerfasserIn  |0 (DE-588)137709870  |0 (DE-627)594853923  |0 (DE-576)304854921  |4 aut 
773 0 8 |i Enthalten in  |t Plastic and reconstructive surgery  |d Philadelphia, Pa. : Lippincott Williams & Wilkins, 1962  |g 138(2016), 4, Seite 825-835  |h Online-Ressource  |w (DE-627)325567743  |w (DE-600)2037030-1  |w (DE-576)094083398  |x 1529-4242  |7 nnas  |a Flow-Induced Axial Vascularization The Arteriovenous Loop in Angiogenesis and Tissue Engineering 
773 1 8 |g volume:138  |g year:2016  |g number:4  |g pages:825-835  |g extent:11  |a Flow-Induced Axial Vascularization The Arteriovenous Loop in Angiogenesis and Tissue Engineering 
856 4 0 |u https://doi.org/10.1097/PRS.0000000000002554  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.lww.com/plasreconsurg/Fulltext/2016/10000/Flow_Induced_Axial_Vascularization__The.20.aspx  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200618 
993 |a Article 
994 |a 2016 
998 |g 137709870  |a Schmidt, Volker-Jürgen  |m 137709870:Schmidt, Volker-Jürgen  |p 7  |y j 
998 |g 123065119  |a Kneser, Ulrich  |m 123065119:Kneser, Ulrich  |d 50000  |e 50000PK123065119  |k 0/50000/  |p 6 
998 |g 128711310  |a Kremer, Thomas  |m 128711310:Kremer, Thomas  |d 50000  |e 50000PK128711310  |k 0/50000/  |p 5 
998 |g 141636246  |a Bigdeli, Amir Khosrow  |m 141636246:Bigdeli, Amir Khosrow  |p 3 
999 |a KXP-PPN1701075555  |e 3688381106 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 18.06.2020"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedDisp":"May 13, 2016","dateIssuedKey":"2016"}],"physDesc":[{"extent":"11 S."}],"relHost":[{"recId":"325567743","titleAlt":[{"title":"PRS"}],"id":{"eki":["325567743"],"issn":["1529-4242"],"zdb":["2037030-1"]},"disp":"Flow-Induced Axial Vascularization The Arteriovenous Loop in Angiogenesis and Tissue EngineeringPlastic and reconstructive surgery","language":["eng"],"title":[{"title_sort":"Plastic and reconstructive surgery","title":"Plastic and reconstructive surgery","subtitle":"journal of the American Society of Plastic Surgeons ; official organ of the American Association of Plastic Surgeons ; official organ of the American Society of Aesthetic Plastic Surgery ; official organ of the American Society of Maxillofacial Surgeons ; official organ of the Plastic Surgery Research Council"}],"part":{"pages":"825-835","issue":"4","extent":"11","text":"138(2016), 4, Seite 825-835","volume":"138","year":"2016"},"note":["Gesehen am 21.08.25"],"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["29.1962 -"],"origin":[{"publisher":"Lippincott Williams & Wilkins","publisherPlace":"Philadelphia, Pa.","dateIssuedKey":"1962","dateIssuedDisp":"1962-"}],"physDesc":[{"extent":"Online-Ressource"}],"corporate":[{"role":"isb","display":"American Society of Plastic Surgeons","roleDisplay":"Herausgebendes Organ"},{"roleDisplay":"Herausgebendes Organ","display":"American Association of Plastic Surgeons","role":"isb"},{"display":"American Society for Aesthetic Plastic Surgery","roleDisplay":"Herausgebendes Organ","role":"isb"},{"role":"isb","display":"American Society of Maxillofacial Surgeons","roleDisplay":"Herausgebendes Organ"},{"roleDisplay":"Herausgebendes Organ","display":"Plastic Surgery Research Council","role":"isb"}]}],"title":[{"title":"Flow-Induced Axial Vascularization","subtitle":"The Arteriovenous Loop in Angiogenesis and Tissue Engineering","title_sort":"Flow-Induced Axial Vascularization"}],"name":{"displayForm":["Nico Leibig, Johanna O. Wietbrock, Amir K. Bigdeli, Raymund E. Horch, Thomas Kremer, Ulrich Kneser, Volker J. Schmidt"]},"person":[{"given":"Nico","roleDisplay":"VerfasserIn","display":"Leibig, Nico","family":"Leibig","role":"aut"},{"display":"Wietbrock, Johanna O.","roleDisplay":"VerfasserIn","given":"Johanna O.","role":"aut","family":"Wietbrock"},{"display":"Bigdeli, Amir Khosrow","roleDisplay":"VerfasserIn","given":"Amir Khosrow","role":"aut","family":"Bigdeli"},{"display":"Horch, Raymund E.","given":"Raymund E.","roleDisplay":"VerfasserIn","role":"aut","family":"Horch"},{"role":"aut","family":"Kremer","display":"Kremer, Thomas","given":"Thomas","roleDisplay":"VerfasserIn"},{"role":"aut","family":"Kneser","display":"Kneser, Ulrich","given":"Ulrich","roleDisplay":"VerfasserIn"},{"family":"Schmidt","role":"aut","roleDisplay":"VerfasserIn","given":"Volker-Jürgen","display":"Schmidt, Volker-Jürgen"}],"recId":"1701075555","language":["eng"],"id":{"eki":["1701075555"],"doi":["10.1097/PRS.0000000000002554"]}} 
SRT |a LEIBIGNICOFLOWINDUCE1320