High yield of bronchoscopic transparenchymal nodule access real-time image-guided sampling in a novel model of small pulmonary nodules in canines

BACKGROUND - Bronchoscopic transparenchymal nodule access (BTPNA) is a novel approach to accessing pulmonary nodules. This real-time, image-guided approach was evaluated for safety, accuracy, and yield in the healthy canine model. - METHODS - A novel, inorganic model of subcentimeter pulmonary nodul...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Sterman, Daniel H. (VerfasserIn) , Keast, Thomas (VerfasserIn) , Rai, Lav (VerfasserIn) , Gibbs, Jason (VerfasserIn) , Wibowo, Henky (VerfasserIn) , Draper, Jeff (VerfasserIn) , Herth, Felix (VerfasserIn) , Silvestri, Gerard A. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2015
In: Chest
Year: 2014, Jahrgang: 147, Heft: 3, Pages: 700-707
ISSN:1931-3543
DOI:10.1378/chest.14-0724
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1378/chest.14-0724
Verlag, lizenzpflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S0012369215396677
Volltext
Verfasserangaben:Daniel H. Sterman, MD, FCCP; Thomas Keast, BSME; Lav Rai, PhD; Jason Gibbs, PhD; Henky Wibowo, MSECE; Jeff Draper, MS; Felix J. Herth, MD, FCCP; and Gerard A. Silvestri, MD, FCC

MARC

LEADER 00000caa a2200000 c 4500
001 1701931591
003 DE-627
005 20220818130604.0
007 cr uuu---uuuuu
008 200623r20152014xx |||||o 00| ||eng c
024 7 |a 10.1378/chest.14-0724  |2 doi 
035 |a (DE-627)1701931591 
035 |a (DE-599)KXP1701931591 
035 |a (OCoLC)1341340964 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Sterman, Daniel H.  |e VerfasserIn  |0 (DE-588)1212447247  |0 (DE-627)1701932121  |4 aut 
245 1 0 |a High yield of bronchoscopic transparenchymal nodule access real-time image-guided sampling in a novel model of small pulmonary nodules in canines  |c Daniel H. Sterman, MD, FCCP; Thomas Keast, BSME; Lav Rai, PhD; Jason Gibbs, PhD; Henky Wibowo, MSECE; Jeff Draper, MS; Felix J. Herth, MD, FCCP; and Gerard A. Silvestri, MD, FCC 
264 1 |c 2015 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a originally published Online First October 2, 2014 
500 |a Gesehen am 23.06.2020 
520 |a BACKGROUND - Bronchoscopic transparenchymal nodule access (BTPNA) is a novel approach to accessing pulmonary nodules. This real-time, image-guided approach was evaluated for safety, accuracy, and yield in the healthy canine model. - METHODS - A novel, inorganic model of subcentimeter pulmonary nodules was developed, consisting of 0.25-cc aliquots of calcium hydroxylapatite (Radiesse) implanted via transbronchial access in airways seven generations beyond the main bronchi to represent targets for evaluation of accuracy and yield. Thoracic CT scans were acquired for each subject, and from these CT scans LungPoint Virtual Bronchoscopic Navigation software provided guidance to the region of interest. Novel transparenchymal nodule access software algorithms automatically generated point-of-entry recommendations, registered CT images, and real-time fluoroscopic images and overlaid guidance onto live bronchoscopic and fluoroscopic video to achieve a vessel-free, straight-line path from a central airway through parenchymal tissue for access to peripheral lesions. - RESULTS - In a nine-canine cohort, the BTPNA procedure was performed to sample 31 implanted Radiesse targets, implanted to simulate pulmonary nodules, via biopsy forceps through a specially designed sheath. The mean length of the 31 tunnels was 35 mm (20.5-50.3-mm range). Mean tunnel creation time was 16:52 min, and diagnostic yield was 90.3% (28 of 31). No significant adverse events were noted in the status of any of the canine subjects post BTPNA, with no pneumothoraces and minimal bleeding (all bleeding events < 2 mL in volume). - CONCLUSIONS - These canine studies demonstrate that BTPNA has the potential to achieve the high yield of transthoracic needle aspiration with the low complication profile associated with traditional bronchoscopy. These results merit further study in humans. 
534 |c 2014 
700 1 |a Keast, Thomas  |e VerfasserIn  |4 aut 
700 1 |a Rai, Lav  |e VerfasserIn  |4 aut 
700 1 |a Gibbs, Jason  |e VerfasserIn  |4 aut 
700 1 |a Wibowo, Henky  |e VerfasserIn  |4 aut 
700 1 |a Draper, Jeff  |e VerfasserIn  |4 aut 
700 1 |a Herth, Felix  |e VerfasserIn  |0 (DE-588)1016095236  |0 (DE-627)705477568  |0 (DE-576)351509925  |4 aut 
700 1 |a Silvestri, Gerard A.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Chest  |d Amsterdam : Elsevier, 1935  |g 147(2015), 3, Seite 700-707  |h Online-Ressource  |w (DE-627)320460819  |w (DE-600)2007244-2  |w (DE-576)09089202X  |x 1931-3543  |7 nnas  |a High yield of bronchoscopic transparenchymal nodule access real-time image-guided sampling in a novel model of small pulmonary nodules in canines 
773 1 8 |g volume:147  |g year:2015  |g number:3  |g pages:700-707  |g extent:8  |a High yield of bronchoscopic transparenchymal nodule access real-time image-guided sampling in a novel model of small pulmonary nodules in canines 
856 4 0 |u https://doi.org/10.1378/chest.14-0724  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0012369215396677  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200623 
993 |a Article 
994 |a 2015 
998 |g 1016095236  |a Herth, Felix  |m 1016095236:Herth, Felix  |d 910000  |d 950000  |d 950900  |d 50000  |e 910000PH1016095236  |e 950000PH1016095236  |e 950900PH1016095236  |e 50000PH1016095236  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |k 0/50000/  |p 7 
999 |a KXP-PPN1701931591  |e 369037166X 
BIB |a Y 
SER |a journal 
JSO |a {"note":["originally published Online First October 2, 2014","Gesehen am 23.06.2020"],"person":[{"given":"Daniel H.","display":"Sterman, Daniel H.","role":"aut","family":"Sterman"},{"display":"Keast, Thomas","given":"Thomas","role":"aut","family":"Keast"},{"role":"aut","family":"Rai","given":"Lav","display":"Rai, Lav"},{"display":"Gibbs, Jason","given":"Jason","family":"Gibbs","role":"aut"},{"display":"Wibowo, Henky","given":"Henky","role":"aut","family":"Wibowo"},{"family":"Draper","role":"aut","given":"Jeff","display":"Draper, Jeff"},{"display":"Herth, Felix","given":"Felix","family":"Herth","role":"aut"},{"family":"Silvestri","role":"aut","given":"Gerard A.","display":"Silvestri, Gerard A."}],"recId":"1701931591","language":["eng"],"name":{"displayForm":["Daniel H. Sterman, MD, FCCP; Thomas Keast, BSME; Lav Rai, PhD; Jason Gibbs, PhD; Henky Wibowo, MSECE; Jeff Draper, MS; Felix J. Herth, MD, FCCP; and Gerard A. Silvestri, MD, FCC"]},"origin":[{"dateIssuedKey":"2015","dateIssuedDisp":"2015"}],"relHost":[{"disp":"High yield of bronchoscopic transparenchymal nodule access real-time image-guided sampling in a novel model of small pulmonary nodules in caninesChest","type":{"bibl":"periodical","media":"Online-Ressource"},"corporate":[{"display":"American College of Chest Physicians","role":"isb"}],"titleAlt":[{"title":"Diseases of the chest"},{"title":"for pulmonologists, cardiologists, cardiothoracic surgeons, critical care physicians, and related specialists"},{"title":"the cardiopulmonary and critical care journal"},{"title":"for pulmonologists, cardiologists, cardiothoracic surgeons, critical care physicians, and related specialists"}],"language":["eng"],"part":{"text":"147(2015), 3, Seite 700-707","issue":"3","pages":"700-707","extent":"8","year":"2015","volume":"147"},"pubHistory":["1.1935 -"],"note":["Gesehen am 09.11.2017"],"title":[{"subtitle":"official publication of the American College of Chest Physicians ; for specialists in pulmonology, critical care, sleep medicine, thoracic surgery, cardiorespiratory interactions and related disciplines","title":"Chest","title_sort":"Chest"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["320460819"],"issn":["1931-3543"],"zdb":["2007244-2"]},"origin":[{"dateIssuedDisp":"1935-","publisher":"Elsevier ; American College of Chest Physicians","publisherPlace":"Amsterdam ; Northbrook, Ill. [u.a.]","dateIssuedKey":"1935"}],"recId":"320460819"}],"id":{"eki":["1701931591"],"doi":["10.1378/chest.14-0724"]},"physDesc":[{"extent":"8 S."}],"title":[{"title":"High yield of bronchoscopic transparenchymal nodule access real-time image-guided sampling in a novel model of small pulmonary nodules in canines","title_sort":"High yield of bronchoscopic transparenchymal nodule access real-time image-guided sampling in a novel model of small pulmonary nodules in canines"}],"type":{"media":"Online-Ressource","bibl":"article-journal"}} 
SRT |a STERMANDANHIGHYIELDO2015