A multicenter, open-label, controlled trial on acceptance, convenience, and complications of rechargeable internal pulse generators for deep brain stimulation: the multi recharge trial

Objective: Rechargeable neurostimulators for deep brain stimulation have been available since 2008, promising longer battery life and fewer replacement surgeries compared to non-rechargeable systems. Long-term data on how recharging affects movement disorder patients are sparse. This is the first mu...

Full description

Saved in:
Bibliographic Details
Main Authors: Jakobs, Martin (Author) , Helmers, Ann-Kristin (Author) , Synowitz, Michael (Author) , Slotty, Philipp J. (Author) , Anthofer, Judith M. (Author) , Schlaier, Jürgen R. (Author) , Kloss, Manja (Author) , Unterberg, Andreas (Author) , Kiening, Karl (Author)
Format: Article (Journal)
Language:English
Published: 2020
In: Journal of neurosurgery
Year: 2019, Volume: 133, Issue: 3, Pages: 821-829
ISSN:1933-0693
DOI:10.3171/2019.5.JNS19360
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.3171/2019.5.JNS19360
Verlag, lizenzpflichtig, Volltext: https://thejns.org/view/journals/j-neurosurg/aop/article-10.3171-2019.5.JNS19360/article-10.3171-2019.5.JNS19360.xml
Get full text
Author Notes:Martin Jakobs, Ann-Kristin Helmers, Michael Synowitz, Philipp J. Slotty, Judith M. Anthofer, Jürgen R. Schlaier, Manja Kloss, Andreas W. Unterberg, and Karl L. Kiening

MARC

LEADER 00000caa a2200000 c 4500
001 1701980827
003 DE-627
005 20220818131220.0
007 cr uuu---uuuuu
008 200623r20202019xx |||||o 00| ||eng c
024 7 |a 10.3171/2019.5.JNS19360  |2 doi 
035 |a (DE-627)1701980827 
035 |a (DE-599)KXP1701980827 
035 |a (OCoLC)1341341657 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Jakobs, Martin  |d 1985-  |e VerfasserIn  |0 (DE-588)1050384962  |0 (DE-627)78392092X  |0 (DE-576)404578756  |4 aut 
245 1 2 |a A multicenter, open-label, controlled trial on acceptance, convenience, and complications of rechargeable internal pulse generators for deep brain stimulation  |b the multi recharge trial  |c Martin Jakobs, Ann-Kristin Helmers, Michael Synowitz, Philipp J. Slotty, Judith M. Anthofer, Jürgen R. Schlaier, Manja Kloss, Andreas W. Unterberg, and Karl L. Kiening 
264 1 |c 2020 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published online August 16, 2019 
500 |a Gesehen am 06.05.2021 
520 |a Objective: Rechargeable neurostimulators for deep brain stimulation have been available since 2008, promising longer battery life and fewer replacement surgeries compared to non-rechargeable systems. Long-term data on how recharging affects movement disorder patients are sparse. This is the first multicenter, patient-focused, industry-independent study on rechargeable neurostimulators. Methods: Four neurosurgical centers sent a questionnaire to all adult movement disorder patients with a rechargeable neurostimulator implanted at the time of the trial. The primary endpoint was the convenience of the recharging process rated on an ordinal scale from “very hard” (1) to “very easy” (5). Secondary endpoints were charge burden (time spent per week on recharging), user confidence, and complication rates. Endpoints were compared for several subgroups. Results: Datasets of 195 movement disorder patients (66.1% of sent questionnaires) with Parkinson’s disease (PD), tremor, or dystonia were returned and included in the analysis. Patients had a mean age of 61.3 years and the device was implanted for a mean of 40.3 months. The overall convenience of recharging was rated as “easy” (4). The mean charge burden was 122 min/wk and showed a positive correlation with duration of therapy; 93.8% of users felt confident recharging the device. The rate of surgical revisions was 4.1%, and the infection rate was 2.1%. Failed recharges occurred in 8.7% of patients, and 3.6% of patients experienced an interruption of therapy because of a failed recharge. Convenience ratings by PD patients were significantly worse than ratings by dystonia patients. Caregivers recharged the device for the patient in 12.3% of cases. Patients who switched from a non-rechargeable to a rechargeable neurostimulator found recharging to be significantly less convenient at a higher charge burden than did patients whose primary implant was rechargeable. Age did not have a significant impact on any endpoint. Conclusions: Overall, patients with movement disorders rated recharging as easy, with low complication rates and acceptable charge burden. 
534 |c 2019 
700 1 |a Helmers, Ann-Kristin  |e VerfasserIn  |4 aut 
700 1 |a Synowitz, Michael  |e VerfasserIn  |4 aut 
700 1 |a Slotty, Philipp J.  |e VerfasserIn  |4 aut 
700 1 |a Anthofer, Judith M.  |e VerfasserIn  |4 aut 
700 1 |a Schlaier, Jürgen R.  |e VerfasserIn  |4 aut 
700 1 |a Kloss, Manja  |d 1972-  |e VerfasserIn  |0 (DE-588)136117945  |0 (DE-627)694095788  |0 (DE-576)300842112  |4 aut 
700 1 |a Unterberg, Andreas  |e VerfasserIn  |0 (DE-588)1032681187  |0 (DE-627)738641200  |0 (DE-576)168441233  |4 aut 
700 1 |a Kiening, Karl  |d 1959-  |e VerfasserIn  |0 (DE-588)128746262  |0 (DE-627)379124599  |0 (DE-576)297310917  |4 aut 
773 0 8 |i Enthalten in  |t Journal of neurosurgery  |d Charlottesville, Va. : American Assoc. of Neurological Surgeons, 1944  |g 133(2020), 3, Seite 821-829  |h Online-Ressource  |w (DE-627)323605737  |w (DE-600)2026156-1  |w (DE-576)09388866X  |x 1933-0693  |7 nnas  |a A multicenter, open-label, controlled trial on acceptance, convenience, and complications of rechargeable internal pulse generators for deep brain stimulation the multi recharge trial 
773 1 8 |g volume:133  |g year:2020  |g number:3  |g pages:821-829  |g extent:9  |a A multicenter, open-label, controlled trial on acceptance, convenience, and complications of rechargeable internal pulse generators for deep brain stimulation the multi recharge trial 
856 4 0 |u https://doi.org/10.3171/2019.5.JNS19360  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://thejns.org/view/journals/j-neurosurg/aop/article-10.3171-2019.5.JNS19360/article-10.3171-2019.5.JNS19360.xml  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200623 
993 |a Article 
994 |a 2020 
998 |g 128746262  |a Kiening, Karl  |m 128746262:Kiening, Karl  |d 910000  |d 911200  |e 910000PK128746262  |e 911200PK128746262  |k 0/910000/  |k 1/910000/911200/  |p 9  |y j 
998 |g 1032681187  |a Unterberg, Andreas  |m 1032681187:Unterberg, Andreas  |d 910000  |d 911200  |e 910000PU1032681187  |e 911200PU1032681187  |k 0/910000/  |k 1/910000/911200/  |p 8 
998 |g 136117945  |a Kloss, Manja  |m 136117945:Kloss, Manja  |p 7 
998 |g 1050384962  |a Jakobs, Martin  |m 1050384962:Jakobs, Martin  |d 910000  |d 911200  |e 910000PJ1050384962  |e 911200PJ1050384962  |k 0/910000/  |k 1/910000/911200/  |p 1  |x j 
999 |a KXP-PPN1701980827  |e 3690501202 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"physDesc":[{"extent":"9 S."}],"relHost":[{"note":["Gesehen am 04.08.25","Ungezählte Beil. 1999-2004,Jun : Spine; 2004-2007: Pediatrics"],"title":[{"subtitle":"JNS","title_sort":"Journal of neurosurgery","title":"Journal of neurosurgery"}],"pubHistory":["1.1944 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"origin":[{"publisherPlace":"Charlottesville, Va.","dateIssuedDisp":"1944-","publisher":"American Assoc. of Neurological Surgeons","dateIssuedKey":"1944"}],"titleAlt":[{"title":"Spine"},{"title":"Pediatrics"},{"title":"JNS"}],"disp":"A multicenter, open-label, controlled trial on acceptance, convenience, and complications of rechargeable internal pulse generators for deep brain stimulation the multi recharge trialJournal of neurosurgery","physDesc":[{"extent":"Online-Ressource"}],"corporate":[{"display":"American Association of Neurological Surgeons","role":"isb"}],"part":{"volume":"133","pages":"821-829","extent":"9","year":"2020","issue":"3","text":"133(2020), 3, Seite 821-829"},"language":["eng"],"id":{"eki":["323605737"],"zdb":["2026156-1"],"issn":["1933-0693"]},"recId":"323605737","name":{"displayForm":["American Association of Neurological Surgeons"]}}],"name":{"displayForm":["Martin Jakobs, Ann-Kristin Helmers, Michael Synowitz, Philipp J. Slotty, Judith M. Anthofer, Jürgen R. Schlaier, Manja Kloss, Andreas W. Unterberg, and Karl L. Kiening"]},"recId":"1701980827","id":{"doi":["10.3171/2019.5.JNS19360"],"eki":["1701980827"]},"note":["Published online August 16, 2019","Gesehen am 06.05.2021"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedDisp":"2020","dateIssuedKey":"2020"}],"person":[{"role":"aut","display":"Jakobs, Martin","family":"Jakobs","given":"Martin"},{"role":"aut","display":"Helmers, Ann-Kristin","family":"Helmers","given":"Ann-Kristin"},{"role":"aut","display":"Synowitz, Michael","family":"Synowitz","given":"Michael"},{"role":"aut","family":"Slotty","given":"Philipp J.","display":"Slotty, Philipp J."},{"display":"Anthofer, Judith M.","given":"Judith M.","family":"Anthofer","role":"aut"},{"family":"Schlaier","given":"Jürgen R.","display":"Schlaier, Jürgen R.","role":"aut"},{"display":"Kloss, Manja","given":"Manja","family":"Kloss","role":"aut"},{"family":"Unterberg","given":"Andreas","display":"Unterberg, Andreas","role":"aut"},{"role":"aut","given":"Karl","family":"Kiening","display":"Kiening, Karl"}],"title":[{"title":"A multicenter, open-label, controlled trial on acceptance, convenience, and complications of rechargeable internal pulse generators for deep brain stimulation","title_sort":"multicenter, open-label, controlled trial on acceptance, convenience, and complications of rechargeable internal pulse generators for deep brain stimulation","subtitle":"the multi recharge trial"}]} 
SRT |a JAKOBSMARTMULTICENTE2020