Toward standardized quantitative image quality (IQ) assessment in computed tomography (CT): a comprehensive framework for automated and comparative IQ analysis based on ICRU Report 87
Purpose - Based on the guidelines from “Report 87: Radiation Dose and Image-quality Assessment in Computed Tomography” of the International Commission on Radiation Units and Measurements (ICRU), a software framework for automated quantitative image quality analysis was developed and its usability fo...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2016
|
| In: |
Physica medica
Year: 2015, Jahrgang: 32, Heft: 1, Pages: 104-115 |
| ISSN: | 1724-191X |
| DOI: | 10.1016/j.ejmp.2015.09.017 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ejmp.2015.09.017 Verlag, lizenzpflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S1120179715010030 |
| Verfasserangaben: | Gregor Pahn, Stephan Skornitzke, Hans-Peter Schlemmer, Hans-Ulrich Kauczor, Wolfram Stiller |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1702839575 | ||
| 003 | DE-627 | ||
| 005 | 20230428073811.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200629r20162015xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.ejmp.2015.09.017 |2 doi | |
| 035 | |a (DE-627)1702839575 | ||
| 035 | |a (DE-599)KXP1702839575 | ||
| 035 | |a (OCoLC)1341341842 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Pahn, Gregor |e VerfasserIn |0 (DE-588)1120442567 |0 (DE-627)873380088 |0 (DE-576)480343551 |4 aut | |
| 245 | 1 | 0 | |a Toward standardized quantitative image quality (IQ) assessment in computed tomography (CT) |b a comprehensive framework for automated and comparative IQ analysis based on ICRU Report 87 |c Gregor Pahn, Stephan Skornitzke, Hans-Peter Schlemmer, Hans-Ulrich Kauczor, Wolfram Stiller |
| 264 | 1 | |c 2016 | |
| 300 | |a 12 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 28 October 2015 | ||
| 500 | |a Gesehen am 29.06.2020 | ||
| 520 | |a Purpose - Based on the guidelines from “Report 87: Radiation Dose and Image-quality Assessment in Computed Tomography” of the International Commission on Radiation Units and Measurements (ICRU), a software framework for automated quantitative image quality analysis was developed and its usability for a variety of scientific questions demonstrated. - Methods - The extendable framework currently implements the calculation of the recommended Fourier image quality (IQ) metrics modulation transfer function (MTF) and noise-power spectrum (NPS), and additional IQ quantities such as noise magnitude, CT number accuracy, uniformity across the field-of-view, contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of simulated lesions for a commercially available cone-beam phantom. Sample image data were acquired with different scan and reconstruction settings on CT systems from different manufacturers. - Results - Spatial resolution is analyzed in terms of edge-spread function, line-spread-function, and MTF. 3D NPS is calculated according to ICRU Report 87, and condensed to 2D and radially averaged 1D representations. Noise magnitude, CT numbers, and uniformity of these quantities are assessed on large samples of ROIs. Low-contrast resolution (CNR, SNR) is quantitatively evaluated as a function of lesion contrast and diameter. Simultaneous automated processing of several image datasets allows for straightforward comparative assessment. - Conclusions - The presented framework enables systematic, reproducible, automated and time-efficient quantitative IQ analysis. Consistent application of the ICRU guidelines facilitates standardization of quantitative assessment not only for routine quality assurance, but for a number of research questions, e.g. the comparison of different scanner models or acquisition protocols, and the evaluation of new technology or reconstruction methods. | ||
| 534 | |c 2015 | ||
| 650 | 4 | |a Computed tomography (CT) | |
| 650 | 4 | |a Modulation transfer function (MTF) | |
| 650 | 4 | |a Noise-power spectrum (NPS) | |
| 650 | 4 | |a Quantitative image quality assessment | |
| 700 | 1 | |a Skornitzke, Stephan |d 1987- |e VerfasserIn |0 (DE-588)1110072589 |0 (DE-627)864783523 |0 (DE-576)475718267 |4 aut | |
| 700 | 1 | |a Schlemmer, Heinz-Peter |d 1961- |e VerfasserIn |0 (DE-588)1025559967 |0 (DE-627)722927142 |0 (DE-576)17334805X |4 aut | |
| 700 | 1 | |a Kauczor, Hans-Ulrich |d 1962- |e VerfasserIn |0 (DE-588)139267123 |0 (DE-627)70327113X |0 (DE-576)310955327 |4 aut | |
| 700 | 1 | |a Stiller, Wolfram |d 1976- |e VerfasserIn |0 (DE-588)105822672X |0 (DE-627)796627495 |0 (DE-576)414249496 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Physica medica |d Amsterdam : Elsevier, 1996 |g 32(2016), 1, Seite 104-115 |h Online-Ressource |w (DE-627)364471417 |w (DE-600)2110535-2 |w (DE-576)272350176 |x 1724-191X |7 nnas |a Toward standardized quantitative image quality (IQ) assessment in computed tomography (CT) a comprehensive framework for automated and comparative IQ analysis based on ICRU Report 87 |
| 773 | 1 | 8 | |g volume:32 |g year:2016 |g number:1 |g pages:104-115 |g extent:12 |a Toward standardized quantitative image quality (IQ) assessment in computed tomography (CT) a comprehensive framework for automated and comparative IQ analysis based on ICRU Report 87 |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.ejmp.2015.09.017 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S1120179715010030 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200629 | ||
| 993 | |a Article | ||
| 994 | |a 2016 | ||
| 998 | |g 105822672X |a Stiller, Wolfram |m 105822672X:Stiller, Wolfram |d 910000 |d 911400 |e 910000PS105822672X |e 911400PS105822672X |k 0/910000/ |k 1/910000/911400/ |p 5 |y j | ||
| 998 | |g 139267123 |a Kauczor, Hans-Ulrich |m 139267123:Kauczor, Hans-Ulrich |d 910000 |d 911400 |e 910000PK139267123 |e 911400PK139267123 |k 0/910000/ |k 1/910000/911400/ |p 4 | ||
| 998 | |g 1025559967 |a Schlemmer, Heinz-Peter |m 1025559967:Schlemmer, Heinz-Peter |d 50000 |e 50000PS1025559967 |k 0/50000/ |p 3 | ||
| 998 | |g 1110072589 |a Skornitzke, Stephan |m 1110072589:Skornitzke, Stephan |d 910000 |d 911400 |e 910000PS1110072589 |e 911400PS1110072589 |k 0/910000/ |k 1/910000/911400/ |p 2 | ||
| 998 | |g 1120442567 |a Pahn, Gregor |m 1120442567:Pahn, Gregor |d 910000 |d 911400 |e 910000PP1120442567 |e 911400PP1120442567 |k 0/910000/ |k 1/910000/911400/ |p 1 |x j | ||
| 999 | |a KXP-PPN1702839575 |e 369204156X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"id":{"doi":["10.1016/j.ejmp.2015.09.017"],"eki":["1702839575"]},"name":{"displayForm":["Gregor Pahn, Stephan Skornitzke, Hans-Peter Schlemmer, Hans-Ulrich Kauczor, Wolfram Stiller"]},"recId":"1702839575","physDesc":[{"extent":"12 S."}],"title":[{"title":"Toward standardized quantitative image quality (IQ) assessment in computed tomography (CT)","title_sort":"Toward standardized quantitative image quality (IQ) assessment in computed tomography (CT)","subtitle":"a comprehensive framework for automated and comparative IQ analysis based on ICRU Report 87"}],"note":["Available online 28 October 2015","Gesehen am 29.06.2020"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"recId":"364471417","disp":"Toward standardized quantitative image quality (IQ) assessment in computed tomography (CT) a comprehensive framework for automated and comparative IQ analysis based on ICRU Report 87Physica medica","origin":[{"publisher":"Elsevier ; Istituti Editoriali e Poligrafici Internazionali","dateIssuedKey":"1996","publisherPlace":"Amsterdam ; Pisa","dateIssuedDisp":"1996-"}],"pubHistory":["Nachgewiesen 12.1996 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"note":["Fortsetzung der Druck-Ausgabe","Gesehen am 12.11.2021"],"id":{"issn":["1724-191X"],"eki":["364471417"],"zdb":["2110535-2"]},"part":{"year":"2016","volume":"32","pages":"104-115","issue":"1","extent":"12","text":"32(2016), 1, Seite 104-115"},"title":[{"subtitle":"European journal of medical physics ; an international journal devoted to the applications of physics to medicine and biology","title":"Physica medica","title_sort":"Physica medica"}]}],"person":[{"display":"Pahn, Gregor","family":"Pahn","given":"Gregor","role":"aut"},{"display":"Skornitzke, Stephan","given":"Stephan","role":"aut","family":"Skornitzke"},{"display":"Schlemmer, Heinz-Peter","given":"Heinz-Peter","role":"aut","family":"Schlemmer"},{"display":"Kauczor, Hans-Ulrich","given":"Hans-Ulrich","role":"aut","family":"Kauczor"},{"given":"Wolfram","role":"aut","family":"Stiller","display":"Stiller, Wolfram"}],"origin":[{"dateIssuedDisp":"2016","dateIssuedKey":"2016"}]} | ||
| SRT | |a PAHNGREGORTOWARDSTAN2016 | ||