Contrast of artificial subcutaneous hematomas in MRI over time

In clinical forensic medicine, hematomas and other externally visible injuries build the basis for the reconstruction of events. However, dating of subcutaneous hematomas based on their external aspect is difficult. Magnetic resonance imaging (MRI) has proven its use in dating intracranial hemorrhag...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hassler, Eva Maria (VerfasserIn) , Ogris, Kathrin (VerfasserIn) , Petrovic, Andreas (VerfasserIn) , Neumayer, Bernhard (VerfasserIn) , Widek, Thomas (VerfasserIn) , Yen, Kathrin (VerfasserIn) , Scheurer, Eva (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2015
In: International journal of legal medicine
Year: 2014, Jahrgang: 129, Heft: 2, Pages: 317-324
ISSN:1437-1596
DOI:10.1007/s00414-014-1124-8
Online-Zugang:Verlag, Volltext: https://doi.org/10.1007/s00414-014-1124-8
Volltext
Verfasserangaben:Eva Maria Hassler, Kathrin Ogris, Andreas Petrovic, Bernhard Neumayer, Thomas Widek, Kathrin Yen, Eva Scheurer

MARC

LEADER 00000caa a2200000 c 4500
001 1724641417
003 DE-627
005 20240930182749.0
007 cr uuu---uuuuu
008 200714r20152014xx |||||o 00| ||eng c
024 7 |a 10.1007/s00414-014-1124-8  |2 doi 
035 |a (DE-627)1724641417 
035 |a (DE-599)KXP1724641417 
035 |a (OCoLC)1341345101 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hassler, Eva Maria  |e VerfasserIn  |0 (DE-588)1213752345  |0 (DE-627)172464114X  |4 aut 
245 1 0 |a Contrast of artificial subcutaneous hematomas in MRI over time  |c Eva Maria Hassler, Kathrin Ogris, Andreas Petrovic, Bernhard Neumayer, Thomas Widek, Kathrin Yen, Eva Scheurer 
264 1 |c 2015 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published online: 23 November 2014 
500 |a Gesehen am 14.07.2020 
520 |a In clinical forensic medicine, hematomas and other externally visible injuries build the basis for the reconstruction of events. However, dating of subcutaneous hematomas based on their external aspect is difficult. Magnetic resonance imaging (MRI) has proven its use in dating intracranial hemorrhage. Thus, the aim was to investigate if MRI can also be used for dating subcutaneous hematomas and to analyze an eventual influence of the hematoma shape. In 20 healthy volunteers (11 females, 9 males, aged 26.9 ± 3.8 years), 4 ml of autologous blood were injected subcutaneously in the thigh. The hematoma was scanned immediately after the injection, after 3 and 24 h and 3, 7, and 14 days using three sequences with different contrast. Data was analyzed by measuring signal intensities of the hematoma, the muscle, and the subcutaneous tissue over time, and the Michelson contrast coefficients between the tissues were calculated. In the analysis, hematoma shape was considered. Signal intensity of blood in the proton density-weighted sequence reached its maximum 3 h after the injection with a subsequent decrease, whereas the signal intensities of muscle and fatty tissue remained constant. The time course of the Michelson coefficient of blood versus muscle decreased exponentially with a change from hyperintensity to hypointensity at 116.9 h, depending on hematoma shape. In the other sequences, either variability was large or contrast coefficients stayed constant over time. The observed change of contrast of blood versus muscle permits a quick estimate of a hematoma’s age. The consideration of the hematoma shape is expected to further enhance dating using MRI. 
534 |c 2014 
700 1 |a Ogris, Kathrin  |e VerfasserIn  |0 (DE-588)1166676021  |0 (DE-627)1030547173  |0 (DE-576)510845088  |4 aut 
700 1 |a Petrovic, Andreas  |e VerfasserIn  |4 aut 
700 1 |a Neumayer, Bernhard  |e VerfasserIn  |4 aut 
700 1 |a Widek, Thomas  |e VerfasserIn  |4 aut 
700 1 |a Yen, Kathrin  |e VerfasserIn  |0 (DE-588)106866066X  |0 (DE-627)82057869X  |0 (DE-576)427995957  |4 aut 
700 1 |a Scheurer, Eva  |e VerfasserIn  |0 (DE-588)1201126029  |0 (DE-627)1684410282  |4 aut 
773 0 8 |i Enthalten in  |t International journal of legal medicine  |d Berlin : Springer, 1990  |g 129(2015), 2, Seite 317-324  |h Online-Ressource  |w (DE-627)253724295  |w (DE-600)1459222-8  |w (DE-576)072373148  |x 1437-1596  |7 nnas  |a Contrast of artificial subcutaneous hematomas in MRI over time 
773 1 8 |g volume:129  |g year:2015  |g number:2  |g pages:317-324  |g extent:8  |a Contrast of artificial subcutaneous hematomas in MRI over time 
856 4 0 |u https://doi.org/10.1007/s00414-014-1124-8  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20200714 
993 |a Article 
994 |a 2015 
998 |g 106866066X  |a Yen, Kathrin  |m 106866066X:Yen, Kathrin  |d 910000  |d 912100  |e 910000PY106866066X  |e 912100PY106866066X  |k 0/910000/  |k 1/910000/912100/  |p 6 
999 |a KXP-PPN1724641417  |e 3724158289 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"part":{"volume":"129","pages":"317-324","year":"2015","text":"129(2015), 2, Seite 317-324","extent":"8","issue":"2"},"origin":[{"publisher":"Springer ; HeinOnline ; Springer","dateIssuedDisp":"1990-","publisherPlace":"Berlin ; Heidelberg ; Getzville, NY ; Berlin ; Heidelberg ; New York, NY","dateIssuedKey":"1990"}],"disp":"Contrast of artificial subcutaneous hematomas in MRI over timeInternational journal of legal medicine","pubHistory":["Volume 104, issue 1 (January 1990)-"],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 06.03.25","Volltext auch als Teil einer Datenbank verfügbar"],"title":[{"title_sort":"International journal of legal medicine","subtitle":"official publication of the International Academy of Legal Medicine","title":"International journal of legal medicine"}],"recId":"253724295","titleAlt":[{"title":"Legal medicine"}],"language":["eng","ger"],"id":{"eki":["253724295"],"issn":["1437-1596"],"zdb":["1459222-8"]},"physDesc":[{"extent":"Online-Ressource"}]}],"name":{"displayForm":["Eva Maria Hassler, Kathrin Ogris, Andreas Petrovic, Bernhard Neumayer, Thomas Widek, Kathrin Yen, Eva Scheurer"]},"origin":[{"dateIssuedKey":"2015","dateIssuedDisp":"2015"}],"title":[{"title":"Contrast of artificial subcutaneous hematomas in MRI over time","title_sort":"Contrast of artificial subcutaneous hematomas in MRI over time"}],"person":[{"role":"aut","given":"Eva Maria","roleDisplay":"VerfasserIn","family":"Hassler","display":"Hassler, Eva Maria"},{"role":"aut","given":"Kathrin","family":"Ogris","display":"Ogris, Kathrin","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","family":"Petrovic","display":"Petrovic, Andreas","given":"Andreas","role":"aut"},{"display":"Neumayer, Bernhard","family":"Neumayer","roleDisplay":"VerfasserIn","role":"aut","given":"Bernhard"},{"roleDisplay":"VerfasserIn","display":"Widek, Thomas","family":"Widek","given":"Thomas","role":"aut"},{"roleDisplay":"VerfasserIn","family":"Yen","display":"Yen, Kathrin","role":"aut","given":"Kathrin"},{"roleDisplay":"VerfasserIn","family":"Scheurer","display":"Scheurer, Eva","given":"Eva","role":"aut"}],"note":["Published online: 23 November 2014","Gesehen am 14.07.2020"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"physDesc":[{"extent":"8 S."}],"language":["eng"],"id":{"doi":["10.1007/s00414-014-1124-8"],"eki":["1724641417"]},"recId":"1724641417"} 
SRT |a HASSLEREVACONTRASTOF2015