Assessment of powder blend uniformity: comparison of real-time NIR blend monitoring with stratified sampling in combination with HPLC and at-line NIR Chemical Imaging
Scope of the study was (1) to develop a lean quantitative calibration for real-time near-infrared (NIR) blend monitoring, which meets the requirements in early development of pharmaceutical products and (2) to compare the prediction performance of this approach with the results obtained from stratif...
Gespeichert in:
| Hauptverfasser: | , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
9 October 2015
|
| In: |
European journal of pharmaceutics and biopharmaceutics
Year: 2015, Jahrgang: 97, Pages: 78-89 |
| ISSN: | 1873-3441 |
| DOI: | 10.1016/j.ejpb.2015.10.002 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ejpb.2015.10.002 Verlag, lizenzpflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S0939641115004038 |
| Verfasserangaben: | Barbara Bakri, Marco Weimer, Gerrit Hauck, Gabriele Reich |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 172583684X | ||
| 003 | DE-627 | ||
| 005 | 20230428072928.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200729s2015 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.ejpb.2015.10.002 |2 doi | |
| 035 | |a (DE-627)172583684X | ||
| 035 | |a (DE-599)KXP172583684X | ||
| 035 | |a (OCoLC)1341348597 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Bakri, Barbara |e VerfasserIn |0 (DE-588)107903028X |0 (DE-627)840092857 |0 (DE-576)452147786 |4 aut | |
| 245 | 1 | 0 | |a Assessment of powder blend uniformity |b comparison of real-time NIR blend monitoring with stratified sampling in combination with HPLC and at-line NIR Chemical Imaging |c Barbara Bakri, Marco Weimer, Gerrit Hauck, Gabriele Reich |
| 264 | 1 | |c 9 October 2015 | |
| 300 | |a 12 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 29.07.2020 | ||
| 520 | |a Scope of the study was (1) to develop a lean quantitative calibration for real-time near-infrared (NIR) blend monitoring, which meets the requirements in early development of pharmaceutical products and (2) to compare the prediction performance of this approach with the results obtained from stratified sampling using a sample thief in combination with off-line high pressure liquid chromatography (HPLC) and at-line near-infrared chemical imaging (NIRCI). Tablets were manufactured from powder blends and analyzed with NIRCI and HPLC to verify the real-time results. The model formulation contained 25% w/w naproxen as a cohesive active pharmaceutical ingredient (API), microcrystalline cellulose and croscarmellose sodium as cohesive excipients and free-flowing mannitol. Five in-line NIR calibration approaches, all using the spectra from the end of the blending process as reference for PLS modeling, were compared in terms of selectivity, precision, prediction accuracy and robustness. High selectivity could be achieved with a “reduced” approach i.e. API and time saving approach (35% reduction of API amount) based on six concentration levels of the API with three levels realized by three independent powder blends and the additional levels obtained by simply increasing the API concentration in these blends. Accuracy and robustness were further improved by combining this calibration set with a second independent data set comprising different excipient concentrations and reflecting different environmental conditions. The combined calibration model was used to monitor the blending process of independent batches. For this model formulation the target concentration of the API could be achieved within 3min indicating a short blending time. The in-line NIR approach was verified by stratified sampling HPLC and NIRCI results. All three methods revealed comparable results regarding blend end point determination. Differences in both mean API concentration and RSD values could be attributed to differences in effective sample size and thief sampling errors. This conclusion was supported by HPLC and NIRCI analysis of tablets manufactured from powder blends after different blending times. In summary, the study clearly demonstrates the ability to develop efficient and robust quantitative calibrations for real-time NIR powder blend monitoring with a reduced set of powder blends while avoiding any bias caused by physical sampling. | ||
| 650 | 4 | |a Blend monitoring | |
| 650 | 4 | |a Near-Infrared Spectroscopy (NIRS) | |
| 650 | 4 | |a NIR Chemical Imaging (NIRCI) | |
| 650 | 4 | |a Powder blend uniformity | |
| 650 | 4 | |a Process Analytical Technology (PAT) | |
| 650 | 4 | |a Stratified sampling | |
| 700 | 1 | |a Weimer, Marco |e VerfasserIn |4 aut | |
| 700 | 1 | |a Hauck, Gerrit |e VerfasserIn |4 aut | |
| 700 | 1 | |a Reich, Gabriele |d 1956- |e VerfasserIn |0 (DE-588)139508449 |0 (DE-627)703350765 |0 (DE-576)312103654 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t European journal of pharmaceutics and biopharmaceutics |d New York, NY [u.a.] : Elsevier, 1997 |g 97(2015), Seite 78-89 |h Online-Ressource |w (DE-627)300897324 |w (DE-600)1483524-1 |w (DE-576)259270822 |x 1873-3441 |7 nnas |a Assessment of powder blend uniformity comparison of real-time NIR blend monitoring with stratified sampling in combination with HPLC and at-line NIR Chemical Imaging |
| 773 | 1 | 8 | |g volume:97 |g year:2015 |g pages:78-89 |g extent:12 |a Assessment of powder blend uniformity comparison of real-time NIR blend monitoring with stratified sampling in combination with HPLC and at-line NIR Chemical Imaging |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.ejpb.2015.10.002 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S0939641115004038 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200729 | ||
| 993 | |a Article | ||
| 994 | |a 2015 | ||
| 998 | |g 139508449 |a Reich, Gabriele |m 139508449:Reich, Gabriele |d 160000 |d 160100 |e 160000PR139508449 |e 160100PR139508449 |k 0/160000/ |k 1/160000/160100/ |p 4 |y j | ||
| 998 | |g 107903028X |a Bakri, Barbara |m 107903028X:Bakri, Barbara |p 1 |x j | ||
| 999 | |a KXP-PPN172583684X |e 3731912228 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"recId":"172583684X","language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 29.07.2020"],"title":[{"subtitle":"comparison of real-time NIR blend monitoring with stratified sampling in combination with HPLC and at-line NIR Chemical Imaging","title":"Assessment of powder blend uniformity","title_sort":"Assessment of powder blend uniformity"}],"person":[{"role":"aut","display":"Bakri, Barbara","roleDisplay":"VerfasserIn","given":"Barbara","family":"Bakri"},{"roleDisplay":"VerfasserIn","display":"Weimer, Marco","role":"aut","family":"Weimer","given":"Marco"},{"family":"Hauck","given":"Gerrit","roleDisplay":"VerfasserIn","display":"Hauck, Gerrit","role":"aut"},{"family":"Reich","given":"Gabriele","roleDisplay":"VerfasserIn","display":"Reich, Gabriele","role":"aut"}],"relHost":[{"id":{"zdb":["1483524-1"],"eki":["300897324"],"issn":["1873-3441"]},"origin":[{"publisherPlace":"New York, NY [u.a.]","dateIssuedDisp":"1997-","publisher":"Elsevier","dateIssuedKey":"1997"}],"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"European journal of pharmaceutics and biopharmaceutics","subtitle":"EJPB ; official journal of the International Association for Pharmaceutical Technology","title":"European journal of pharmaceutics and biopharmaceutics"}],"titleAlt":[{"title":"EJPB"}],"part":{"volume":"97","text":"97(2015), Seite 78-89","extent":"12","year":"2015","pages":"78-89"},"pubHistory":["Nachgewiesen 43.1997 -"],"language":["eng"],"recId":"300897324","note":["Gesehen am 25.05.2020"],"disp":"Assessment of powder blend uniformity comparison of real-time NIR blend monitoring with stratified sampling in combination with HPLC and at-line NIR Chemical ImagingEuropean journal of pharmaceutics and biopharmaceutics","type":{"media":"Online-Ressource","bibl":"periodical"}}],"physDesc":[{"extent":"12 S."}],"id":{"doi":["10.1016/j.ejpb.2015.10.002"],"eki":["172583684X"]},"origin":[{"dateIssuedDisp":"9 October 2015","dateIssuedKey":"2015"}],"name":{"displayForm":["Barbara Bakri, Marco Weimer, Gerrit Hauck, Gabriele Reich"]}} | ||
| SRT | |a BAKRIBARBAASSESSMENT9201 | ||