Total aortic arch replacement: superior ventriculo-arterial coupling with decellularized allografts compared with conventional prostheses

Background: To date, no experimental or clinical study provides detailed analysis of vascular impedance changes after total aortic arch replacement. This study investigated ventriculoarterial coupling and vascular impedance after replacement of the aortic arch with conventional prostheses vs. decell...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Weymann, Alexander (VerfasserIn) , Schmack, Bastian (VerfasserIn) , Korkmaz-İçöz, Sevil (VerfasserIn) , Chaimow, Nicole (VerfasserIn) , Veres, Gábor (VerfasserIn) , Karck, Matthias (VerfasserIn) , Szabó, Gábor (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: July 31, 2014
In: PLOS ONE
Year: 2014, Jahrgang: 9, Heft: 7
ISSN:1932-6203
DOI:10.1371/journal.pone.0103588
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1371/journal.pone.0103588
Verlag, lizenzpflichtig, Volltext: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0103588
Volltext
Verfasserangaben:Alexander Weymann, Tamás Radovits, Bastian Schmack, Sevil Korkmaz, Shiliang Li, Nicole Chaimow, Ines Pätzold, Peter Moritz Becher, István Hartyánszky, Pál Soós, Gergő Merkely, Balázs Tamás Németh, Roland Istók, Gábor Veres, Béla Merkely, Konstantin Terytze, Matthias Karck, Gábor Szabó

MARC

LEADER 00000caa a2200000 c 4500
001 1725854783
003 DE-627
005 20220818163424.0
007 cr uuu---uuuuu
008 200729s2014 xx |||||o 00| ||eng c
024 7 |a 10.1371/journal.pone.0103588  |2 doi 
035 |a (DE-627)1725854783 
035 |a (DE-599)KXP1725854783 
035 |a (OCoLC)1341348859 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Weymann, Alexander  |e VerfasserIn  |0 (DE-588)1051122651  |0 (DE-627)785827102  |0 (DE-576)40592657X  |4 aut 
245 1 0 |a Total aortic arch replacement  |b superior ventriculo-arterial coupling with decellularized allografts compared with conventional prostheses  |c Alexander Weymann, Tamás Radovits, Bastian Schmack, Sevil Korkmaz, Shiliang Li, Nicole Chaimow, Ines Pätzold, Peter Moritz Becher, István Hartyánszky, Pál Soós, Gergő Merkely, Balázs Tamás Németh, Roland Istók, Gábor Veres, Béla Merkely, Konstantin Terytze, Matthias Karck, Gábor Szabó 
264 1 |c July 31, 2014 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 29.07.2020 
520 |a Background: To date, no experimental or clinical study provides detailed analysis of vascular impedance changes after total aortic arch replacement. This study investigated ventriculoarterial coupling and vascular impedance after replacement of the aortic arch with conventional prostheses vs. decellularized allografts. Methods: After preparing decellularized aortic arch allografts, their mechanical, histological and biochemical properties were evaluated and compared to native aortic arches and conventional prostheses in vitro. In open-chest dogs, total aortic arch replacement was performed with conventional prostheses and compared to decellularized allografts (n = 5/group). Aortic flow and pressure were recorded continuously, left ventricular pressure-volume relations were measured by using a pressure-conductance catheter. From the hemodynamic variables end-systolic elastance (Ees), arterial elastance (Ea) and ventriculoarterial coupling were calculated. Characteristic impedance (Z) was assessed by Fourier analysis. Results: While Ees did not differ between the groups and over time (4.1±1.19 vs. 4.58±1.39 mmHg/mL and 3.21±0.97 vs. 3.96±1.16 mmHg/mL), Ea showed a higher increase in the prosthesis group (4.01±0.67 vs. 6.18±0.20 mmHg/mL, P<0.05) in comparison to decellularized allografts (5.03±0.35 vs. 5.99±1.09 mmHg/mL). This led to impaired ventriculoarterial coupling in the prosthesis group, while it remained unchanged in the allograft group (62.5±50.9 vs. 3.9±23.4%). Z showed a strong increasing tendency in the prosthesis group and it was markedly higher after replacement when compared to decellularized allografts (44.6±8.3dyn·sec·cm−5 vs. 32.4±2.0dyn·sec·cm−5, P<0.05). Conclusions: Total aortic arch replacement leads to contractility-afterload mismatch by means of increased impedance and invert ventriculoarterial coupling ratio after implantation of conventional prostheses. Implantation of decellularized allografts preserves vascular impedance thereby improving ventriculoarterial mechanoenergetics after aortic arch replacement. 
650 4 |a Aorta 
650 4 |a Blood pressure 
650 4 |a Collagens 
650 4 |a Elastin 
650 4 |a Hemodynamics 
650 4 |a Medical implants 
650 4 |a Prosthetics 
650 4 |a Transmission electron microscopy 
700 1 |a Schmack, Bastian  |d 1981-  |e VerfasserIn  |0 (DE-588)142852961  |0 (DE-627)640546293  |0 (DE-576)333714067  |4 aut 
700 1 |a Korkmaz-İçöz, Sevil  |e VerfasserIn  |0 (DE-588)1062748697  |0 (DE-627)806830336  |0 (DE-576)420147845  |4 aut 
700 1 |a Chaimow, Nicole  |e VerfasserIn  |0 (DE-588)1107970415  |0 (DE-627)863713661  |0 (DE-576)475152212  |4 aut 
700 1 |a Veres, Gábor  |e VerfasserIn  |0 (DE-588)1080537139  |0 (DE-627)844782319  |0 (DE-576)453604927  |4 aut 
700 1 |a Karck, Matthias  |d 1961-  |e VerfasserIn  |0 (DE-588)130833525  |0 (DE-627)505909340  |0 (DE-576)298366169  |4 aut 
700 1 |a Szabó, Gábor  |d 1969-  |e VerfasserIn  |0 (DE-588)1022955152  |0 (DE-627)717338681  |0 (DE-576)366215485  |4 aut 
773 0 8 |i Enthalten in  |t PLOS ONE  |d San Francisco, California, US : PLOS, 2006  |g 9(2014,7) Artikel-Nummer e103588, 10 Seiten  |h Online-Ressource  |w (DE-627)523574592  |w (DE-600)2267670-3  |w (DE-576)281331979  |x 1932-6203  |7 nnas  |a Total aortic arch replacement superior ventriculo-arterial coupling with decellularized allografts compared with conventional prostheses 
773 1 8 |g volume:9  |g year:2014  |g number:7  |g extent:10  |a Total aortic arch replacement superior ventriculo-arterial coupling with decellularized allografts compared with conventional prostheses 
856 4 0 |u https://doi.org/10.1371/journal.pone.0103588  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0103588  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200729 
993 |a Article 
994 |a 2014 
998 |g 1022955152  |a Szabó, Gábor  |m 1022955152:Szabó, Gábor  |d 910000  |d 910200  |e 910000PS1022955152  |e 910200PS1022955152  |k 0/910000/  |k 1/910000/910200/  |p 18  |y j 
998 |g 130833525  |a Karck, Matthias  |m 130833525:Karck, Matthias  |d 910000  |d 910200  |e 910000PK130833525  |e 910200PK130833525  |k 0/910000/  |k 1/910000/910200/  |p 17 
998 |g 1080537139  |a Veres, Gábor  |m 1080537139:Veres, Gábor  |d 910000  |d 910200  |e 910000PV1080537139  |e 910200PV1080537139  |k 0/910000/  |k 1/910000/910200/  |p 14 
998 |g 1107970415  |a Chaimow, Nicole  |m 1107970415:Chaimow, Nicole  |d 910000  |d 910200  |e 910000PC1107970415  |e 910200PC1107970415  |k 0/910000/  |k 1/910000/910200/  |p 6 
998 |g 1062748697  |a Korkmaz-İçöz, Sevil  |m 1062748697:Korkmaz-İçöz, Sevil  |d 910000  |d 910200  |e 910000PK1062748697  |e 910200PK1062748697  |k 0/910000/  |k 1/910000/910200/  |p 4 
998 |g 142852961  |a Schmack, Bastian  |m 142852961:Schmack, Bastian  |d 910000  |d 910200  |e 910000PS142852961  |e 910200PS142852961  |k 0/910000/  |k 1/910000/910200/  |p 3 
998 |g 1051122651  |a Weymann, Alexander  |m 1051122651:Weymann, Alexander  |d 910000  |d 910200  |e 910000PW1051122651  |e 910200PW1051122651  |k 0/910000/  |k 1/910000/910200/  |p 1  |x j 
999 |a KXP-PPN1725854783  |e 3731955482 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1725854783"],"doi":["10.1371/journal.pone.0103588"]},"name":{"displayForm":["Alexander Weymann, Tamás Radovits, Bastian Schmack, Sevil Korkmaz, Shiliang Li, Nicole Chaimow, Ines Pätzold, Peter Moritz Becher, István Hartyánszky, Pál Soós, Gergő Merkely, Balázs Tamás Németh, Roland Istók, Gábor Veres, Béla Merkely, Konstantin Terytze, Matthias Karck, Gábor Szabó"]},"recId":"1725854783","physDesc":[{"extent":"10 S."}],"title":[{"subtitle":"superior ventriculo-arterial coupling with decellularized allografts compared with conventional prostheses","title":"Total aortic arch replacement","title_sort":"Total aortic arch replacement"}],"note":["Gesehen am 29.07.2020"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"relHost":[{"recId":"523574592","physDesc":[{"extent":"Online-Ressource"}],"disp":"Total aortic arch replacement superior ventriculo-arterial coupling with decellularized allografts compared with conventional prosthesesPLOS ONE","origin":[{"publisherPlace":"San Francisco, California, US ; Lawrence, Kan.","dateIssuedKey":"2006","dateIssuedDisp":"2006-","publisher":"PLOS ; PLoS"}],"title":[{"title_sort":"PLOS ONE","title":"PLOS ONE"}],"note":["Schreibweise des Titels bis 2012: PLoS ONE","Gesehen am 20.03.19"],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"pubHistory":["1.2006 -"],"name":{"displayForm":["Public Library of Science"]},"corporate":[{"role":"isb","display":"Public Library of Science"}],"part":{"year":"2014","issue":"7","volume":"9","text":"9(2014,7) Artikel-Nummer e103588, 10 Seiten","extent":"10"},"id":{"eki":["523574592"],"issn":["1932-6203"],"zdb":["2267670-3"]}}],"person":[{"display":"Weymann, Alexander","role":"aut","given":"Alexander","family":"Weymann"},{"display":"Schmack, Bastian","family":"Schmack","given":"Bastian","role":"aut"},{"display":"Korkmaz-İçöz, Sevil","family":"Korkmaz-İçöz","given":"Sevil","role":"aut"},{"display":"Chaimow, Nicole","family":"Chaimow","given":"Nicole","role":"aut"},{"display":"Veres, Gábor","role":"aut","given":"Gábor","family":"Veres"},{"family":"Karck","role":"aut","given":"Matthias","display":"Karck, Matthias"},{"display":"Szabó, Gábor","role":"aut","given":"Gábor","family":"Szabó"}],"origin":[{"dateIssuedDisp":"July 31, 2014","dateIssuedKey":"2014"}]} 
SRT |a WEYMANNALETOTALAORTI3120