High-mass capabilities of positive-ion and negative-ion direct analysis in real time mass spectrometry: letter
Of the ionic liquid 1-butyl-3-methylimidazolium (C+) tricyanomethide (A−) high-mass cluster ions of both positive ([CnAn-1]+) and negative ([Cn-1An]−) charge were generated and detected by direct analysis in real time (DART) Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS)....
Saved in:
| Main Author: | |
|---|---|
| Format: | Article (Journal) Editorial |
| Language: | English |
| Published: |
28 January 2016
|
| In: |
European journal of mass spectrometry
Year: 2016, Volume: 22, Issue: 1, Pages: 43-48 |
| ISSN: | 1751-6838 |
| DOI: | 10.1255/ejms.1409 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1255/ejms.1409 |
| Author Notes: | Jürgen H. Gross |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1726710645 | ||
| 003 | DE-627 | ||
| 005 | 20230427082117.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200810s2016 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1255/ejms.1409 |2 doi | |
| 035 | |a (DE-627)1726710645 | ||
| 035 | |a (DE-599)KXP1726710645 | ||
| 035 | |a (OCoLC)1341354702 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 30 |2 sdnb | ||
| 100 | 1 | |a Gross, Jürgen H. |d 1963- |e VerfasserIn |0 (DE-588)1028129734 |0 (DE-627)730387143 |0 (DE-576)375656391 |4 aut | |
| 245 | 1 | 0 | |a High-mass capabilities of positive-ion and negative-ion direct analysis in real time mass spectrometry |b letter |c Jürgen H. Gross |
| 264 | 1 | |c 28 January 2016 | |
| 300 | |a 6 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 10.08.2020 | ||
| 520 | |a Of the ionic liquid 1-butyl-3-methylimidazolium (C+) tricyanomethide (A−) high-mass cluster ions of both positive ([CnAn-1]+) and negative ([Cn-1An]−) charge were generated and detected by direct analysis in real time (DART) Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS). After optimization of the settings of the DART ionization source and of the mass analyser, ions of m/z values unprecedented in DART-MS were detected. Thus, the upper m/z limits of positive-ion and negative-ion DART-MS were substantially expanded. Negative-ion DART-MS delivered cluster ions up to [C15A16]−, m/z 3527 (nominal mass of monoisotopic ion), while positive-ion DART-MS even yielded ions up to [C30A29]+, m/z 6784. The identification of the cluster ions is supported by their accurate mass and exact mass differences corresponding to CA between adjacent cluster ion peaks. | ||
| 773 | 0 | 8 | |i Enthalten in |t European journal of mass spectrometry |d London : Sage Publishing, 2000 |g 22(2016), 1, Seite 43-48 |h Online-Ressource |w (DE-627)320612368 |w (DE-600)2021540-X |w (DE-576)335274781 |x 1751-6838 |7 nnas |a High-mass capabilities of positive-ion and negative-ion direct analysis in real time mass spectrometry letter |
| 773 | 1 | 8 | |g volume:22 |g year:2016 |g number:1 |g pages:43-48 |g extent:6 |a High-mass capabilities of positive-ion and negative-ion direct analysis in real time mass spectrometry letter |
| 856 | 4 | 0 | |u https://doi.org/10.1255/ejms.1409 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200810 | ||
| 993 | |a Editorial | ||
| 994 | |a 2016 | ||
| 998 | |g 1028129734 |a Gross, Jürgen H. |m 1028129734:Gross, Jürgen H. |d 120000 |d 120100 |e 120000PG1028129734 |e 120100PG1028129734 |k 0/120000/ |k 1/120000/120100/ |p 1 |x j |y j | ||
| 999 | |a KXP-PPN1726710645 |e 3737317917 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"origin":[{"dateIssuedDisp":"28 January 2016","dateIssuedKey":"2016"}],"id":{"eki":["1726710645"],"doi":["10.1255/ejms.1409"]},"name":{"displayForm":["Jürgen H. Gross"]},"physDesc":[{"extent":"6 S."}],"relHost":[{"id":{"issn":["1751-6838"],"eki":["320612368"],"zdb":["2021540-X"]},"origin":[{"dateIssuedDisp":"2000-","publisher":"Sage Publishing ; IM Publications","dateIssuedKey":"2000","publisherPlace":"London ; Chichester"}],"name":{"displayForm":["published in association with British Mass Spectrometry Society"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"subtitle":"EJMS","title":"European journal of mass spectrometry","title_sort":"European journal of mass spectrometry"}],"part":{"year":"2016","issue":"1","pages":"43-48","text":"22(2016), 1, Seite 43-48","volume":"22","extent":"6"},"titleAlt":[{"title":"EJMS"}],"pubHistory":["Volume 6, issue 1 (February 2000)-"],"recId":"320612368","language":["eng"],"disp":"High-mass capabilities of positive-ion and negative-ion direct analysis in real time mass spectrometry letterEuropean journal of mass spectrometry","type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 10.06.2022"]}],"title":[{"subtitle":"letter","title":"High-mass capabilities of positive-ion and negative-ion direct analysis in real time mass spectrometry","title_sort":"High-mass capabilities of positive-ion and negative-ion direct analysis in real time mass spectrometry"}],"person":[{"given":"Jürgen H.","family":"Gross","role":"aut","display":"Gross, Jürgen H.","roleDisplay":"VerfasserIn"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 10.08.2020"],"recId":"1726710645","language":["eng"]} | ||
| SRT | |a GROSSJUERGHIGHMASSCA2820 | ||