Improved procedure for dendrimer-based mass calibration in matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry

A procedure is described that results in a substantial increase in signal intensity and in improved accuracy of positive-ion mass calibration when using commercially available kits of monodisperse dendrimers (SpheriCal®) in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS)....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Gross, Jürgen H. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 18 June 2016
In: Analytical and bioanalytical chemistry
Year: 2016, Jahrgang: 408, Heft: 21, Pages: 5945-5951
ISSN:1618-2650
DOI:10.1007/s00216-016-9714-6
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s00216-016-9714-6
Volltext
Verfasserangaben:Jürgen H. Gross

MARC

LEADER 00000caa a2200000 c 4500
001 1726779823
003 DE-627
005 20230427082122.0
007 cr uuu---uuuuu
008 200811s2016 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00216-016-9714-6  |2 doi 
035 |a (DE-627)1726779823 
035 |a (DE-599)KXP1726779823 
035 |a (OCoLC)1341354694 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 30  |2 sdnb 
100 1 |a Gross, Jürgen H.  |d 1963-  |e VerfasserIn  |0 (DE-588)1028129734  |0 (DE-627)730387143  |0 (DE-576)375656391  |4 aut 
245 1 0 |a Improved procedure for dendrimer-based mass calibration in matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry  |c Jürgen H. Gross 
264 1 |c 18 June 2016 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 11.08.2020 
520 |a A procedure is described that results in a substantial increase in signal intensity and in improved accuracy of positive-ion mass calibration when using commercially available kits of monodisperse dendrimers (SpheriCal®) in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS). The peak intensities are amplified by an admixture of 2-[(2E)-3-(4-tert-butylphenyl)-2-methylprop-2-enylidene] malononitrile (DCTB) matrix to the kits comprising of 9-nitroanthracene matrix, sodium trifluoroacetate, and four dendrimers. Boosted ion formation then permits lower laser fluence to be used and thus yields enhanced mass resolution. Further, the number of reference peaks is doubled by doping the sample preparation with cesium ions. This results in four [M+Cs]+ ion signals in addition to four [M+Na]+ ion signals provided by the standard kit. Overall, the modified procedure notably reduces the consumption of the expensive calibration standard kits, while it increases mass resolution and enables the use of an advanced calibration algorithm requiring at least six reference peaks. 
773 0 8 |i Enthalten in  |t Analytical and bioanalytical chemistry  |d Berlin : Springer, 2002  |g 408(2016), 21, Seite 5945-5951  |h Online-Ressource  |w (DE-627)25372337X  |w (DE-600)1459122-4  |w (DE-576)072372842  |x 1618-2650  |7 nnas  |a Improved procedure for dendrimer-based mass calibration in matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry 
773 1 8 |g volume:408  |g year:2016  |g number:21  |g pages:5945-5951  |g extent:7  |a Improved procedure for dendrimer-based mass calibration in matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry 
856 4 0 |u https://doi.org/10.1007/s00216-016-9714-6  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200811 
993 |a Article 
994 |a 2016 
998 |g 1028129734  |a Gross, Jürgen H.  |m 1028129734:Gross, Jürgen H.  |d 120000  |d 120100  |e 120000PG1028129734  |e 120100PG1028129734  |k 0/120000/  |k 1/120000/120100/ 
999 |a KXP-PPN1726779823  |e 3738023631 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"recId":"1726779823","note":["Gesehen am 11.08.2020"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title":"Improved procedure for dendrimer-based mass calibration in matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry","title_sort":"Improved procedure for dendrimer-based mass calibration in matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry"}],"person":[{"roleDisplay":"VerfasserIn","display":"Gross, Jürgen H.","role":"aut","family":"Gross","given":"Jürgen H."}],"relHost":[{"part":{"extent":"7","text":"408(2016), 21, Seite 5945-5951","volume":"408","pages":"5945-5951","issue":"21","year":"2016"},"pubHistory":["372.2002 -"],"recId":"25372337X","language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Improved procedure for dendrimer-based mass calibration in matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometryAnalytical and bioanalytical chemistry","physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["1618-2650"],"zdb":["1459122-4"],"eki":["25372337X"]},"title":[{"title":"Analytical and bioanalytical chemistry","subtitle":"a merger of Fresenius' journal of analytical chemistry and Analusis","title_sort":"Analytical and bioanalytical chemistry"}],"origin":[{"dateIssuedKey":"2002","publisher":"Springer","dateIssuedDisp":"2002-","publisherPlace":"Berlin ; Heidelberg"}]}],"physDesc":[{"extent":"7 S."}],"id":{"eki":["1726779823"],"doi":["10.1007/s00216-016-9714-6"]},"origin":[{"dateIssuedKey":"2016","dateIssuedDisp":"18 June 2016"}],"name":{"displayForm":["Jürgen H. Gross"]}} 
SRT |a GROSSJUERGIMPROVEDPR1820