Dynamic expiratory airway collapse and evaluation of collateral ventilation with Chartis
We thank Gesierich et al 1 for raising some important issues regarding the evaluation of collateral ventilation using the Chartis flow catheter. In our review, we only provided two classical examples of Chartis expiratory flow and inspiratory pressure results; one from a patient with no collateral v...
Gespeichert in:
| Hauptverfasser: | , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2014
|
| In: |
Thorax
Year: 2013, Jahrgang: 69, Heft: 3, Pages: 290-291 |
| ISSN: | 1468-3296 |
| DOI: | 10.1136/thoraxjnl-2013-204875 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1136/thoraxjnl-2013-204875 Verlag, lizenzpflichtig, Volltext: https://thorax.bmj.com/content/69/3/290 |
| Verfasserangaben: | Pallav L. Shah, Felix J. F. Herth |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1726816389 | ||
| 003 | DE-627 | ||
| 005 | 20220818173247.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200812r20142013xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1136/thoraxjnl-2013-204875 |2 doi | |
| 035 | |a (DE-627)1726816389 | ||
| 035 | |a (DE-599)KXP1726816389 | ||
| 035 | |a (OCoLC)1341354940 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Shah, Pallav |e VerfasserIn |0 (DE-588)1163129259 |0 (DE-627)1027356710 |0 (DE-576)50780810X |4 aut | |
| 245 | 1 | 0 | |a Dynamic expiratory airway collapse and evaluation of collateral ventilation with Chartis |c Pallav L. Shah, Felix J. F. Herth |
| 264 | 1 | |c 2014 | |
| 300 | |a 2 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Published Online First: 19 December 2013 | ||
| 500 | |a Gesehen am 12.08.2020 | ||
| 520 | |a We thank Gesierich et al 1 for raising some important issues regarding the evaluation of collateral ventilation using the Chartis flow catheter. In our review, we only provided two classical examples of Chartis expiratory flow and inspiratory pressure results; one from a patient with no collateral ventilation and another from a patient with significant collateral ventilation.2 However, in clinical practice, a range of findings are observed that sit in the ‘grey zone’. - - In our practice and the results from an open-label multicentre study of valves where collateral ventilation was assessed with the Chartis system, it is evident that adequate assessment was not possible in about 15% of patients.3 A variety of factors may be responsible. Blockage of the catheter by secretions or apposition of the catheter against … | ||
| 534 | |c 2013 | ||
| 650 | 4 | |a Bronchoscopy | |
| 650 | 4 | |a Emphysema | |
| 650 | 4 | |a Lung Volume Reduction Surgery | |
| 700 | 1 | |a Herth, Felix |e VerfasserIn |0 (DE-588)1016095236 |0 (DE-627)705477568 |0 (DE-576)351509925 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Thorax |d London : BMJ Publishing Group, 1946 |g 69(2014), 3, Seite 290-291 |h Online-Ressource |w (DE-627)300184360 |w (DE-600)1481491-2 |w (DE-576)078941024 |x 1468-3296 |7 nnas |a Dynamic expiratory airway collapse and evaluation of collateral ventilation with Chartis |
| 773 | 1 | 8 | |g volume:69 |g year:2014 |g number:3 |g pages:290-291 |g extent:2 |a Dynamic expiratory airway collapse and evaluation of collateral ventilation with Chartis |
| 856 | 4 | 0 | |u https://doi.org/10.1136/thoraxjnl-2013-204875 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://thorax.bmj.com/content/69/3/290 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200812 | ||
| 993 | |a Article | ||
| 994 | |a 2014 | ||
| 998 | |g 1016095236 |a Herth, Felix |m 1016095236:Herth, Felix |d 910000 |d 950000 |d 950900 |e 910000PH1016095236 |e 950000PH1016095236 |e 950900PH1016095236 |k 0/910000/ |k 1/910000/950000/ |k 2/910000/950000/950900/ |p 2 |y j | ||
| 999 | |a KXP-PPN1726816389 |e 3738566716 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"note":["Published Online First: 19 December 2013","Gesehen am 12.08.2020"],"name":{"displayForm":["Pallav L. Shah, Felix J. F. Herth"]},"physDesc":[{"extent":"2 S."}],"title":[{"title_sort":"Dynamic expiratory airway collapse and evaluation of collateral ventilation with Chartis","title":"Dynamic expiratory airway collapse and evaluation of collateral ventilation with Chartis"}],"language":["eng"],"relHost":[{"titleAlt":[{"title":"eThorax"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"300184360","disp":"Dynamic expiratory airway collapse and evaluation of collateral ventilation with ChartisThorax","part":{"pages":"290-291","volume":"69","text":"69(2014), 3, Seite 290-291","year":"2014","extent":"2","issue":"3"},"pubHistory":["1.1946 -"],"corporate":[{"role":"isb","display":"Thoracic Society"},{"display":"British Medical Association","role":"isb"}],"origin":[{"publisher":"BMJ Publishing Group","publisherPlace":"London","dateIssuedKey":"1946","dateIssuedDisp":"1946-"}],"id":{"eki":["300184360"],"zdb":["1481491-2"],"issn":["1468-3296"]},"note":["Gesehen am 09.02.09","Beteil. Körp. anfangs: British Medical Association"],"title":[{"title_sort":"Thorax","title":"Thorax","subtitle":"an international journal of respiratory medicine ; official journal of the British Thoracic Society"}],"physDesc":[{"extent":"Online-Ressource"}],"language":["eng"]}],"person":[{"given":"Pallav","display":"Shah, Pallav","family":"Shah","role":"aut"},{"given":"Felix","family":"Herth","display":"Herth, Felix","role":"aut"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"2014","dateIssuedDisp":"2014"}],"recId":"1726816389","id":{"eki":["1726816389"],"doi":["10.1136/thoraxjnl-2013-204875"]}} | ||
| SRT | |a SHAHPALLAVDYNAMICEXP2014 | ||