Influence of weight and structure on biological behavior of polypropylene mesh prostheses placed at the esophageal hiatus

Background: Experimental knowledge about mesh behavior at the esophageal hiatus is rare, but such information is essential in order to find a safe and effective method of mesh reinforcement. This study aimed to investigate the influence of mesh structure on the biological behavior of polypropylene p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Senft, Jonas (VerfasserIn) , Gehrig, Tobias (VerfasserIn) , Lasitschka, Felix (VerfasserIn) , Linke, Georg R. (VerfasserIn) , Shevchenko, Maxym (VerfasserIn) , Bruckner, Thomas (VerfasserIn) , Kenngott, Hannes Götz (VerfasserIn) , Fischer, Lars (VerfasserIn) , Müller, Beat P. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 10 June 2014
In: Journal of laparoendoscopic & advanced surgical techniques
Year: 2014, Jahrgang: 24, Heft: 6, Pages: 383-390
ISSN:1557-9034
DOI:10.1089/lap.2013.0588
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1089/lap.2013.0588
Verlag, lizenzpflichtig, Volltext: https://www.liebertpub.com/doi/10.1089/lap.2013.0588
Volltext
Verfasserangaben:Jonas Senft, Tobias Gehrig, Felix Lasitschka, Georg R. Linke, Maxym Shevchenko, Thomas Bruckner, Hannes G. Kenngott, Lars Fischer, and Beat P. Müller-Stich

MARC

LEADER 00000caa a2200000 c 4500
001 1727090217
003 DE-627
005 20220818174819.0
007 cr uuu---uuuuu
008 200814s2014 xx |||||o 00| ||eng c
024 7 |a 10.1089/lap.2013.0588  |2 doi 
035 |a (DE-627)1727090217 
035 |a (DE-599)KXP1727090217 
035 |a (OCoLC)1341355440 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Senft, Jonas  |e VerfasserIn  |0 (DE-588)1052201148  |0 (DE-627)787984973  |0 (DE-576)40795077X  |4 aut 
245 1 0 |a Influence of weight and structure on biological behavior of polypropylene mesh prostheses placed at the esophageal hiatus  |c Jonas Senft, Tobias Gehrig, Felix Lasitschka, Georg R. Linke, Maxym Shevchenko, Thomas Bruckner, Hannes G. Kenngott, Lars Fischer, and Beat P. Müller-Stich 
264 1 |c 10 June 2014 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 14.08.2020 
520 |a Background: Experimental knowledge about mesh behavior at the esophageal hiatus is rare, but such information is essential in order to find a safe and effective method of mesh reinforcement. This study aimed to investigate the influence of mesh structure on the biological behavior of polypropylene prostheses placed at the hiatus.Materials and Methods: Twenty-four pigs in three groups of eight underwent implantation of heavyweight small-porous (HW-SP), heavyweight large-porous (HW-LP), or lightweight large-porous (LW-LP) circular polypropylene mesh at the hiatus. Eight weeks later, the meshes were explanted. Macroscopic analysis was performed evaluating mesh deformation, adhesions, and position relative to the hiatal margin. Histological analysis comprised evaluation of foreign body reaction and tissue integration by mononuclear cell count and immunostaining of Ki-67, collagen type I, and collagen type III.Results: No mesh-related complications occurred. Mesh shrinkage was observed within all groups and was the lowest for HW-LP, higher for HW-SP, and highest for LW-LP (13.8% versus 19.5% versus 25.5%; P<.001). The adhesion score was highest for HW-SP, lower for HW-LP, and lowest for LW-LP (11.0 versus 8.0 versus 6.0; P<.001). The collagen type I/III ratio was higher for HW-SP compared with HW-LP and LW-LP (3.1 versus 2.2 versus 1.8; P=.014).Conclusions: Heavyweight polypropylene meshes may be advantageous for application at the hiatus. They provide a solid fixation of the esophagogastric junction by adhesions, which may contribute to a reduction of hernia recurrence. In heavyweight meshes, the large-porous structure is associated with superior form stability, and small-porous meshes are superior with regard to solidity of tissue integration, which may prevent mesh migration. 
700 1 |a Gehrig, Tobias  |d 1975-  |e VerfasserIn  |0 (DE-588)133915808  |0 (DE-627)558729614  |0 (DE-576)278281745  |4 aut 
700 1 |a Lasitschka, Felix  |d 1979-  |e VerfasserIn  |0 (DE-588)140496343  |0 (DE-627)618903542  |0 (DE-576)318526077  |4 aut 
700 1 |a Linke, Georg R.  |d 1975-  |e VerfasserIn  |0 (DE-588)129150266  |0 (DE-627)390021326  |0 (DE-576)297510304  |4 aut 
700 1 |a Shevchenko, Maxym  |e VerfasserIn  |0 (DE-588)1065317786  |0 (DE-627)815856881  |0 (DE-576)424988682  |4 aut 
700 1 |a Bruckner, Thomas  |d 1956-  |e VerfasserIn  |0 (DE-588)136046215  |0 (DE-627)574429298  |0 (DE-576)300798768  |4 aut 
700 1 |a Kenngott, Hannes Götz  |d 1979-  |e VerfasserIn  |0 (DE-588)141469994  |0 (DE-627)62780117X  |0 (DE-576)324023065  |4 aut 
700 1 |a Fischer, Lars  |d 1971-  |e VerfasserIn  |0 (DE-588)122982606  |0 (DE-627)706116674  |0 (DE-576)302554661  |4 aut 
700 1 |a Müller, Beat P.  |d 1971-  |e VerfasserIn  |0 (DE-588)14066209X  |0 (DE-627)70374819X  |0 (DE-576)317992287  |4 aut 
773 0 8 |i Enthalten in  |t Journal of laparoendoscopic & advanced surgical techniques  |d New York, NY : Liebert, 1997  |g 24(2014), 6, Seite 383-390  |h Online-Ressource  |w (DE-627)325349851  |w (DE-600)2035583-X  |w (DE-576)273880322  |x 1557-9034  |7 nnas  |a Influence of weight and structure on biological behavior of polypropylene mesh prostheses placed at the esophageal hiatus 
773 1 8 |g volume:24  |g year:2014  |g number:6  |g pages:383-390  |g extent:8  |a Influence of weight and structure on biological behavior of polypropylene mesh prostheses placed at the esophageal hiatus 
856 4 0 |u https://doi.org/10.1089/lap.2013.0588  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.liebertpub.com/doi/10.1089/lap.2013.0588  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200814 
993 |a Article 
994 |a 2014 
998 |g 14066209X  |a Müller, Beat P.  |m 14066209X:Müller, Beat P.  |d 910000  |d 910200  |e 910000PM14066209X  |e 910200PM14066209X  |k 0/910000/  |k 1/910000/910200/  |p 9  |y j 
998 |g 122982606  |a Fischer, Lars  |m 122982606:Fischer, Lars  |d 910000  |d 910200  |d 50000  |e 910000PF122982606  |e 910200PF122982606  |e 50000PF122982606  |k 0/910000/  |k 1/910000/910200/  |k 0/50000/  |p 8 
998 |g 141469994  |a Kenngott, Hannes Götz  |m 141469994:Kenngott, Hannes Götz  |d 910000  |d 910200  |e 910000PK141469994  |e 910200PK141469994  |k 0/910000/  |k 1/910000/910200/  |p 7 
998 |g 136046215  |a Bruckner, Thomas  |m 136046215:Bruckner, Thomas  |d 910000  |d 999701  |e 910000PB136046215  |e 999701PB136046215  |k 0/910000/  |k 1/910000/999701/  |p 6 
998 |g 1065317786  |a Shevchenko, Maxym  |m 1065317786:Shevchenko, Maxym  |d 50000  |e 50000PS1065317786  |k 0/50000/  |p 5 
998 |g 129150266  |a Linke, Georg R.  |m 129150266:Linke, Georg R.  |d 50000  |e 50000PL129150266  |k 0/50000/  |p 4 
998 |g 140496343  |a Lasitschka, Felix  |m 140496343:Lasitschka, Felix  |d 910000  |d 912000  |e 910000PL140496343  |e 912000PL140496343  |k 0/910000/  |k 1/910000/912000/  |p 3 
998 |g 133915808  |a Gehrig, Tobias  |m 133915808:Gehrig, Tobias  |d 910000  |d 910200  |e 910000PG133915808  |e 910200PG133915808  |k 0/910000/  |k 1/910000/910200/  |p 2 
998 |g 1052201148  |a Senft, Jonas  |m 1052201148:Senft, Jonas  |p 1  |x j 
999 |a KXP-PPN1727090217  |e 3740047305 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedKey":"2014","dateIssuedDisp":"10 June 2014"}],"person":[{"display":"Senft, Jonas","given":"Jonas","role":"aut","family":"Senft"},{"family":"Gehrig","role":"aut","given":"Tobias","display":"Gehrig, Tobias"},{"given":"Felix","role":"aut","family":"Lasitschka","display":"Lasitschka, Felix"},{"display":"Linke, Georg R.","given":"Georg R.","role":"aut","family":"Linke"},{"display":"Shevchenko, Maxym","role":"aut","family":"Shevchenko","given":"Maxym"},{"given":"Thomas","family":"Bruckner","role":"aut","display":"Bruckner, Thomas"},{"family":"Kenngott","role":"aut","given":"Hannes Götz","display":"Kenngott, Hannes Götz"},{"given":"Lars","role":"aut","family":"Fischer","display":"Fischer, Lars"},{"display":"Müller, Beat P.","given":"Beat P.","role":"aut","family":"Müller"}],"language":["eng"],"id":{"doi":["10.1089/lap.2013.0588"],"eki":["1727090217"]},"recId":"1727090217","relHost":[{"recId":"325349851","id":{"issn":["1557-9034"],"eki":["325349851"],"zdb":["2035583-X"]},"origin":[{"dateIssuedDisp":"1997-","publisher":"Liebert","dateIssuedKey":"1997","publisherPlace":"New York, NY"}],"language":["eng"],"pubHistory":["7.1997 -"],"titleAlt":[{"title":"JLAST"},{"title":"Journal of laparoendoscopic & advanced surgical techniques / A"}],"part":{"text":"24(2014), 6, Seite 383-390","volume":"24","pages":"383-390","issue":"6","year":"2014","extent":"8"},"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Influence of weight and structure on biological behavior of polypropylene mesh prostheses placed at the esophageal hiatusJournal of laparoendoscopic & advanced surgical techniques","physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Journal of laparoendoscopic & advanced surgical techniques","title_sort":"Journal of laparoendoscopic & advanced surgical techniques"}],"note":["Teils auch als Ausg. A bez"]}],"name":{"displayForm":["Jonas Senft, Tobias Gehrig, Felix Lasitschka, Georg R. Linke, Maxym Shevchenko, Thomas Bruckner, Hannes G. Kenngott, Lars Fischer, and Beat P. Müller-Stich"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 14.08.2020"],"title":[{"title":"Influence of weight and structure on biological behavior of polypropylene mesh prostheses placed at the esophageal hiatus","title_sort":"Influence of weight and structure on biological behavior of polypropylene mesh prostheses placed at the esophageal hiatus"}],"physDesc":[{"extent":"8 S."}]} 
SRT |a SENFTJONASINFLUENCEO1020