Radiation exposure to eye lens and operator hands during endovascular procedures in hybrid operating rooms

Objective - The purpose of this study was to evaluate the radiation exposure of vascular surgeons' eye lens and fingers during complex endovascular procedures in modern hybrid operating rooms. - Methods - Prospective, nonrandomized multicenter study design. One hundred seventy-one consecutive p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Attigah, Nicolas (VerfasserIn) , Oikonomou, Kyriakos (VerfasserIn) , Hinz, Ulf (VerfasserIn) , Knoch, Thomas (VerfasserIn) , Demirel, Serdar (VerfasserIn) , Verhoeven, Eric L. G. (VerfasserIn) , Böckler, Dittmar (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2016
In: Journal of vascular surgery
Year: 2015, Jahrgang: 63, Heft: 1, Pages: 198-203
ISSN:1097-6809
DOI:10.1016/j.jvs.2015.08.051
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jvs.2015.08.051
Verlag, lizenzpflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S0741521415017565
Volltext
Verfasserangaben:Nicolas Attigah, MD, Kyriakos Oikonomou, MD, Ulf Hinz, MSc, Thomas Knoch, MSc, Serdar Demirel, MD, Eric Verhoeven, MD, PhD, and Dittmar Böckler, MD

MARC

LEADER 00000caa a2200000 c 4500
001 1727421108
003 DE-627
005 20240315110343.0
007 cr uuu---uuuuu
008 200819r20162015xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jvs.2015.08.051  |2 doi 
035 |a (DE-627)1727421108 
035 |a (DE-599)KXP1727421108 
035 |a (OCoLC)1341355702 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Attigah, Nicolas  |d 1968-  |e VerfasserIn  |0 (DE-588)124224903  |0 (DE-627)085720143  |0 (DE-576)185827721  |4 aut 
245 1 0 |a Radiation exposure to eye lens and operator hands during endovascular procedures in hybrid operating rooms  |c Nicolas Attigah, MD, Kyriakos Oikonomou, MD, Ulf Hinz, MSc, Thomas Knoch, MSc, Serdar Demirel, MD, Eric Verhoeven, MD, PhD, and Dittmar Böckler, MD 
264 1 |c 2016 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 21 October 2015 
500 |a Gesehen am 19.08.2020 
520 |a Objective - The purpose of this study was to evaluate the radiation exposure of vascular surgeons' eye lens and fingers during complex endovascular procedures in modern hybrid operating rooms. - Methods - Prospective, nonrandomized multicenter study design. One hundred seventy-one consecutive patients (138 male; median age, 72.5 years [interquartile range, 65-77 years]) underwent an endovascular procedure in a hybrid operating room between March 2012 and July 2013 in two vascular centers. The dose-area product (DAP), fluoroscopy time, operating time, and amount of contrast dye were registered prospectively. For radiation dose recordings, single-use dosimeters were attached at eye level and to the ring finger of the hand next to the radiation field of the operator for each endovascular procedure. Dose recordings were evaluated by an independent institution. Before the study, precursory investigations were obtained to simulate the radiation dose to eye lens and fingers with an Alderson phantome (RSD, Long Beach, Calif). - Results - Interventions were classified into six treatment categories: endovascular repair of infrarenal abdominal aneurysm (n = 65), thoracic endovascular aortic repair (n = 32), branched endovascular aortic repair for thoracoabdominal aneurysms (n = 17), fenestrated endovascular aortic repair for complex abdominal aortic aneurysm, (n = 25), iliac branched device (n = 8), and peripheral interventions (n = 24). There was a significant correlation in DAP between both lens (P < .01; r = 0.55) and finger (P < .01; r = 0.56) doses. The estimated fluoroscopy time to reach a radiation threshold of 20 mSv/y was 1404.10 minutes (90% confidence limit, 1160, 1650 minutes). According to correlation of the lens dose with the DAP an estimated cumulative DAP of 932,000 mGy/m2 (90% confidence limit, 822,000, 1,039,000) would be critical for a threshold of 20 mSv/y for the eyes. - Conclusions - Radiation protection is a serious issue for vascular surgeons because most complex endovascular procedures are delivering measurable radiation to the eyes. With the correlation of the DAP obtained in standard endovascular procedures a critical threshold of 20 mSv/y to the eyes can be predicted and thus an estimate of a potential harmful exposure to the eyes can be obtained. 
534 |c 2015 
700 1 |a Oikonomou, Kyriakos  |d 1981-  |e VerfasserIn  |0 (DE-588)1089080670  |0 (DE-627)850984882  |0 (DE-576)459954202  |4 aut 
700 1 |a Hinz, Ulf  |e VerfasserIn  |0 (DE-588)1022150499  |0 (DE-627)716927748  |0 (DE-576)175505284  |4 aut 
700 1 |a Knoch, Thomas  |e VerfasserIn  |0 (DE-588)1216179867  |0 (DE-627)1727420446  |4 aut 
700 1 |a Demirel, Serdar  |d 1977-  |e VerfasserIn  |0 (DE-588)130655481  |0 (DE-627)505290936  |0 (DE-576)298324970  |4 aut 
700 1 |a Verhoeven, Eric L. G.  |e VerfasserIn  |0 (DE-588)1079035753  |0 (DE-627)840103883  |0 (DE-576)452158176  |4 aut 
700 1 |a Böckler, Dittmar  |d 1966-  |e VerfasserIn  |0 (DE-588)1032367881  |0 (DE-627)738382868  |0 (DE-576)173503969  |4 aut 
773 0 8 |i Enthalten in  |t Journal of vascular surgery  |d Amsterdam [u.a.] : Elsevier, 1984  |g 63(2016), 1, Seite 198-203  |h Online-Ressource  |w (DE-627)302720146  |w (DE-600)1492043-8  |w (DE-576)088704807  |x 1097-6809  |7 nnas  |a Radiation exposure to eye lens and operator hands during endovascular procedures in hybrid operating rooms 
773 1 8 |g volume:63  |g year:2016  |g number:1  |g pages:198-203  |g extent:6  |a Radiation exposure to eye lens and operator hands during endovascular procedures in hybrid operating rooms 
856 4 0 |u https://doi.org/10.1016/j.jvs.2015.08.051  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0741521415017565  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200819 
993 |a Article 
994 |a 2016 
998 |g 1032367881  |a Böckler, Dittmar  |m 1032367881:Böckler, Dittmar  |d 910000  |d 910200  |e 910000PB1032367881  |e 910200PB1032367881  |k 0/910000/  |k 1/910000/910200/  |p 7  |y j 
998 |g 130655481  |a Demirel, Serdar  |m 130655481:Demirel, Serdar  |d 910000  |d 910200  |e 910000PD130655481  |e 910200PD130655481  |k 0/910000/  |k 1/910000/910200/  |p 5 
998 |g 1216179867  |a Knoch, Thomas  |m 1216179867:Knoch, Thomas  |d 910000  |d 910200  |e 910000PK1216179867  |e 910200PK1216179867  |k 0/910000/  |k 1/910000/910200/  |p 4 
998 |g 1022150499  |a Hinz, Ulf  |m 1022150499:Hinz, Ulf  |d 910000  |d 910200  |e 910000PH1022150499  |e 910200PH1022150499  |k 0/910000/  |k 1/910000/910200/  |p 3 
998 |g 124224903  |a Attigah, Nicolas  |m 124224903:Attigah, Nicolas  |d 910000  |d 910200  |e 910000PA124224903  |e 910200PA124224903  |k 0/910000/  |k 1/910000/910200/  |p 1  |x j 
999 |a KXP-PPN1727421108  |e 3741120685 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"6 S."}],"title":[{"title":"Radiation exposure to eye lens and operator hands during endovascular procedures in hybrid operating rooms","title_sort":"Radiation exposure to eye lens and operator hands during endovascular procedures in hybrid operating rooms"}],"language":["eng"],"note":["Available online 21 October 2015","Gesehen am 19.08.2020"],"name":{"displayForm":["Nicolas Attigah, MD, Kyriakos Oikonomou, MD, Ulf Hinz, MSc, Thomas Knoch, MSc, Serdar Demirel, MD, Eric Verhoeven, MD, PhD, and Dittmar Böckler, MD"]},"person":[{"given":"Nicolas","family":"Attigah","display":"Attigah, Nicolas","role":"aut"},{"display":"Oikonomou, Kyriakos","family":"Oikonomou","role":"aut","given":"Kyriakos"},{"role":"aut","family":"Hinz","display":"Hinz, Ulf","given":"Ulf"},{"given":"Thomas","family":"Knoch","display":"Knoch, Thomas","role":"aut"},{"family":"Demirel","display":"Demirel, Serdar","role":"aut","given":"Serdar"},{"given":"Eric L. G.","role":"aut","display":"Verhoeven, Eric L. G.","family":"Verhoeven"},{"family":"Böckler","display":"Böckler, Dittmar","role":"aut","given":"Dittmar"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"relHost":[{"pubHistory":["1.1984 -"],"disp":"Radiation exposure to eye lens and operator hands during endovascular procedures in hybrid operating roomsJournal of vascular surgery","part":{"text":"63(2016), 1, Seite 198-203","extent":"6","issue":"1","year":"2016","pages":"198-203","volume":"63"},"recId":"302720146","titleAlt":[{"title":"JVS"},{"title":"Vascular surgery"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 15.01.20"],"title":[{"title_sort":"Journal of vascular surgery","title":"Journal of vascular surgery"}],"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisherPlace":"Amsterdam [u.a.] ; St. Louis, Mo.","dateIssuedKey":"1984","dateIssuedDisp":"1984-","publisher":"Elsevier ; Mosby"}],"id":{"issn":["1097-6809"],"eki":["302720146"],"zdb":["1492043-8"]}}],"origin":[{"dateIssuedDisp":"2016","dateIssuedKey":"2016"}],"id":{"eki":["1727421108"],"doi":["10.1016/j.jvs.2015.08.051"]},"recId":"1727421108"} 
SRT |a ATTIGAHNICRADIATIONE2016