Microbiological control of cellular products: the relevance of the cellular matrix, incubation temperature, and atmosphere for the detection performance of automated culture systems

Background: The microbiological control of cellular products sometimes causes significant procedural issues for quality control laboratories. According to the European Pharmacopoeia (EP), the microbiological control of cellular products requires a 7- to 14-day incubation period at two different incu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Günther, Susanne-Katharina (VerfasserIn) , Mutters, Nico T. (VerfasserIn) , Günther, Frank (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2020
In: Transfusion medicine and hemotherapy
Year: 2020, Jahrgang: 47, Heft: 3, Pages: 254-263
ISSN:1660-3818
DOI:10.1159/000503397
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1159/000503397
Verlag, lizenzpflichtig, Volltext: https://www.karger.com/Article/FullText/503397
Volltext
Verfasserangaben:Susanne-Katharina Günther, Celina Geiss, Stefan J. Kaiser, Nico T. Mutters, Frank Günther

MARC

LEADER 00000caa a2200000 c 4500
001 1727459466
003 DE-627
005 20240415105657.0
007 cr uuu---uuuuu
008 200819s2020 xx |||||o 00| ||eng c
024 7 |a 10.1159/000503397  |2 doi 
035 |a (DE-627)1727459466 
035 |a (DE-599)KXP1727459466 
035 |a (OCoLC)1341355521 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Günther, Susanne-Katharina  |e VerfasserIn  |0 (DE-588)1216199264  |0 (DE-627)1727447867  |4 aut 
245 1 0 |a Microbiological control of cellular products  |b the relevance of the cellular matrix, incubation temperature, and atmosphere for the detection performance of automated culture systems  |c Susanne-Katharina Günther, Celina Geiss, Stefan J. Kaiser, Nico T. Mutters, Frank Günther 
264 1 |c 2020 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published online: October 22, 2019 
500 |a Gesehen am 19.08.2020 
520 |a Background: The microbiological control of cellular products sometimes causes significant procedural issues for quality control laboratories. According to the European Pharmacopoeia (EP), the microbiological control of cellular products requires a 7- to 14-day incubation period at two different incubation temperatures using aerobic and anaerobic growth media. However, the suitability of these test conditions for efficient quality control can be influenced by many conditions, such as the expected microbial spectrum of contamination or the texture and composition of the cellular product. Because of interference, direct inoculation and membrane filtration as reference methods of pharmacopoeia are largely unsuitable for the microbiological control of cellular products; therefore, alternative and, above all, automated methods are the focus of interest. Objective: The aim of our study was to evaluate the method suitability and possible effects of cell matrix, incubation temperature, and oxygen pressure on the detection performance of automated culture systems.Methods: The BacT/ALERT® 3D TM Dual T system (bioMérieux, Nürtingen, Germany) was used to evaluate the factors influencing automated microbiological control of cellular products. The tests were performed using microbial strains recommended by the EP for microbiological method suitability testing and additional relevant possible contaminants of human-derived stem-cell products under varying culture and cell matrix conditions. Results: All contaminants were detected by the system in the required period of 2-5 days. Low incubation temperatures (22°C) had overall negative effects on the detection kinetics of each type of microbial contamination. The adverse effects of the accompanying cell matrix on the detection properties of the system could be compensated in our study by incubation at 32°C in both the aerobic and the anaerobic culture conditions. Conclusion: Automated culture techniques represent a sufficient approach for the microbiological control of cellular products. The negative effects of the cell matrix and microbial contamination on the detection performance can be compensated by the application of variable culture conditions in the automated culture system. 
700 1 |a Mutters, Nico T.  |d 1980-  |e VerfasserIn  |0 (DE-588)136849687  |0 (DE-627)694710199  |0 (DE-576)288598962  |4 aut 
700 1 |a Günther, Frank  |d 1982-  |e VerfasserIn  |0 (DE-588)138444935  |0 (DE-627)602589037  |0 (DE-576)307130355  |4 aut 
773 0 8 |i Enthalten in  |t Transfusion medicine and hemotherapy  |d Basel : Karger, 2003  |g 47(2020), 3, Seite 254-263  |h Online-Ressource  |w (DE-627)360670695  |w (DE-600)2100533-3  |w (DE-576)11277542X  |x 1660-3818  |7 nnas  |a Microbiological control of cellular products the relevance of the cellular matrix, incubation temperature, and atmosphere for the detection performance of automated culture systems 
773 1 8 |g volume:47  |g year:2020  |g number:3  |g pages:254-263  |g extent:10  |a Microbiological control of cellular products the relevance of the cellular matrix, incubation temperature, and atmosphere for the detection performance of automated culture systems 
856 4 0 |u https://doi.org/10.1159/000503397  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.karger.com/Article/FullText/503397  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200819 
993 |a Article 
994 |a 2020 
998 |g 138444935  |a Günther, Frank  |m 138444935:Günther, Frank  |d 50000  |e 50000PG138444935  |k 0/50000/  |p 5  |y j 
998 |g 136849687  |a Mutters, Nico T.  |m 136849687:Mutters, Nico T.  |d 50000  |e 50000PM136849687  |k 0/50000/  |p 4 
999 |a KXP-PPN1727459466  |e 3741202509 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title_sort":"Microbiological control of cellular products","title":"Microbiological control of cellular products","subtitle":"the relevance of the cellular matrix, incubation temperature, and atmosphere for the detection performance of automated culture systems"}],"person":[{"role":"aut","roleDisplay":"VerfasserIn","display":"Günther, Susanne-Katharina","given":"Susanne-Katharina","family":"Günther"},{"roleDisplay":"VerfasserIn","display":"Mutters, Nico T.","role":"aut","family":"Mutters","given":"Nico T."},{"roleDisplay":"VerfasserIn","display":"Günther, Frank","role":"aut","family":"Günther","given":"Frank"}],"note":["Published online: October 22, 2019","Gesehen am 19.08.2020"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"recId":"1727459466","language":["eng"],"origin":[{"dateIssuedDisp":"2020","dateIssuedKey":"2020"}],"id":{"eki":["1727459466"],"doi":["10.1159/000503397"]},"name":{"displayForm":["Susanne-Katharina Günther, Celina Geiss, Stefan J. Kaiser, Nico T. Mutters, Frank Günther"]},"physDesc":[{"extent":"10 S."}],"relHost":[{"id":{"issn":["1660-3818"],"eki":["360670695"],"zdb":["2100533-3"]},"origin":[{"publisherPlace":"Basel","dateIssuedDisp":"2003-","publisher":"Karger","dateIssuedKey":"2003"}],"name":{"displayForm":["official organ of German Society for Transfusion Medicine and Immunohematology"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Transfusion medicine and hemotherapy","subtitle":"interdisciplinary journal for transfusion medicine, hemotherapy, immunohematology, and clinical hemostatis","title":"Transfusion medicine and hemotherapy"}],"titleAlt":[{"title":"offizielles Organ der Deutschen Gesellschaft für Transfusionsmedizin und Immunhämatologie ; interdisziplinäre Zeitschrift für Infusions- und Hämotherapie, Immunhämatologie und klinische Hämostaseologie"}],"part":{"year":"2020","issue":"3","pages":"254-263","volume":"47","text":"47(2020), 3, Seite 254-263","extent":"10"},"pubHistory":["30.2003 -"],"language":["eng","ger"],"recId":"360670695","disp":"Microbiological control of cellular products the relevance of the cellular matrix, incubation temperature, and atmosphere for the detection performance of automated culture systemsTransfusion medicine and hemotherapy","note":["Gesehen am 04.05.2023","Fortsetzung der Druck-Ausgabe","Ungezählte Beil.: Supplement"],"type":{"media":"Online-Ressource","bibl":"periodical"}}]} 
SRT |a GUENTHERSUMICROBIOLO2020