Machine perfusion in solid organ transplantation: where is the benefit?
Machine perfusion (MP) in solid organ transplantation has been a topic of variable importance for decades. At the dawn of organ transplantation, MP was one of the standard techniques for preservation; today’s gold standard for organ preservation for transplantation is cold storage (CS). The outcome...
Gespeichert in:
| Hauptverfasser: | , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
16 January 2014
|
| In: |
Langenbeck's archives of surgery
Year: 2014, Jahrgang: 399, Heft: 4, Pages: 421-427 |
| ISSN: | 1435-2451 |
| DOI: | 10.1007/s00423-014-1161-2 |
| Online-Zugang: | Resolving-System, lizenzpflichtig, Volltext: https://doi.org/10.1007/s00423-014-1161-2 Verlag, lizenzpflichtig, Volltext: https://link.springer.com/article/10.1007%2Fs00423-014-1161-2 |
| Verfasserangaben: | Helge Bruns, Peter Schemmer |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1727467590 | ||
| 003 | DE-627 | ||
| 005 | 20220818181141.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200819s2014 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s00423-014-1161-2 |2 doi | |
| 035 | |a (DE-627)1727467590 | ||
| 035 | |a (DE-599)KXP1727467590 | ||
| 035 | |a (OCoLC)1341355970 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Bruns, Helge |d 1976- |e VerfasserIn |0 (DE-588)133638561 |0 (DE-627)550286780 |0 (DE-576)299989119 |4 aut | |
| 245 | 1 | 0 | |a Machine perfusion in solid organ transplantation |b where is the benefit? |c Helge Bruns, Peter Schemmer |
| 264 | 1 | |c 16 January 2014 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 19.08.2020 | ||
| 520 | |a Machine perfusion (MP) in solid organ transplantation has been a topic of variable importance for decades. At the dawn of organ transplantation, MP was one of the standard techniques for preservation; today’s gold standard for organ preservation for transplantation is cold storage (CS). The outcome after transplantation of solid organs has tremendously improved over the last five decades. MP has been continuously under investigation and may be an option for organ preservation in selected cases; however, there is only little evidence from clinical trials that can be used to advocate for MP as a routine organ preservation method. | ||
| 700 | 1 | |a Schemmer, Peter |d 1967- |e VerfasserIn |0 (DE-588)1022604244 |0 (DE-627)717006794 |0 (DE-576)365668230 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Langenbeck's archives of surgery |d Berlin : Springer, 1998 |g 399(2014), 4, Seite 421-427 |h Online-Ressource |w (DE-627)253770440 |w (DE-600)1459390-7 |w (DE-576)072578564 |x 1435-2451 |7 nnas |a Machine perfusion in solid organ transplantation where is the benefit? |
| 773 | 1 | 8 | |g volume:399 |g year:2014 |g number:4 |g pages:421-427 |g extent:7 |a Machine perfusion in solid organ transplantation where is the benefit? |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00423-014-1161-2 |x Resolving-System |x Verlag |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://link.springer.com/article/10.1007%2Fs00423-014-1161-2 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200819 | ||
| 993 | |a Article | ||
| 994 | |a 2014 | ||
| 998 | |g 1022604244 |a Schemmer, Peter |m 1022604244:Schemmer, Peter |d 910000 |d 910200 |e 910000PS1022604244 |e 910200PS1022604244 |k 0/910000/ |k 1/910000/910200/ |p 2 |y j | ||
| 998 | |g 133638561 |a Bruns, Helge |m 133638561:Bruns, Helge |d 50000 |e 50000PB133638561 |k 0/50000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1727467590 |e 3741220221 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"id":{"eki":["1727467590"],"doi":["10.1007/s00423-014-1161-2"]},"origin":[{"dateIssuedKey":"2014","dateIssuedDisp":"16 January 2014"}],"name":{"displayForm":["Helge Bruns, Peter Schemmer"]},"relHost":[{"origin":[{"publisherPlace":"Berlin ; Heidelberg","dateIssuedDisp":"1998-","dateIssuedKey":"1998","publisher":"Springer"}],"id":{"zdb":["1459390-7"],"eki":["253770440"],"issn":["1435-2451"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Langenbeck's archives of surgery","title":"Langenbeck's archives of surgery","subtitle":"continues Langenbecks Archiv für Chirurgie : organ of the congresses of the German Society of Surgery : official journal of the German Association of Endocrine Surgeons, affiliated to the German Society of Surgery"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 24.03.25","Teils ungezählte Beil.: Supplement"],"disp":"Machine perfusion in solid organ transplantation where is the benefit?Langenbeck's archives of surgery","recId":"253770440","corporate":[{"role":"isb","display":"Deutsche Gesellschaft für Chirurgie","roleDisplay":"Herausgebendes Organ"}],"language":["eng"],"pubHistory":["Volume 383, issue 1 (March 1998)-"],"part":{"pages":"421-427","issue":"4","year":"2014","extent":"7","volume":"399","text":"399(2014), 4, Seite 421-427"}}],"physDesc":[{"extent":"7 S."}],"title":[{"title_sort":"Machine perfusion in solid organ transplantation","subtitle":"where is the benefit?","title":"Machine perfusion in solid organ transplantation"}],"person":[{"given":"Helge","family":"Bruns","role":"aut","display":"Bruns, Helge","roleDisplay":"VerfasserIn"},{"given":"Peter","family":"Schemmer","role":"aut","roleDisplay":"VerfasserIn","display":"Schemmer, Peter"}],"language":["eng"],"recId":"1727467590","type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 19.08.2020"]} | ||
| SRT | |a BRUNSHELGEMACHINEPER1620 | ||