Correct positioning of pedicle screws with a percutaneous minimal invasive system in spine trauma
Background - When performing minimally invasive spine surgery in trauma patients, a short operation time and a perfect positioning of pedicle screws are demanded. In this study, we show that a Minimally Invasive Pedicle Screw System allows both. - Methods - One hundred and twenty-one patients (131 f...
Gespeichert in:
| Hauptverfasser: | , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
28 April 2014
|
| In: |
Orthopaedics & traumatology
Year: 2014, Jahrgang: 100, Heft: 4, Pages: 389-393 |
| ISSN: | 1877-0568 |
| DOI: | 10.1016/j.otsr.2014.03.015 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.otsr.2014.03.015 Verlag, lizenzpflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S1877056814000899 |
| Verfasserangaben: | M. Tinelli, S. Matschke, M. Adams, P.A. Grützner, M. Münzberg, A.J. Suda |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1727508548 | ||
| 003 | DE-627 | ||
| 005 | 20240315110344.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200820s2014 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.otsr.2014.03.015 |2 doi | |
| 035 | |a (DE-627)1727508548 | ||
| 035 | |a (DE-599)KXP1727508548 | ||
| 035 | |a (OCoLC)1341356020 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Tinelli, Marco |d 1972- |e VerfasserIn |0 (DE-588)129932566 |0 (DE-627)484459643 |0 (DE-576)29790907X |4 aut | |
| 245 | 1 | 0 | |a Correct positioning of pedicle screws with a percutaneous minimal invasive system in spine trauma |c M. Tinelli, S. Matschke, M. Adams, P.A. Grützner, M. Münzberg, A.J. Suda |
| 264 | 1 | |c 28 April 2014 | |
| 300 | |a 5 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 20.08.2020 | ||
| 520 | |a Background - When performing minimally invasive spine surgery in trauma patients, a short operation time and a perfect positioning of pedicle screws are demanded. In this study, we show that a Minimally Invasive Pedicle Screw System allows both. - Methods - One hundred and twenty-one patients (131 fractures) with fractures between Th 3 and L 5 were treated. The most common fracture type was A3. We treated 52 females and 69 men with a mean age of 56.7 years. In 72% of the cases, the procedure was performed by two experienced spine surgeons. Postoperatively, all patients were examined using a CT-scan. In 61 patients, an anterior stabilization was additionally performed in 33 patients, vertebroplasty or cyphoplasty was performed. Fifteen patients underwent laminectomy. - Results - No patient postoperatively developed any additional neurological compromise. In total, 682 screws were placed. In the postoperative CT-scan, we found 16 screws (2.2%) in suboptimal position, 8 with medial and 8 with lateral deviation. - Discussion - With the Minimally Invasive Pedicle Screw System used in this study, spinal fractures can be treated in a short operation time with percutaneous stabilization and a correct positioning of the pedicle screws in almost 98%. In our study, no screw was so much malpositioned that revision surgery would have been necessary. - Level of evidence - Level III - Case-control study. | ||
| 650 | 4 | |a Minimally invasive spine fixation | |
| 650 | 4 | |a Navigation | |
| 650 | 4 | |a Pedicle screws | |
| 650 | 4 | |a Spine ORIF | |
| 700 | 1 | |a Matschke, Stefan |d 1962- |e VerfasserIn |0 (DE-588)121685977 |0 (DE-627)705616428 |0 (DE-576)292829760 |4 aut | |
| 700 | 1 | |a Adams, Michael A. |e VerfasserIn |0 (DE-588)1016127685 |0 (DE-627)705481492 |0 (DE-576)351549579 |4 aut | |
| 700 | 1 | |a Grützner, Paul Alfred |d 1962- |e VerfasserIn |0 (DE-588)111926688 |0 (DE-627)728553473 |0 (DE-576)372572863 |4 aut | |
| 700 | 1 | |a Münzberg, Matthias |d 1977- |e VerfasserIn |0 (DE-588)132228254 |0 (DE-627)519546385 |0 (DE-576)299017656 |4 aut | |
| 700 | 1 | |a Höppchen, Arnold |d 1978- |e VerfasserIn |0 (DE-588)1075748429 |0 (DE-627)833789589 |0 (DE-576)444622861 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Orthopaedics & traumatology |d Paris : Elsevier Masson, 2009 |g 100(2014), 4, Seite 389-393 |h Online-Ressource |w (DE-627)594779669 |w (DE-600)2486602-7 |w (DE-576)304868957 |x 1877-0568 |7 nnas |a Correct positioning of pedicle screws with a percutaneous minimal invasive system in spine trauma |
| 773 | 1 | 8 | |g volume:100 |g year:2014 |g number:4 |g pages:389-393 |g extent:5 |a Correct positioning of pedicle screws with a percutaneous minimal invasive system in spine trauma |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.otsr.2014.03.015 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S1877056814000899 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200820 | ||
| 993 | |a Article | ||
| 994 | |a 2014 | ||
| 998 | |g 1075748429 |a Höppchen, Arnold |m 1075748429:Höppchen, Arnold |d 50000 |e 50000PH1075748429 |k 0/50000/ |p 6 |y j | ||
| 998 | |g 132228254 |a Münzberg, Matthias |m 132228254:Münzberg, Matthias |p 5 | ||
| 998 | |g 111926688 |a Grützner, Paul Alfred |m 111926688:Grützner, Paul Alfred |d 50000 |e 50000PG111926688 |k 0/50000/ |p 4 | ||
| 998 | |g 1016127685 |a Adams, Michael A. |m 1016127685:Adams, Michael A. |p 3 | ||
| 998 | |g 121685977 |a Matschke, Stefan |m 121685977:Matschke, Stefan |d 50000 |e 50000PM121685977 |k 0/50000/ |p 2 | ||
| 998 | |g 129932566 |a Tinelli, Marco |m 129932566:Tinelli, Marco |p 1 |x j | ||
| 999 | |a KXP-PPN1727508548 |e 3741288446 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"recId":"1727508548","title":[{"title":"Correct positioning of pedicle screws with a percutaneous minimal invasive system in spine trauma","title_sort":"Correct positioning of pedicle screws with a percutaneous minimal invasive system in spine trauma"}],"name":{"displayForm":["M. Tinelli, S. Matschke, M. Adams, P.A. Grützner, M. Münzberg, A.J. Suda"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"physDesc":[{"extent":"5 S."}],"note":["Gesehen am 20.08.2020"],"person":[{"given":"Marco","role":"aut","display":"Tinelli, Marco","roleDisplay":"VerfasserIn","family":"Tinelli"},{"roleDisplay":"VerfasserIn","family":"Matschke","role":"aut","display":"Matschke, Stefan","given":"Stefan"},{"roleDisplay":"VerfasserIn","family":"Adams","given":"Michael A.","role":"aut","display":"Adams, Michael A."},{"family":"Grützner","roleDisplay":"VerfasserIn","display":"Grützner, Paul Alfred","role":"aut","given":"Paul Alfred"},{"display":"Münzberg, Matthias","role":"aut","given":"Matthias","roleDisplay":"VerfasserIn","family":"Münzberg"},{"given":"Arnold","display":"Höppchen, Arnold","role":"aut","roleDisplay":"VerfasserIn","family":"Höppchen"}],"origin":[{"dateIssuedDisp":"28 April 2014","dateIssuedKey":"2014"}],"id":{"doi":["10.1016/j.otsr.2014.03.015"],"eki":["1727508548"]},"relHost":[{"title":[{"subtitle":"surgery & research ; OTSR","title_sort":"Orthopaedics & traumatology","title":"Orthopaedics & traumatology"}],"disp":"Correct positioning of pedicle screws with a percutaneous minimal invasive system in spine traumaOrthopaedics & traumatology","recId":"594779669","pubHistory":["95.2009 -"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"corporate":[{"roleDisplay":"Herausgebendes Organ","display":"Société Française de Chirurgie Orthopédique et Traumatologie","role":"isb"}],"part":{"text":"100(2014), 4, Seite 389-393","pages":"389-393","year":"2014","issue":"4","volume":"100","extent":"5"},"note":["Gesehen am 31.05.23"],"physDesc":[{"extent":"Online-Ressource"}],"titleAlt":[{"title":"RCO"},{"title":"OTSR"},{"title":"Orthopaedics and traumatology"}],"id":{"eki":["594779669"],"issn":["1877-0568"],"zdb":["2486602-7"]},"origin":[{"publisherPlace":"Paris","dateIssuedDisp":"2009-","publisher":"Elsevier Masson","dateIssuedKey":"2009"}]}]} | ||
| SRT | |a TINELLIMARCORRECTPOS2820 | ||