Nuclear Overhauser Enhancement mediated chemical exchange saturation transfer imaging at 7 Tesla in glioblastoma patients

Background and Purpose Nuclear Overhauser Enhancement (NOE) mediated chemical exchange saturation transfer (CEST) is a novel magnetic resonance imaging (MRI) technique on the basis of saturation transfer between exchanging protons of tissue proteins and bulk water. The purpose of this study was to e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Paech, Daniel (VerfasserIn) , Zaiss, Moritz (VerfasserIn) , Meissner, Jan-Eric (VerfasserIn) , Windschuh, Johannes (VerfasserIn) , Wiestler, Benedikt (VerfasserIn) , Bachert, Peter (VerfasserIn) , Neumann, Jan-Oliver (VerfasserIn) , Vollmuth, Philipp (VerfasserIn) , Schlemmer, Heinz-Peter (VerfasserIn) , Wick, Wolfgang (VerfasserIn) , Nagel, Armin Michael (VerfasserIn) , Heiland, Sabine (VerfasserIn) , Ladd, Mark E. (VerfasserIn) , Bendszus, Martin (VerfasserIn) , Radbruch, Alexander (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: August 11, 2014
In: PLOS ONE
Year: 2014, Jahrgang: 9, Heft: 8
ISSN:1932-6203
DOI:10.1371/journal.pone.0104181
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1371/journal.pone.0104181
Verlag, lizenzpflichtig, Volltext: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0104181
Volltext
Verfasserangaben:Daniel Paech, Moritz Zaiss, Jan-Eric Meissner, Johannes Windschuh, Benedikt Wiestler, Peter Bachert, Jan Oliver Neumann, Philipp Kickingereder, Heinz-Peter Schlemmer, Wolfgang Wick, Armin Michael Nagel, Sabine Heiland, Mark Edward Ladd, Martin Bendszus, Alexander Radbruch
Beschreibung
Zusammenfassung:Background and Purpose Nuclear Overhauser Enhancement (NOE) mediated chemical exchange saturation transfer (CEST) is a novel magnetic resonance imaging (MRI) technique on the basis of saturation transfer between exchanging protons of tissue proteins and bulk water. The purpose of this study was to evaluate and compare the information provided by three dimensional NOE mediated CEST at 7 Tesla (7T) and standard MRI in glioblastoma patients. Patients and Methods Twelve patients with newly diagnosed histologically proven glioblastoma were enrolled in this prospective ethics committee-approved study. NOE mediated CEST contrast was acquired with a modified three-dimensional gradient-echo sequence and asymmetry analysis was conducted at 3.3ppm (B1 = 0.7 µT) to calculate the magnetization transfer ratio asymmetry (MTRasym). Contrast enhanced T1 (CE-T1) and T2-weighted images were acquired at 3T and used for data co-registration and comparison. Results Mean NOE mediated CEST signal based on MTRasym values over all patients was significantly increased (p<0.001) in CE-T1 tumor (−1.99±1.22%), tumor necrosis (−1.36±1.30%) and peritumoral CEST hyperintensities (PTCH) within T2 edema margins (−3.56±1.24%) compared to contralateral normal appearing white matter (−8.38±1.19%). In CE-T1 tumor (p = 0.015) and tumor necrosis (p<0.001) mean MTRasym values were significantly higher than in PTCH. Extent of the surrounding tumor hyperintensity was smaller in eight out of 12 patients on CEST than on T2-weighted images, while four displayed at equal size. In all patients, isolated high intensity regions (0.40±2.21%) displayed on CEST within the CE-T1 tumor that were not discernible on CE-T1 or T2-weighted images. Conclusion NOE mediated CEST Imaging at 7T provides additional information on the structure of peritumoral hyperintensities in glioblastoma and displays isolated high intensity regions within the CE-T1 tumor that cannot be acquired on CE-T1 or T2-weighted images. Further research is needed to determine the origin of NOE mediated CEST and possible clinical applications such as therapy assessment or biopsy planning.
Beschreibung:Gesehen am 25.08.2020
Beschreibung:Online Resource
ISSN:1932-6203
DOI:10.1371/journal.pone.0104181