High-mass cluster ions of ionic liquids in positive-ion and negative-ion DART-MS and their application for wide-range mass calibrations
Eight ionic liquids (ILs) are subjected to both positive-ion and negative-ion direct analyses in real time (DART) Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS). First, their ability to deliver evenly distributed cluster ion series covering a wide m/z range is explored. Th...
Gespeichert in:
| 1. Verfasser: | |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
15 March 2014
|
| In: |
Analytical and bioanalytical chemistry
Year: 2014, Jahrgang: 406, Heft: 12, Pages: 2853-2862 |
| ISSN: | 1618-2650 |
| DOI: | 10.1007/s00216-014-7720-0 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s00216-014-7720-0 |
| Verfasserangaben: | Jürgen H. Gross |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1729025900 | ||
| 003 | DE-627 | ||
| 005 | 20230426165509.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200907s2014 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s00216-014-7720-0 |2 doi | |
| 035 | |a (DE-627)1729025900 | ||
| 035 | |a (DE-599)KXP1729025900 | ||
| 035 | |a (OCoLC)1341358906 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 30 |2 sdnb | ||
| 100 | 1 | |a Gross, Jürgen H. |d 1963- |e VerfasserIn |0 (DE-588)1028129734 |0 (DE-627)730387143 |0 (DE-576)375656391 |4 aut | |
| 245 | 1 | 0 | |a High-mass cluster ions of ionic liquids in positive-ion and negative-ion DART-MS and their application for wide-range mass calibrations |c Jürgen H. Gross |
| 264 | 1 | |c 15 March 2014 | |
| 300 | |a 10 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 07.09.2020 | ||
| 520 | |a Eight ionic liquids (ILs) are subjected to both positive-ion and negative-ion direct analyses in real time (DART) Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS). First, their ability to deliver evenly distributed cluster ion series covering a wide m/z range is explored. Then, one of the ILs exhibiting particularly useful cluster ion series in either ion polarity is applied for mass calibration. Using 1-butyl-3-methylimidazolium tricyanomethide delivers positive cluster ions suitable for mass calibration in the m/z 100-4,000 range and covers the m/z 100-2,000 range in negative-ion DART-MS. The corresponding mass reference lists are provided for either polarity. Furthermore, based on 1-butyl-3-methylimidazolium tricyanomethide, a high-mass record of m/z > 5,000 for positive-ion DART-MS is presented. The mass calibration procedure is finally validated by application to established standard compounds such as polydimethylsiloxanes, perfluorononanoic acid, and Ultramark 1621, a mixture of hexakis (fluoroalkoxy) phosphazenes. Further proof is presented by consistent exact mass differences between adjacent cluster ions. | ||
| 773 | 0 | 8 | |i Enthalten in |t Analytical and bioanalytical chemistry |d Berlin : Springer, 2002 |g 406(2014), 12, Seite 2853-2862 |h Online-Ressource |w (DE-627)25372337X |w (DE-600)1459122-4 |w (DE-576)072372842 |x 1618-2650 |7 nnas |a High-mass cluster ions of ionic liquids in positive-ion and negative-ion DART-MS and their application for wide-range mass calibrations |
| 773 | 1 | 8 | |g volume:406 |g year:2014 |g number:12 |g pages:2853-2862 |g extent:10 |a High-mass cluster ions of ionic liquids in positive-ion and negative-ion DART-MS and their application for wide-range mass calibrations |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00216-014-7720-0 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200907 | ||
| 993 | |a Article | ||
| 994 | |a 2014 | ||
| 998 | |g 1028129734 |a Gross, Jürgen H. |m 1028129734:Gross, Jürgen H. |d 120000 |d 120100 |e 120000PG1028129734 |e 120100PG1028129734 |k 0/120000/ |k 1/120000/120100/ |p 1 |x j |y j | ||
| 999 | |a KXP-PPN1729025900 |e 3747435106 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"physDesc":[{"extent":"10 S."}],"relHost":[{"recId":"25372337X","language":["eng"],"disp":"High-mass cluster ions of ionic liquids in positive-ion and negative-ion DART-MS and their application for wide-range mass calibrationsAnalytical and bioanalytical chemistry","type":{"media":"Online-Ressource","bibl":"periodical"},"physDesc":[{"extent":"Online-Ressource"}],"part":{"volume":"406","text":"406(2014), 12, Seite 2853-2862","extent":"10","year":"2014","pages":"2853-2862","issue":"12"},"pubHistory":["372.2002 -"],"id":{"eki":["25372337X"],"zdb":["1459122-4"],"issn":["1618-2650"]},"title":[{"title_sort":"Analytical and bioanalytical chemistry","subtitle":"a merger of Fresenius' journal of analytical chemistry and Analusis","title":"Analytical and bioanalytical chemistry"}],"origin":[{"dateIssuedDisp":"2002-","publisher":"Springer","dateIssuedKey":"2002","publisherPlace":"Berlin ; Heidelberg"}]}],"origin":[{"dateIssuedKey":"2014","dateIssuedDisp":"15 March 2014"}],"id":{"doi":["10.1007/s00216-014-7720-0"],"eki":["1729025900"]},"name":{"displayForm":["Jürgen H. Gross"]},"note":["Gesehen am 07.09.2020"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"recId":"1729025900","title":[{"title":"High-mass cluster ions of ionic liquids in positive-ion and negative-ion DART-MS and their application for wide-range mass calibrations","title_sort":"High-mass cluster ions of ionic liquids in positive-ion and negative-ion DART-MS and their application for wide-range mass calibrations"}],"person":[{"family":"Gross","given":"Jürgen H.","roleDisplay":"VerfasserIn","display":"Gross, Jürgen H.","role":"aut"}]} | ||
| SRT | |a GROSSJUERGHIGHMASSCL1520 | ||