Theoretical model of the single spin-echo relaxation time for spherical magnetic perturbers

Purpose Magnetically labeled cells and tissue iron deposits provide qualitative means to detect and monitor cardiovascular and cerebrovascular diseases with magnetic resonance imaging. However, to quantitatively examine the extent of pathological micromorphological changes, detailed knowledge about...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kurz, Felix T. (VerfasserIn) , Kampf, Thomas (VerfasserIn) , Heiland, Sabine (VerfasserIn) , Bendszus, Martin (VerfasserIn) , Schlemmer, Heinz-Peter (VerfasserIn) , Ziener, Christian H. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 24 February 2014
In: Magnetic resonance in medicine
Year: 2014, Jahrgang: 71, Heft: 5, Pages: 1888-1895
ISSN:1522-2594
DOI:10.1002/mrm.25196
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1002/mrm.25196
Verlag, lizenzpflichtig, Volltext: https://www.onlinelibrary.wiley.com/doi/abs/10.1002/mrm.25196
Volltext
Verfasserangaben:Felix T. Kurz, Thomas Kampf, Sabine Heiland, Martin Bendszus, Heinz-Peter Schlemmer, and Christian H. Ziener

MARC

LEADER 00000caa a2200000 c 4500
001 1729094147
003 DE-627
005 20230426165511.0
007 cr uuu---uuuuu
008 200908s2014 xx |||||o 00| ||eng c
024 7 |a 10.1002/mrm.25196  |2 doi 
035 |a (DE-627)1729094147 
035 |a (DE-599)KXP1729094147 
035 |a (OCoLC)1341358545 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Kurz, Felix T.  |d 1981-  |e VerfasserIn  |0 (DE-588)1043285474  |0 (DE-627)771321066  |0 (DE-576)394610342  |4 aut 
245 1 0 |a Theoretical model of the single spin-echo relaxation time for spherical magnetic perturbers  |c Felix T. Kurz, Thomas Kampf, Sabine Heiland, Martin Bendszus, Heinz-Peter Schlemmer, and Christian H. Ziener 
264 1 |c 24 February 2014 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 08.09.2020 
520 |a Purpose Magnetically labeled cells and tissue iron deposits provide qualitative means to detect and monitor cardiovascular and cerebrovascular diseases with magnetic resonance imaging. However, to quantitatively examine the extent of pathological micromorphological changes, detailed knowledge about microstructural parameters and relaxation times is required. Methods The complex geometrical arrangement of spherical magnetic perturbers is considered in an external magnetic field. They create a magnetic dipole field, whose corresponding spin-echo formation is investigated by analyzing the diffusion process in the dephasing volume. Quantitative predictions of the present analysis are compared with experimental data and empirical models. Results Single spin-echo relaxation times can be characterized by morphological parameters such as magnetic particle concentration and size as well as tissue diffusion coefficient and local magnetic susceptibility properties. As expected, no formation of a static dephasing plateau is observed in contrast to the gradient-echo relaxation time. Instead, the relaxation rate drops for large particle sizes and exhibits a prominent maximal value at intermediate sizes. These findings agree well with experimental data and previous theoretical results. Conclusion Obtained results for the single spin-echo relaxation time allow to accurately quantify pathological processes in neurodegenerative disease and migration dynamics of magnetically labeled cells with the help of magnetic resonance imaging. Magn Reson Med 71:1888-1895, 2014. © 2014 Wiley Periodicals, Inc. 
650 4 |a relaxation time 
650 4 |a spherical magnetic perturber 
650 4 |a spin echo 
700 1 |a Kampf, Thomas  |e VerfasserIn  |4 aut 
700 1 |a Heiland, Sabine  |e VerfasserIn  |0 (DE-588)106732626X  |0 (DE-627)818624450  |0 (DE-576)426561368  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
700 1 |a Schlemmer, Heinz-Peter  |d 1961-  |e VerfasserIn  |0 (DE-588)1025559967  |0 (DE-627)722927142  |0 (DE-576)17334805X  |4 aut 
700 1 |a Ziener, Christian H.  |d 1978-  |e VerfasserIn  |0 (DE-588)137982755  |0 (DE-627)59885309X  |0 (DE-576)306117355  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in medicine  |d New York, NY [u.a.] : Wiley-Liss, 1984  |g 71(2014), 5, Seite 1888-1895  |h Online-Ressource  |w (DE-627)303257040  |w (DE-600)1493786-4  |w (DE-576)096290455  |x 1522-2594  |7 nnas  |a Theoretical model of the single spin-echo relaxation time for spherical magnetic perturbers 
773 1 8 |g volume:71  |g year:2014  |g number:5  |g pages:1888-1895  |g extent:8  |a Theoretical model of the single spin-echo relaxation time for spherical magnetic perturbers 
856 4 0 |u https://doi.org/10.1002/mrm.25196  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.onlinelibrary.wiley.com/doi/abs/10.1002/mrm.25196  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200908 
993 |a Article 
994 |a 2014 
998 |g 1025559967  |a Schlemmer, Heinz-Peter  |m 1025559967:Schlemmer, Heinz-Peter  |d 50000  |e 50000PS1025559967  |k 0/50000/  |p 5 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911100  |e 910000PB1032676426  |e 911100PB1032676426  |k 0/910000/  |k 1/910000/911100/  |p 4 
998 |g 137982755  |a Ziener, Christian H.  |m 137982755:Ziener, Christian H.  |p 6  |y j 
998 |g 106732626X  |a Heiland, Sabine  |m 106732626X:Heiland, Sabine  |d 910000  |d 911100  |e 910000PH106732626X  |e 911100PH106732626X  |k 0/910000/  |k 1/910000/911100/  |p 3 
998 |g 1043285474  |a Kurz, Felix T.  |m 1043285474:Kurz, Felix T.  |d 910000  |d 911100  |e 910000PK1043285474  |e 911100PK1043285474  |k 0/910000/  |k 1/910000/911100/  |p 1  |x j 
999 |a KXP-PPN1729094147  |e 3747576788 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedKey":"2014","dateIssuedDisp":"24 February 2014"}],"note":["Gesehen am 08.09.2020"],"physDesc":[{"extent":"8 S."}],"relHost":[{"disp":"Theoretical model of the single spin-echo relaxation time for spherical magnetic perturbersMagnetic resonance in medicine","language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"titleAlt":[{"title":"MRM"}],"part":{"volume":"71","year":"2014","extent":"8","pages":"1888-1895","text":"71(2014), 5, Seite 1888-1895","issue":"5"},"title":[{"title":"Magnetic resonance in medicine","title_sort":"Magnetic resonance in medicine","subtitle":"MRM ; an official journal of the International Society for Magnetic Resonance in Medicine"}],"pubHistory":["1.1984 -"],"id":{"eki":["303257040"],"issn":["1522-2594"],"zdb":["1493786-4"],"doi":["10.1002/(ISSN)1522-2594"]},"recId":"303257040","physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisherPlace":"New York, NY [u.a.]","dateIssuedKey":"1984","publisher":"Wiley-Liss","dateIssuedDisp":"1984-"}],"note":["Gesehen am 28.02.08"]}],"title":[{"title_sort":"Theoretical model of the single spin-echo relaxation time for spherical magnetic perturbers","title":"Theoretical model of the single spin-echo relaxation time for spherical magnetic perturbers"}],"person":[{"display":"Kurz, Felix T.","role":"aut","given":"Felix T.","family":"Kurz"},{"family":"Kampf","given":"Thomas","display":"Kampf, Thomas","role":"aut"},{"given":"Sabine","family":"Heiland","role":"aut","display":"Heiland, Sabine"},{"display":"Bendszus, Martin","role":"aut","given":"Martin","family":"Bendszus"},{"display":"Schlemmer, Heinz-Peter","role":"aut","family":"Schlemmer","given":"Heinz-Peter"},{"display":"Ziener, Christian H.","role":"aut","family":"Ziener","given":"Christian H."}],"recId":"1729094147","name":{"displayForm":["Felix T. Kurz, Thomas Kampf, Sabine Heiland, Martin Bendszus, Heinz-Peter Schlemmer, and Christian H. Ziener"]},"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"doi":["10.1002/mrm.25196"],"eki":["1729094147"]}} 
SRT |a KURZFELIXTTHEORETICA2420