Diagnostic accuracy of intraoperative CT-imaging in complex articular fractures: a cadaveric study

Anatomic reconstruction of articular fractures is one of the critical factors in later achieving good functional outcome. Intraoperative 3D imaging has been shown to offer better evaluation and therefore can significantly improve the results. The purpose of this study was to assess the difference be...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Luxenhofer, Miriam (VerfasserIn) , Beisemann, Nils (VerfasserIn) , Schnetzke, Marc (VerfasserIn) , Vetter, Sven Y. (VerfasserIn) , Grützner, Paul Alfred (VerfasserIn) , Franke, Jochen (VerfasserIn) , Keil, Holger (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 11 March 2020
In: Scientific reports
Year: 2020, Jahrgang: 10
ISSN:2045-2322
DOI:10.1038/s41598-020-61267-w
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1038/s41598-020-61267-w
Verlag, kostenfrei, Volltext: https://www.nature.com/articles/s41598-020-61267-w
Volltext
Verfasserangaben:M. Luxenhofer, N. Beisemann, M. Schnetzke, S.Y. Vetter, P.A. Grützner, J. Franke & H. Keil

MARC

LEADER 00000caa a2200000 c 4500
001 1731777086
003 DE-627
005 20210820055741.0
007 cr uuu---uuuuu
008 200914s2020 xx |||||o 00| ||eng c
024 7 |a 10.1038/s41598-020-61267-w  |2 doi 
035 |a (DE-627)1731777086 
035 |a (DE-599)KXP1731777086 
035 |a (OCoLC)1264384991 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Luxenhofer, Miriam  |d 1993-  |e VerfasserIn  |0 (DE-588)1217607234  |0 (DE-627)1731777604  |4 aut 
245 1 0 |a Diagnostic accuracy of intraoperative CT-imaging in complex articular fractures  |b a cadaveric study  |c M. Luxenhofer, N. Beisemann, M. Schnetzke, S.Y. Vetter, P.A. Grützner, J. Franke & H. Keil 
264 1 |c 11 March 2020 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 14.09.2020 
520 |a Anatomic reconstruction of articular fractures is one of the critical factors in later achieving good functional outcome. Intraoperative 3D imaging has been shown to offer better evaluation and therefore can significantly improve the results. The purpose of this study was to assess the difference between intraoperative three-dimensional fluoroscopy (3D) and intraoperative computed tomography (iCT) imaging regarding fracture reduction, implant placement and articular impressions in a distal humeral fracture model. AO type 13-B2 fracture pattern were created in upper extremity cadaver specimens. Articular step-offs, intra-articular screw placement and intraarticular impressions of different degrees of severity were created. All specimens had imaging performed. For each articular pattern 3D fluoroscopy in standard (3Ds) and high quality (3Dh) were performed (Arcadis Orbic, Siemens, Germany) as well as an intraoperative CT scan (iCT, Airo, Brainlab, Germany). Three observers evaluated all imaging studies regarding subjective and objective parameters. iCT is more precise than 3D fluoroscopic imaging for detection of articular impressions. Articular step-offs and intraarticular screw placement are similar for iCT and 3D. Subjective imaging quality is the highest for iCT and lowest for 3Ds. Intraoperative CT may be particularly useful in assessing articular impressions and providing a good subjective image quality for the surgeon. 
700 1 |a Beisemann, Nils  |d 1986-  |e VerfasserIn  |0 (DE-588)1069142913  |0 (DE-627)821371940  |0 (DE-576)428434991  |4 aut 
700 1 |a Schnetzke, Marc  |d 1984-  |e VerfasserIn  |0 (DE-588)144000873  |0 (DE-627)656392894  |0 (DE-576)340264438  |4 aut 
700 1 |a Vetter, Sven Y.  |d 1977-  |e VerfasserIn  |0 (DE-588)13390444X  |0 (DE-627)557959306  |0 (DE-576)300182740  |4 aut 
700 1 |a Grützner, Paul Alfred  |d 1962-  |e VerfasserIn  |0 (DE-588)111926688  |0 (DE-627)728553473  |0 (DE-576)372572863  |4 aut 
700 1 |a Franke, Jochen  |d 1974-  |e VerfasserIn  |0 (DE-588)124225373  |0 (DE-627)70657799X  |0 (DE-576)294076654  |4 aut 
700 1 |a Keil, Holger  |d 1984-  |e VerfasserIn  |0 (DE-588)1019810939  |0 (DE-627)687018048  |0 (DE-576)35890529X  |4 aut 
773 0 8 |i Enthalten in  |t Scientific reports  |d [London] : Springer Nature, 2011  |g 10(2020) Artikel-Nummer 4530, 8 Seiten  |h Online-Ressource  |w (DE-627)663366712  |w (DE-600)2615211-3  |w (DE-576)346641179  |x 2045-2322  |7 nnas  |a Diagnostic accuracy of intraoperative CT-imaging in complex articular fractures a cadaveric study 
773 1 8 |g volume:10  |g year:2020  |a Diagnostic accuracy of intraoperative CT-imaging in complex articular fractures a cadaveric study 
856 4 0 |u https://doi.org/10.1038/s41598-020-61267-w  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.nature.com/articles/s41598-020-61267-w  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20200914 
993 |a Article 
994 |a 2020 
998 |g 1019810939  |a Keil, Holger  |m 1019810939:Keil, Holger  |d 50000  |e 50000PK1019810939  |k 0/50000/  |p 7  |y j 
998 |g 124225373  |a Franke, Jochen  |m 124225373:Franke, Jochen  |d 50000  |e 50000PF124225373  |k 0/50000/  |p 6 
998 |g 111926688  |a Grützner, Paul Alfred  |m 111926688:Grützner, Paul Alfred  |d 50000  |e 50000PG111926688  |k 0/50000/  |p 5 
998 |g 13390444X  |a Vetter, Sven Y.  |m 13390444X:Vetter, Sven Y.  |d 50000  |e 50000PV13390444X  |k 0/50000/  |p 4 
998 |g 144000873  |a Schnetzke, Marc  |m 144000873:Schnetzke, Marc  |d 50000  |e 50000PS144000873  |k 0/50000/  |p 3 
998 |g 1069142913  |a Beisemann, Nils  |m 1069142913:Beisemann, Nils  |p 2 
998 |g 1217607234  |a Luxenhofer, Miriam  |m 1217607234:Luxenhofer, Miriam  |d 50000  |e 50000PL1217607234  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1731777086  |e 3752852771 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"note":["Gesehen am 14.09.2020"],"recId":"1731777086","relHost":[{"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 12.07.24"],"physDesc":[{"extent":"Online-Ressource"}],"recId":"663366712","disp":"Diagnostic accuracy of intraoperative CT-imaging in complex articular fractures a cadaveric studyScientific reports","title":[{"title_sort":"Scientific reports","title":"Scientific reports"}],"id":{"issn":["2045-2322"],"eki":["663366712"],"zdb":["2615211-3"]},"part":{"volume":"10","text":"10(2020) Artikel-Nummer 4530, 8 Seiten","year":"2020"},"origin":[{"dateIssuedKey":"2011","publisherPlace":"[London] ; London","publisher":"Springer Nature ; Nature Publishing Group","dateIssuedDisp":"2011-"}],"pubHistory":["1, article number 1 (2011)-"],"language":["eng"]}],"title":[{"subtitle":"a cadaveric study","title_sort":"Diagnostic accuracy of intraoperative CT-imaging in complex articular fractures","title":"Diagnostic accuracy of intraoperative CT-imaging in complex articular fractures"}],"name":{"displayForm":["M. Luxenhofer, N. Beisemann, M. Schnetzke, S.Y. Vetter, P.A. Grützner, J. Franke & H. Keil"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"given":"Miriam","role":"aut","display":"Luxenhofer, Miriam","family":"Luxenhofer"},{"family":"Beisemann","role":"aut","display":"Beisemann, Nils","given":"Nils"},{"family":"Schnetzke","role":"aut","display":"Schnetzke, Marc","given":"Marc"},{"given":"Sven Y.","family":"Vetter","role":"aut","display":"Vetter, Sven Y."},{"given":"Paul Alfred","family":"Grützner","display":"Grützner, Paul Alfred","role":"aut"},{"family":"Franke","role":"aut","display":"Franke, Jochen","given":"Jochen"},{"family":"Keil","role":"aut","display":"Keil, Holger","given":"Holger"}],"id":{"eki":["1731777086"],"doi":["10.1038/s41598-020-61267-w"]},"origin":[{"dateIssuedDisp":"11 March 2020","dateIssuedKey":"2020"}]} 
SRT |a LUXENHOFERDIAGNOSTIC1120