Imaging characteristics of intravascular spherical contrast agents for grating-based x-ray dark-field imaging: effects of concentrations, spherical sizes and applied voltage
This study investigates the x-ray scattering characteristics of microsphere particles in x-ray-grating-based interferometric imaging at different concentrations, bubble sizes and tube voltages (kV). Attenuation (ATI), dark-field (DFI) and phase-contrast (PCI) images were acquired. Signal-to-noise (S...
Saved in:
| Main Authors: | , , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
10 June 2020
|
| In: |
Scientific reports
Year: 2020, Volume: 10 |
| ISSN: | 2045-2322 |
| DOI: | 10.1038/s41598-020-66395-x |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1038/s41598-020-66395-x Verlag, lizenzpflichtig, Volltext: https://www.nature.com/articles/s41598-020-66395-x |
| Author Notes: | Susan Notohamiprodjo, Karla Maria Treitl, Christian Hauke, Sven-Martin Sutter, Sigrid Auweter, Franz Pfeiffer, Maximilian Ferdinand Reiser and Katharina Hellbach |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1733258558 | ||
| 003 | DE-627 | ||
| 005 | 20220818201821.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200917s2020 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1038/s41598-020-66395-x |2 doi | |
| 035 | |a (DE-627)1733258558 | ||
| 035 | |a (DE-599)KXP1733258558 | ||
| 035 | |a (OCoLC)1341360475 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Notohamiprodjo, Susan |e VerfasserIn |0 (DE-588)1217827668 |0 (DE-627)1733258604 |4 aut | |
| 245 | 1 | 0 | |a Imaging characteristics of intravascular spherical contrast agents for grating-based x-ray dark-field imaging |b effects of concentrations, spherical sizes and applied voltage |c Susan Notohamiprodjo, Karla Maria Treitl, Christian Hauke, Sven-Martin Sutter, Sigrid Auweter, Franz Pfeiffer, Maximilian Ferdinand Reiser and Katharina Hellbach |
| 264 | 1 | |c 10 June 2020 | |
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 17.09.2020 | ||
| 520 | |a This study investigates the x-ray scattering characteristics of microsphere particles in x-ray-grating-based interferometric imaging at different concentrations, bubble sizes and tube voltages (kV). Attenuation (ATI), dark-field (DFI) and phase-contrast (PCI) images were acquired. Signal-to-noise (SNR) and contrast-to-noise ratios with water (CNRw) and air as reference (CNRa) were determined. In all modalities, a linear relationship between SNR and microbubbles concentration, respectively, microsphere size was found. A significant gain of SNR was found when varying kV. SNR was significantly higher in DFI and PCI than ATI. The highest gain of SNR was shown at 60 kV for all media in ATI and DFI, at 80 kV for PCI. SNR for all media was significantly higher compared to air and was slightly lower compared to water. A linear relationship was found between CNRa, CNRw, concentration and size. With increasing concentration and decreasing size, CNRa and CNRw increased in DFI, but decreased in PCI. Best CNRa and CNRw was found at specific combination of kV and concentration/size. Highest average CNRa and CNRw was found for microspheres in ATI and PCI, for microbubbles in DFI. Microspheres are a promising contrast-media for grating-based-interferometry, if kV, microsphere size and concentration are appropriately combined. | ||
| 700 | 1 | |a Treitl, Karla Maria |e VerfasserIn |4 aut | |
| 700 | 1 | |a Hauke, Christian |e VerfasserIn |4 aut | |
| 700 | 1 | |a Sutter, Sven-Martin |e VerfasserIn |4 aut | |
| 700 | 1 | |a Auweter, Sigrid |e VerfasserIn |4 aut | |
| 700 | 1 | |a Pfeiffer, Franz |e VerfasserIn |4 aut | |
| 700 | 1 | |a Reiser, Maximilian Ferdinand |e VerfasserIn |4 aut | |
| 700 | 1 | |a Abbasi Dezfouli, Katharina |d 1985- |e VerfasserIn |0 (DE-588)1191431576 |0 (DE-627)1670077381 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Scientific reports |d [London] : Springer Nature, 2011 |g 10(2020) Artikel-Nummer 9405, 11 Seiten |h Online-Ressource |w (DE-627)663366712 |w (DE-600)2615211-3 |w (DE-576)346641179 |x 2045-2322 |7 nnas |a Imaging characteristics of intravascular spherical contrast agents for grating-based x-ray dark-field imaging effects of concentrations, spherical sizes and applied voltage |
| 773 | 1 | 8 | |g volume:10 |g year:2020 |a Imaging characteristics of intravascular spherical contrast agents for grating-based x-ray dark-field imaging effects of concentrations, spherical sizes and applied voltage |
| 856 | 4 | 0 | |u https://doi.org/10.1038/s41598-020-66395-x |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.nature.com/articles/s41598-020-66395-x |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200917 | ||
| 993 | |a Article | ||
| 994 | |a 2020 | ||
| 998 | |g 1191431576 |a Abbasi Dezfouli, Katharina |m 1191431576:Abbasi Dezfouli, Katharina |d 910000 |d 911400 |d 50000 |e 910000PA1191431576 |e 911400PA1191431576 |e 50000PA1191431576 |k 0/910000/ |k 1/910000/911400/ |k 0/50000/ |p 8 |y j | ||
| 999 | |a KXP-PPN1733258558 |e 375783917X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"note":["Gesehen am 17.09.2020"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisher":"Springer Nature ; Nature Publishing Group","dateIssuedKey":"2011","dateIssuedDisp":"2011-","publisherPlace":"[London] ; London"}],"id":{"eki":["663366712"],"zdb":["2615211-3"],"issn":["2045-2322"]},"pubHistory":["1, article number 1 (2011)-"],"part":{"year":"2020","text":"10(2020) Artikel-Nummer 9405, 11 Seiten","volume":"10"},"disp":"Imaging characteristics of intravascular spherical contrast agents for grating-based x-ray dark-field imaging effects of concentrations, spherical sizes and applied voltageScientific reports","note":["Gesehen am 12.07.24"],"type":{"bibl":"periodical","media":"Online-Ressource"},"recId":"663366712","language":["eng"],"title":[{"title_sort":"Scientific reports","title":"Scientific reports"}]}],"recId":"1733258558","origin":[{"dateIssuedDisp":"10 June 2020","dateIssuedKey":"2020"}],"title":[{"title_sort":"Imaging characteristics of intravascular spherical contrast agents for grating-based x-ray dark-field imaging","subtitle":"effects of concentrations, spherical sizes and applied voltage","title":"Imaging characteristics of intravascular spherical contrast agents for grating-based x-ray dark-field imaging"}],"id":{"eki":["1733258558"],"doi":["10.1038/s41598-020-66395-x"]},"person":[{"role":"aut","roleDisplay":"VerfasserIn","display":"Notohamiprodjo, Susan","given":"Susan","family":"Notohamiprodjo"},{"role":"aut","display":"Treitl, Karla Maria","roleDisplay":"VerfasserIn","given":"Karla Maria","family":"Treitl"},{"display":"Hauke, Christian","roleDisplay":"VerfasserIn","role":"aut","family":"Hauke","given":"Christian"},{"family":"Sutter","given":"Sven-Martin","roleDisplay":"VerfasserIn","display":"Sutter, Sven-Martin","role":"aut"},{"family":"Auweter","given":"Sigrid","display":"Auweter, Sigrid","roleDisplay":"VerfasserIn","role":"aut"},{"given":"Franz","family":"Pfeiffer","role":"aut","display":"Pfeiffer, Franz","roleDisplay":"VerfasserIn"},{"display":"Reiser, Maximilian Ferdinand","roleDisplay":"VerfasserIn","role":"aut","family":"Reiser","given":"Maximilian Ferdinand"},{"roleDisplay":"VerfasserIn","display":"Abbasi Dezfouli, Katharina","role":"aut","family":"Abbasi Dezfouli","given":"Katharina"}],"name":{"displayForm":["Susan Notohamiprodjo, Karla Maria Treitl, Christian Hauke, Sven-Martin Sutter, Sigrid Auweter, Franz Pfeiffer, Maximilian Ferdinand Reiser and Katharina Hellbach"]}} | ||
| SRT | |a NOTOHAMIPRIMAGINGCHA1020 | ||