Sciatic nerve injury related to hip replacement surgery: imaging detection by MR neurography despite susceptibility artifacts

Sciatic nerve palsy related to hip replacement surgery (HRS) is among the most common causes of sciatic neuropathies. The sciatic nerve may be injured by various different periprocedural mechanisms. The precise localization and extension of the nerve lesion, the determination of nerve continuity, le...

Full description

Saved in:
Bibliographic Details
Main Authors: Wolf, Marcel (Author) , Bäumer, Philipp (Author) , Pedro, Maria Teresa (Author) , Dombert, Thomas (Author) , Staub, Frank (Author) , Heiland, Sabine (Author) , Bendszus, Martin (Author) , Pham, Mirko (Author)
Format: Article (Journal)
Language:English
Published: February 18, 2014
In: PLOS ONE
Year: 2014, Volume: 9
ISSN:1932-6203
DOI:10.1371/journal.pone.0089154
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1371/journal.pone.0089154
Verlag, lizenzpflichtig, Volltext: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0089154
Get full text
Author Notes:Marcel Wolf, Philipp Bäumer, Maria Pedro, Thomas Dombert, Frank Staub, Sabine Heiland, Martin Bendszus, Mirko Pham

MARC

LEADER 00000caa a2200000 c 4500
001 1733669248
003 DE-627
005 20220818205344.0
007 cr uuu---uuuuu
008 200924s2014 xx |||||o 00| ||eng c
024 7 |a 10.1371/journal.pone.0089154  |2 doi 
035 |a (DE-627)1733669248 
035 |a (DE-599)KXP1733669248 
035 |a (OCoLC)1341361633 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Wolf, Marcel  |e VerfasserIn  |0 (DE-588)140366040  |0 (DE-627)618253777  |0 (DE-576)316608556  |4 aut 
245 1 0 |a Sciatic nerve injury related to hip replacement surgery  |b imaging detection by MR neurography despite susceptibility artifacts  |c Marcel Wolf, Philipp Bäumer, Maria Pedro, Thomas Dombert, Frank Staub, Sabine Heiland, Martin Bendszus, Mirko Pham 
264 1 |c February 18, 2014 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 24.09.2020 
520 |a Sciatic nerve palsy related to hip replacement surgery (HRS) is among the most common causes of sciatic neuropathies. The sciatic nerve may be injured by various different periprocedural mechanisms. The precise localization and extension of the nerve lesion, the determination of nerve continuity, lesion severity, and fascicular lesion distribution are essential for assessing the potential of spontaneous recovery and thereby avoiding delayed or inappropriate therapy. Adequate therapy is in many cases limited to conservative management, but in certain cases early surgical exploration and release of the nerve is indicated. Nerve-conduction-studies and electromyography are essential in the diagnosis of nerve injuries. In postsurgical nerve injuries, additional diagnostic imaging is important as well, in particular to detect or rule out direct mechanical compromise. Especially in the presence of metallic implants, commonly applied diagnostic imaging tests generally fail to adequately visualize nervous tissue. MRI has been deemed problematic due to implant-related artifacts after HRS. In this study, we describe for the first time the spectrum of imaging findings of Magnetic Resonance neurography (MRN) employing pulse sequences relatively insensitive to susceptibility artifacts (susceptibility insensitive MRN, siMRN) in a series of 9 patients with HRS procedure related sciatic nerve palsy. We were able to determine the localization and fascicular distribution of the sciatic nerve lesion in all 9 patients, which clearly showed on imaging predominant involvement of the peroneal more than the tibial division of the sciatic nerve. In 2 patients siMRN revealed direct mechanical compromise of the nerve by surgical material, and in one of these cases indication for surgical release of the sciatic nerve was based on siMRN. Thus, in selected cases of HRS related neuropathies, especially when surgical exploration of the nerve is considered, siMRN, with its potential to largely overcome implant related artifacts, is a useful diagnostic addition to nerve-conduction-studies and electromyography. 
650 4 |a Denervation 
650 4 |a Gastrocnemius muscles 
650 4 |a Lesions 
650 4 |a Magnetic resonance imaging 
650 4 |a Medical implants 
650 4 |a Muscle electrophysiology 
650 4 |a Sciatic nerves 
650 4 |a Surgical and invasive medical procedures 
700 1 |a Bäumer, Philipp  |d 1981-  |e VerfasserIn  |0 (DE-588)138369836  |0 (DE-627)696555735  |0 (DE-576)307128032  |4 aut 
700 1 |a Pedro, Maria Teresa  |d 1979-  |e VerfasserIn  |0 (DE-588)140355537  |0 (DE-627)703649221  |0 (DE-576)315045442  |4 aut 
700 1 |a Dombert, Thomas  |e VerfasserIn  |4 aut 
700 1 |a Staub, Frank  |e VerfasserIn  |4 aut 
700 1 |a Heiland, Sabine  |e VerfasserIn  |0 (DE-588)106732626X  |0 (DE-627)818624450  |0 (DE-576)426561368  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
700 1 |a Pham, Mirko  |d 1978-  |e VerfasserIn  |0 (DE-588)132435241  |0 (DE-627)522697763  |0 (DE-576)252667034  |4 aut 
773 0 8 |i Enthalten in  |t PLOS ONE  |d San Francisco, California, US : PLOS, 2006  |g 9(2014) Artikel-Nummer e89154, 10 Seiten  |h Online-Ressource  |w (DE-627)523574592  |w (DE-600)2267670-3  |w (DE-576)281331979  |x 1932-6203  |7 nnas  |a Sciatic nerve injury related to hip replacement surgery imaging detection by MR neurography despite susceptibility artifacts 
773 1 8 |g volume:9  |g year:2014  |g extent:10  |a Sciatic nerve injury related to hip replacement surgery imaging detection by MR neurography despite susceptibility artifacts 
856 4 0 |u https://doi.org/10.1371/journal.pone.0089154  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0089154  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200924 
993 |a Article 
994 |a 2014 
998 |g 132435241  |a Pham, Mirko  |m 132435241:Pham, Mirko  |d 910000  |d 911100  |d 50000  |e 910000PP132435241  |e 911100PP132435241  |e 50000PP132435241  |k 0/910000/  |k 1/910000/911100/  |k 0/50000/  |p 8  |y j 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911100  |e 910000PB1032676426  |e 911100PB1032676426  |k 0/910000/  |k 1/910000/911100/  |p 7 
998 |g 106732626X  |a Heiland, Sabine  |m 106732626X:Heiland, Sabine  |d 910000  |d 911100  |e 910000PH106732626X  |e 911100PH106732626X  |k 0/910000/  |k 1/910000/911100/  |p 6 
998 |g 138369836  |a Bäumer, Philipp  |m 138369836:Bäumer, Philipp  |d 910000  |d 911100  |e 910000PB138369836  |e 911100PB138369836  |k 0/910000/  |k 1/910000/911100/  |p 2 
998 |g 140366040  |a Wolf, Marcel  |m 140366040:Wolf, Marcel  |d 910000  |d 911100  |e 910000PW140366040  |e 911100PW140366040  |k 0/910000/  |k 1/910000/911100/  |p 1  |x j 
999 |a KXP-PPN1733669248  |e 3760733182 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["1733669248"],"doi":["10.1371/journal.pone.0089154"]},"recId":"1733669248","origin":[{"dateIssuedDisp":"February 18, 2014","dateIssuedKey":"2014"}],"name":{"displayForm":["Marcel Wolf, Philipp Bäumer, Maria Pedro, Thomas Dombert, Frank Staub, Sabine Heiland, Martin Bendszus, Mirko Pham"]},"language":["eng"],"note":["Gesehen am 24.09.2020"],"person":[{"role":"aut","family":"Wolf","display":"Wolf, Marcel","given":"Marcel"},{"given":"Philipp","display":"Bäumer, Philipp","family":"Bäumer","role":"aut"},{"display":"Pedro, Maria Teresa","family":"Pedro","role":"aut","given":"Maria Teresa"},{"display":"Dombert, Thomas","family":"Dombert","role":"aut","given":"Thomas"},{"display":"Staub, Frank","family":"Staub","role":"aut","given":"Frank"},{"display":"Heiland, Sabine","role":"aut","family":"Heiland","given":"Sabine"},{"given":"Martin","display":"Bendszus, Martin","role":"aut","family":"Bendszus"},{"given":"Mirko","role":"aut","family":"Pham","display":"Pham, Mirko"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"part":{"extent":"10","year":"2014","text":"9(2014) Artikel-Nummer e89154, 10 Seiten","volume":"9"},"language":["eng"],"name":{"displayForm":["Public Library of Science"]},"recId":"523574592","type":{"media":"Online-Ressource","bibl":"periodical"},"title":[{"title":"PLOS ONE","title_sort":"PLOS ONE"}],"note":["Schreibweise des Titels bis 2012: PLoS ONE","Gesehen am 20.03.19"],"pubHistory":["1.2006 -"],"disp":"Sciatic nerve injury related to hip replacement surgery imaging detection by MR neurography despite susceptibility artifactsPLOS ONE","corporate":[{"role":"isb","display":"Public Library of Science"}],"origin":[{"publisher":"PLOS ; PLoS","dateIssuedKey":"2006","publisherPlace":"San Francisco, California, US ; Lawrence, Kan.","dateIssuedDisp":"2006-"}],"id":{"zdb":["2267670-3"],"eki":["523574592"],"issn":["1932-6203"]}}],"title":[{"title":"Sciatic nerve injury related to hip replacement surgery","subtitle":"imaging detection by MR neurography despite susceptibility artifacts","title_sort":"Sciatic nerve injury related to hip replacement surgery"}],"physDesc":[{"extent":"10 S."}]} 
SRT |a WOLFMARCELSCIATICNER1820