Influence of acquisition settings and radiation exposure on CT lung densitometry—An anthropomorphic ex vivo phantom study

Objectives To systematically evaluate the influence of acquisition settings in conjunction with raw-data based iterative image reconstruction (IR) on lung densitometry based on multi-row detector computed tomography (CT) in an anthropomorphic chest phantom. Materials and methods Ten porcine heart-lu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Leutz-Schmidt, Patricia (VerfasserIn) , Wielpütz, Mark Oliver (VerfasserIn) , Skornitzke, Stephan (VerfasserIn) , Weinheimer, Oliver (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Puderbach, Michael (VerfasserIn) , Pahn, Gregor (VerfasserIn) , Stiller, Wolfram (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: August 14, 2020
In: PLOS ONE
Year: 2020, Jahrgang: 15, Heft: 8
ISSN:1932-6203
DOI:10.1371/journal.pone.0237434
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1371/journal.pone.0237434
Verlag, lizenzpflichtig, Volltext: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0237434
Volltext
Verfasserangaben:Patricia Leutz-Schmidt, Mark O. Wielpütz, Stephan Skornitzke, Oliver Weinheimer, Hans-Ulrich Kauczor, Michael U. Puderbach, Gregor Pahn, Wolfram Stiller

MARC

LEADER 00000caa a2200000 c 4500
001 1733674365
003 DE-627
005 20220818205430.0
007 cr uuu---uuuuu
008 200924s2020 xx |||||o 00| ||eng c
024 7 |a 10.1371/journal.pone.0237434  |2 doi 
035 |a (DE-627)1733674365 
035 |a (DE-599)KXP1733674365 
035 |a (OCoLC)1341361654 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Leutz-Schmidt, Patricia  |d 1989-  |e VerfasserIn  |0 (DE-588)1064715869  |0 (DE-627)814425801  |0 (DE-576)424077590  |4 aut 
245 1 0 |a Influence of acquisition settings and radiation exposure on CT lung densitometry—An anthropomorphic ex vivo phantom study  |c Patricia Leutz-Schmidt, Mark O. Wielpütz, Stephan Skornitzke, Oliver Weinheimer, Hans-Ulrich Kauczor, Michael U. Puderbach, Gregor Pahn, Wolfram Stiller 
264 1 |c August 14, 2020 
300 |a 13 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 24.09.2020 
520 |a Objectives To systematically evaluate the influence of acquisition settings in conjunction with raw-data based iterative image reconstruction (IR) on lung densitometry based on multi-row detector computed tomography (CT) in an anthropomorphic chest phantom. Materials and methods Ten porcine heart-lung explants were mounted in an ex vivo chest phantom shell, six with highly and four with low attenuating chest wall. CT (Somatom Definition Flash, Siemens Healthineers) was performed at 120kVp and 80kVp, each combined with current-time products of 120, 60, 30, and 12mAs, and was reconstructed with filtered back projection (FBP) and IR (Safire, Siemens Healthineers). Mean lung density (LD), air density (AD) and noise were measured by semi-automated region-of interest (ROI) analysis, with 120kVp/120 mAs serving as the standard of reference. Results Using IR, noise in lung parenchyma was reduced by ~ 31% at high attenuating chest wall and by ~ 22% at low attenuating chest wall compared to FBP, respectively (p<0.05). IR induced changes in the order of ±1 HU to mean absolute LD and AD compared to corresponding FBP reconstructions which were statistically significant (p<0.05). Conclusions Densitometry is influenced by acquisition parameters and reconstruction algorithms to a degree that may be clinically negligible. However, in longitudinal studies and clinical research identical protocols and potentially other measures for calibration may be required. 
650 4 |a Computed axial tomography 
650 4 |a Data acquisition 
650 4 |a Densitometry 
650 4 |a Infrared radiation 
650 4 |a Noise reduction 
650 4 |a Pulmonary imaging 
650 4 |a Radiation exposure 
650 4 |a Thoracic diaphragm 
700 1 |a Wielpütz, Mark Oliver  |d 1982-  |e VerfasserIn  |0 (DE-588)139999752  |0 (DE-627)614754682  |0 (DE-576)314127046  |4 aut 
700 1 |a Skornitzke, Stephan  |d 1987-  |e VerfasserIn  |0 (DE-588)1110072589  |0 (DE-627)864783523  |0 (DE-576)475718267  |4 aut 
700 1 |a Weinheimer, Oliver  |d 1973-  |e VerfasserIn  |0 (DE-588)133803473  |0 (DE-627)556388585  |0 (DE-576)30011558X  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Puderbach, Michael  |d 1974-  |e VerfasserIn  |0 (DE-588)123953669  |0 (DE-627)085545880  |0 (DE-576)293957452  |4 aut 
700 1 |a Pahn, Gregor  |e VerfasserIn  |0 (DE-588)1120442567  |0 (DE-627)873380088  |0 (DE-576)480343551  |4 aut 
700 1 |a Stiller, Wolfram  |d 1976-  |e VerfasserIn  |0 (DE-588)105822672X  |0 (DE-627)796627495  |0 (DE-576)414249496  |4 aut 
773 0 8 |i Enthalten in  |t PLOS ONE  |d San Francisco, California, US : PLOS, 2006  |g 15(2020,8) Artikel-Nummer e0237434, 13 Seiten  |h Online-Ressource  |w (DE-627)523574592  |w (DE-600)2267670-3  |w (DE-576)281331979  |x 1932-6203  |7 nnas  |a Influence of acquisition settings and radiation exposure on CT lung densitometry—An anthropomorphic ex vivo phantom study 
773 1 8 |g volume:15  |g year:2020  |g number:8  |g extent:13  |a Influence of acquisition settings and radiation exposure on CT lung densitometry—An anthropomorphic ex vivo phantom study 
856 4 0 |u https://doi.org/10.1371/journal.pone.0237434  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0237434  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200924 
993 |a Article 
994 |a 2020 
998 |g 105822672X  |a Stiller, Wolfram  |m 105822672X:Stiller, Wolfram  |d 910000  |d 911400  |e 910000PS105822672X  |e 911400PS105822672X  |k 0/910000/  |k 1/910000/911400/  |p 8  |y j 
998 |g 1120442567  |a Pahn, Gregor  |m 1120442567:Pahn, Gregor  |d 910000  |d 911400  |e 910000PP1120442567  |e 911400PP1120442567  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 123953669  |a Puderbach, Michael  |m 123953669:Puderbach, Michael  |d 910000  |d 950000  |d 950900  |e 910000PP123953669  |e 950000PP123953669  |e 950900PP123953669  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |p 6 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 5 
998 |g 133803473  |a Weinheimer, Oliver  |m 133803473:Weinheimer, Oliver  |d 910000  |d 911400  |e 910000PW133803473  |e 911400PW133803473  |k 0/910000/  |k 1/910000/911400/  |p 4 
998 |g 1110072589  |a Skornitzke, Stephan  |m 1110072589:Skornitzke, Stephan  |d 910000  |d 911400  |e 910000PS1110072589  |e 911400PS1110072589  |k 0/910000/  |k 1/910000/911400/  |p 3 
998 |g 139999752  |a Wielpütz, Mark Oliver  |m 139999752:Wielpütz, Mark Oliver  |d 910000  |d 911400  |d 50000  |e 910000PW139999752  |e 911400PW139999752  |e 50000PW139999752  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 2 
998 |g 1064715869  |a Leutz-Schmidt, Patricia  |m 1064715869:Leutz-Schmidt, Patricia  |d 910000  |d 911400  |e 910000PL1064715869  |e 911400PL1064715869  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1733674365  |e 3760753167 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1733674365","physDesc":[{"extent":"13 S."}],"origin":[{"dateIssuedKey":"2020","dateIssuedDisp":"August 14, 2020"}],"relHost":[{"name":{"displayForm":["Public Library of Science"]},"pubHistory":["1.2006 -"],"corporate":[{"role":"isb","display":"Public Library of Science"}],"id":{"issn":["1932-6203"],"eki":["523574592"],"zdb":["2267670-3"]},"part":{"year":"2020","issue":"8","volume":"15","text":"15(2020,8) Artikel-Nummer e0237434, 13 Seiten","extent":"13"},"origin":[{"publisher":"PLOS ; PLoS","publisherPlace":"San Francisco, California, US ; Lawrence, Kan.","dateIssuedKey":"2006","dateIssuedDisp":"2006-"}],"title":[{"title_sort":"PLOS ONE","title":"PLOS ONE"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"note":["Schreibweise des Titels bis 2012: PLoS ONE","Gesehen am 20.03.19"],"recId":"523574592","physDesc":[{"extent":"Online-Ressource"}],"disp":"Influence of acquisition settings and radiation exposure on CT lung densitometry—An anthropomorphic ex vivo phantom studyPLOS ONE"}],"person":[{"display":"Leutz-Schmidt, Patricia","role":"aut","given":"Patricia","family":"Leutz-Schmidt"},{"given":"Mark Oliver","role":"aut","family":"Wielpütz","display":"Wielpütz, Mark Oliver"},{"display":"Skornitzke, Stephan","given":"Stephan","role":"aut","family":"Skornitzke"},{"family":"Weinheimer","given":"Oliver","role":"aut","display":"Weinheimer, Oliver"},{"family":"Kauczor","given":"Hans-Ulrich","role":"aut","display":"Kauczor, Hans-Ulrich"},{"family":"Puderbach","given":"Michael","role":"aut","display":"Puderbach, Michael"},{"display":"Pahn, Gregor","family":"Pahn","given":"Gregor","role":"aut"},{"display":"Stiller, Wolfram","given":"Wolfram","role":"aut","family":"Stiller"}],"title":[{"title":"Influence of acquisition settings and radiation exposure on CT lung densitometry—An anthropomorphic ex vivo phantom study","title_sort":"Influence of acquisition settings and radiation exposure on CT lung densitometry—An anthropomorphic ex vivo phantom study"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 24.09.2020"],"name":{"displayForm":["Patricia Leutz-Schmidt, Mark O. Wielpütz, Stephan Skornitzke, Oliver Weinheimer, Hans-Ulrich Kauczor, Michael U. Puderbach, Gregor Pahn, Wolfram Stiller"]},"id":{"eki":["1733674365"],"doi":["10.1371/journal.pone.0237434"]}} 
SRT |a LEUTZSCHMIINFLUENCEO1420