Single-isocenter volumetric modulated arc therapy vs. cyberknife M6 for the stereotactic radiosurgery of multiple brain metastases

Introduction: Stereotactic radiosurgery (SRS) is becoming more frequently used for patients with multiple brain metastases (BM). Single-isocenter volumetric modulated arc therapy (SI-VMAT) is an emerging alternative to dedicated systems such as CyberKnife (CK). We present a dosimetric comparison bet...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: El-Shafie, Rami (VerfasserIn) , Schmitt, Daniela (VerfasserIn) , Kronsteiner, Dorothea (VerfasserIn) , Uzun-Lang, Kristin (VerfasserIn) , König, Laila (VerfasserIn) , Höne, Simon (VerfasserIn) , Forster, Tobias (VerfasserIn) , Nettelbladt, Bastian von (VerfasserIn) , Adeberg, Sebastian (VerfasserIn) , Debus, Jürgen (VerfasserIn) , Rieken, Stefan (VerfasserIn) , Bernhardt, Denise (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 08 May 2020
In: Frontiers in oncology
Year: 2020, Jahrgang: 10
ISSN:2234-943X
DOI:10.3389/fonc.2020.00568
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.3389/fonc.2020.00568
Verlag, kostenfrei, Volltext: https://www.frontiersin.org/articles/10.3389/fonc.2020.00568/full
Volltext
Verfasserangaben:Rami A. El Shafie, Eric Tonndorf-Martini, Daniela Schmitt, Aylin Celik, Dorothea Weber, Kristin Lang, Laila König, Simon Höne, Tobias Forster, Bastian von Nettelbladt, Sebastian Adeberg, Jürgen Debus, Stefan Rieken, and Denise Bernhardt

MARC

LEADER 00000caa a2200000 c 4500
001 1733940855
003 DE-627
005 20210820062750.0
007 cr uuu---uuuuu
008 200929s2020 xx |||||o 00| ||eng c
024 7 |a 10.3389/fonc.2020.00568  |2 doi 
035 |a (DE-627)1733940855 
035 |a (DE-599)KXP1733940855 
035 |a (OCoLC)1264385324 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a El-Shafie, Rami  |d 1989-  |e VerfasserIn  |0 (DE-588)110057378X  |0 (DE-627)859521427  |0 (DE-576)469743859  |4 aut 
245 1 0 |a Single-isocenter volumetric modulated arc therapy vs. cyberknife M6 for the stereotactic radiosurgery of multiple brain metastases  |c Rami A. El Shafie, Eric Tonndorf-Martini, Daniela Schmitt, Aylin Celik, Dorothea Weber, Kristin Lang, Laila König, Simon Höne, Tobias Forster, Bastian von Nettelbladt, Sebastian Adeberg, Jürgen Debus, Stefan Rieken, and Denise Bernhardt 
246 3 3 |a Single-isocenter volumetric modulated arc therapy versus cyberknife M6 for the stereotactic radiosurgery of multiple brain metastases 
264 1 |c 08 May 2020 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 29.09.2020 
520 |a Introduction: Stereotactic radiosurgery (SRS) is becoming more frequently used for patients with multiple brain metastases (BM). Single-isocenter volumetric modulated arc therapy (SI-VMAT) is an emerging alternative to dedicated systems such as CyberKnife (CK). We present a dosimetric comparison between CyberKnife M6 and SI-VMAT, planned at RayStation V8B, for the simultaneous SRS of five or more BM. Patients and methods: 20 treatment plans of CK-based single-session SRS to ≥5 brain metastases were re-planned using SI-VMAT for delivery at an Elekta VersaHD linear accelerator. Prescription dose was 20 or 18 Gy, conformally enclosing at least 98% of the total Planning Target Volume (PTV), with PTV margin-width adapted to the respective SRS technique. Comparatively analyzed quality metrics included dose distribution to the healthy brain (HB), including different isodose volumes, conformity and gradient indices. Estimated treatment time was also compared. Results: Median HB isodose volumes for 3, 5, 8, 10 and 12 Gy were consistently smaller for CK-SRS, compared to SI-VMAT (p<0.001). Dose falloff outside the target volume, as expressed by the gradient indices GI_high and GI_low, was consistently steeper for CK-SRS, compared to SI-VMAT (p<0.001). CK-SRS achieved a median GI_high of 3.1 [IQR 2.9 - 1.3] vs. 5.0 [IQR 4.3 - 5.5] for SI-VMAT (p<0.001). For GI_low, the results were 3.0 [IQR 2.9 - 3.1] for CK-SRS vs. 5.6 [IQR4.3 - 5.5] for SI-VMAT (p<0.001). The median conformity index (CI) was 1.2 [IQR 1.1 - 1.2] for CK-SRS vs. 1.5 [IQR 1.4 - 1.7) for SI-VMAT (p<0.001). Estimated treatment time was shorter for SI-VMAT, yielding a median of 13.7 min [IQR13.5 - 14.0], compared to 130 min [IQR 114.5 - 154.5] for CK-SRS (p<0.001). Conclusion: SI-VMAT offers enhanced treatment efficiency in cases with multiple BM, as compared to CyberKnife, but requires compromise regarding conformity and integral dose to the healthy brain. Additionally, delivery at a conventional linac may require larger safetya larger PTV margin to account for delivery and setup errorss. Further evaluations are warranted to determine whether the detected dosimetric differences are clinically relevant. SI-VMAT could be a reasonable alternative to a dedicated radiosurgery system for selected patients with multiple BM. 
700 1 |a Schmitt, Daniela  |e VerfasserIn  |0 (DE-588)1061089223  |0 (DE-627)804315590  |0 (DE-576)417190239  |4 aut 
700 1 |a Kronsteiner, Dorothea  |d 1991-  |e VerfasserIn  |0 (DE-588)1155734920  |0 (DE-627)1017938512  |0 (DE-576)501817794  |4 aut 
700 1 |a Uzun-Lang, Kristin  |d 1986-  |e VerfasserIn  |0 (DE-588)106868237X  |0 (DE-627)820592064  |0 (DE-576)428008569  |4 aut 
700 1 |a König, Laila  |d 1986-  |e VerfasserIn  |0 (DE-588)1053640579  |0 (DE-627)790403315  |0 (DE-576)409584282  |4 aut 
700 1 |a Höne, Simon  |e VerfasserIn  |0 (DE-588)1140810049  |0 (DE-627)898708095  |0 (DE-576)494067411  |4 aut 
700 1 |a Forster, Tobias  |d 1986-  |e VerfasserIn  |0 (DE-588)1102961132  |0 (DE-627)860567028  |0 (DE-576)470399430  |4 aut 
700 1 |a Nettelbladt, Bastian von  |d 1991-  |e VerfasserIn  |0 (DE-588)1207297755  |0 (DE-627)1693506823  |4 aut 
700 1 |a Adeberg, Sebastian  |d 1984-  |e VerfasserIn  |0 (DE-588)1049743377  |0 (DE-627)782574467  |0 (DE-576)403727774  |4 aut 
700 1 |a Debus, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1022671421  |0 (DE-627)717025780  |0 (DE-576)365774944  |4 aut 
700 1 |a Rieken, Stefan  |d 1979-  |e VerfasserIn  |0 (DE-588)135553385  |0 (DE-627)567062570  |0 (DE-576)278641725  |4 aut 
700 1 |a Bernhardt, Denise  |d 1987-  |e VerfasserIn  |0 (DE-588)1074875338  |0 (DE-627)832630691  |0 (DE-576)443070970  |4 aut 
773 0 8 |i Enthalten in  |t Frontiers in oncology  |d Lausanne : Frontiers Media, 2011  |g 10(2020) Artikel-Nummer 568, 10 Seiten  |h Online-Ressource  |w (DE-627)684965518  |w (DE-600)2649216-7  |w (DE-576)35841184X  |x 2234-943X  |7 nnas  |a Single-isocenter volumetric modulated arc therapy vs. cyberknife M6 for the stereotactic radiosurgery of multiple brain metastases 
773 1 8 |g volume:10  |g year:2020  |g extent:10  |a Single-isocenter volumetric modulated arc therapy vs. cyberknife M6 for the stereotactic radiosurgery of multiple brain metastases 
856 4 0 |u https://doi.org/10.3389/fonc.2020.00568  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.frontiersin.org/articles/10.3389/fonc.2020.00568/full  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20200929 
993 |a Article 
994 |a 2020 
998 |g 1074875338  |a Bernhardt, Denise  |m 1074875338:Bernhardt, Denise  |p 14  |y j 
998 |g 135553385  |a Rieken, Stefan  |m 135553385:Rieken, Stefan  |d 50000  |e 50000PR135553385  |k 0/50000/  |p 13 
998 |g 1022671421  |a Debus, Jürgen  |m 1022671421:Debus, Jürgen  |d 910000  |d 911400  |e 910000PD1022671421  |e 911400PD1022671421  |k 0/910000/  |k 1/910000/911400/  |p 12 
998 |g 1049743377  |a Adeberg, Sebastian  |m 1049743377:Adeberg, Sebastian  |d 910000  |d 911400  |d 50000  |e 910000PA1049743377  |e 911400PA1049743377  |e 50000PA1049743377  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 11 
998 |g 1207297755  |a Nettelbladt, Bastian von  |m 1207297755:Nettelbladt, Bastian von  |d 910000  |d 911400  |e 910000PN1207297755  |e 911400PN1207297755  |k 0/910000/  |k 1/910000/911400/  |p 10 
998 |g 1102961132  |a Forster, Tobias  |m 1102961132:Forster, Tobias  |d 910000  |d 911400  |e 910000PF1102961132  |e 911400PF1102961132  |k 0/910000/  |k 1/910000/911400/  |p 9 
998 |g 1140810049  |a Höne, Simon  |m 1140810049:Höne, Simon  |d 910000  |d 911400  |e 910000PH1140810049  |e 911400PH1140810049  |k 0/910000/  |k 1/910000/911400/  |p 8 
998 |g 1053640579  |a König, Laila  |m 1053640579:König, Laila  |d 910000  |d 911400  |e 910000PK1053640579  |e 911400PK1053640579  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 106868237X  |a Uzun-Lang, Kristin  |m 106868237X:Uzun-Lang, Kristin  |d 910000  |d 911400  |e 910000PU106868237X  |e 911400PU106868237X  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 1155734920  |a Kronsteiner, Dorothea  |m 1155734920:Kronsteiner, Dorothea  |d 910000  |d 999701  |e 910000PK1155734920  |e 999701PK1155734920  |k 0/910000/  |k 1/910000/999701/  |p 5 
998 |g 1061089223  |a Schmitt, Daniela  |m 1061089223:Schmitt, Daniela  |d 910000  |d 911400  |e 910000PS1061089223  |e 911400PS1061089223  |k 0/910000/  |k 1/910000/911400/  |p 3 
998 |g 110057378X  |a El-Shafie, Rami  |m 110057378X:El-Shafie, Rami  |d 910000  |d 911400  |e 910000PE110057378X  |e 911400PE110057378X  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1733940855  |e 3763872361 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1733940855","physDesc":[{"extent":"10 S."}],"title":[{"title_sort":"Single-isocenter volumetric modulated arc therapy vs. cyberknife M6 for the stereotactic radiosurgery of multiple brain metastases","title":"Single-isocenter volumetric modulated arc therapy vs. cyberknife M6 for the stereotactic radiosurgery of multiple brain metastases"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"note":["Gesehen am 29.09.2020"],"origin":[{"dateIssuedDisp":"08 May 2020","dateIssuedKey":"2020"}],"relHost":[{"pubHistory":["2011 -"],"origin":[{"dateIssuedKey":"2011","dateIssuedDisp":"2011-","publisherPlace":"Lausanne","publisher":"Frontiers Media"}],"title":[{"title_sort":"Frontiers in oncology","title":"Frontiers in oncology"}],"part":{"text":"10(2020) Artikel-Nummer 568, 10 Seiten","volume":"10","extent":"10","year":"2020"},"id":{"eki":["684965518"],"issn":["2234-943X"],"zdb":["2649216-7"]},"note":["Gesehen am 07.11.13"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"recId":"684965518","physDesc":[{"extent":"Online-Ressource"}],"disp":"Single-isocenter volumetric modulated arc therapy vs. cyberknife M6 for the stereotactic radiosurgery of multiple brain metastasesFrontiers in oncology"}],"person":[{"family":"El-Shafie","role":"aut","given":"Rami","display":"El-Shafie, Rami"},{"family":"Schmitt","given":"Daniela","role":"aut","display":"Schmitt, Daniela"},{"display":"Kronsteiner, Dorothea","family":"Kronsteiner","given":"Dorothea","role":"aut"},{"family":"Uzun-Lang","role":"aut","given":"Kristin","display":"Uzun-Lang, Kristin"},{"family":"König","role":"aut","given":"Laila","display":"König, Laila"},{"role":"aut","given":"Simon","family":"Höne","display":"Höne, Simon"},{"display":"Forster, Tobias","family":"Forster","role":"aut","given":"Tobias"},{"given":"Bastian von","role":"aut","family":"Nettelbladt","display":"Nettelbladt, Bastian von"},{"display":"Adeberg, Sebastian","family":"Adeberg","given":"Sebastian","role":"aut"},{"display":"Debus, Jürgen","given":"Jürgen","role":"aut","family":"Debus"},{"given":"Stefan","role":"aut","family":"Rieken","display":"Rieken, Stefan"},{"display":"Bernhardt, Denise","family":"Bernhardt","role":"aut","given":"Denise"}],"id":{"doi":["10.3389/fonc.2020.00568"],"eki":["1733940855"]},"name":{"displayForm":["Rami A. El Shafie, Eric Tonndorf-Martini, Daniela Schmitt, Aylin Celik, Dorothea Weber, Kristin Lang, Laila König, Simon Höne, Tobias Forster, Bastian von Nettelbladt, Sebastian Adeberg, Jürgen Debus, Stefan Rieken, and Denise Bernhardt"]},"titleAlt":[{"title":"Single-isocenter volumetric modulated arc therapy versus cyberknife M6 for the stereotactic radiosurgery of multiple brain metastases"}]} 
SRT |a ELSHAFIERASINGLEISOC0820