Determination of intrafraction prostate motion during external beam radiation therapy with a transperineal 4-dimensional ultrasound real-time tracking system
Purpose/Objective - To determine intrafraction prostate motion during volumetric modulated arc therapy (VMAT) using transperineal ultrasound (US) real-time tracking. - Methods and Materials - 770 US monitoring sessions in 38 prostate cancer patients' VMAT treatment series were retrospectively e...
Gespeichert in:
| Hauptverfasser: | , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
1 May 2018
|
| In: |
International journal of radiation oncology, biology, physics
Year: 2018, Jahrgang: 101, Heft: 1, Pages: 136-143 |
| ISSN: | 1879-355X |
| DOI: | 10.1016/j.ijrobp.2018.01.040 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ijrobp.2018.01.040 Verlag, lizenzpflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S0360301618301032 |
| Verfasserangaben: | Dwi Seno Kuncoro Sihono, Michael Ehmann, Sigrun Heitmann, Sandra von Swietochowski, Mario Grimm, Judit Boda-Heggemann, Frank Lohr, Frederik Wenz, and Hansjörg Wertz |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1733955585 | ||
| 003 | DE-627 | ||
| 005 | 20240407193259.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200929s2018 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.ijrobp.2018.01.040 |2 doi | |
| 035 | |a (DE-627)1733955585 | ||
| 035 | |a (DE-599)KXP1733955585 | ||
| 035 | |a (OCoLC)1341367820 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Sihono, Dwi Seno Kuncoro |d 1979- |e VerfasserIn |0 (DE-588)1073337642 |0 (DE-627)829090754 |0 (DE-576)434936057 |4 aut | |
| 245 | 1 | 0 | |a Determination of intrafraction prostate motion during external beam radiation therapy with a transperineal 4-dimensional ultrasound real-time tracking system |c Dwi Seno Kuncoro Sihono, Michael Ehmann, Sigrun Heitmann, Sandra von Swietochowski, Mario Grimm, Judit Boda-Heggemann, Frank Lohr, Frederik Wenz, and Hansjörg Wertz |
| 264 | 1 | |c 1 May 2018 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 29.09.2020 | ||
| 520 | |a Purpose/Objective - To determine intrafraction prostate motion during volumetric modulated arc therapy (VMAT) using transperineal ultrasound (US) real-time tracking. - Methods and Materials - 770 US monitoring sessions in 38 prostate cancer patients' VMAT treatment series were retrospectively evaluated. Intrafraction motion assessment of the prostate was based on continuous position monitoring with a 4-dimensional US system along the 3 directions: left-right (LR), anterior-posterior (AP), and inferior-superior (SI). The overall mean values and standard deviations (SD) along with random and systematic errors were calculated. - Results - The mean duration of each monitoring session was 254 s. The mean (μ), the systematic error (Σ), and the random error (σ) of intrafraction prostate displacement were μ = (0.01, −0.08, 0.15) mm, Σ = (0.30, 0.34, 0.23) mm, and σ = (0.59, 0.73, 0.64) mm in the LR, AP and SI directions, respectively. The percentage of treatments for which prostate displacement was ≤2 mm was 97.01%, 92.24%, and 95.77% in the LR, AP, and SI directions, respectively. At 60 s, a vector length of prostate displacement >2 mm was present in 0.67% of the data. The percentage increased to 2.42%, 6.14%, and 9.35% at 120 s, 180 s, and 240 s, respectively. - Conclusions - The magnitudes of intrafraction prostate motion along the SI and AP directions were comparable. On average, the smallest motion was in the LR direction and the largest in AP direction. Most of the prostate displacements were within a few millimeters. However, with increasing treatment time (eg, during hypofractionation), larger 3-dimensional prostate displacements up to 18.30 mm could be observed. Shortening treatment time can reduce the impact of intrafraction motion and potentially allows smaller safety margins. | ||
| 700 | 1 | |a Ehmann, Michael |d 1978- |e VerfasserIn |0 (DE-588)140496491 |0 (DE-627)618903615 |0 (DE-576)318527715 |4 aut | |
| 700 | 1 | |a Swietochowski, Sandra von |e VerfasserIn |0 (DE-588)1181827132 |0 (DE-627)166240106X |4 aut | |
| 700 | 1 | |a Grimm, Mario |d 1984- |e VerfasserIn |0 (DE-588)1178864529 |0 (DE-627)1049710010 |0 (DE-576)517936135 |4 aut | |
| 700 | 1 | |a Boda-Heggemann, Judit |d 1977- |e VerfasserIn |0 (DE-588)1029853436 |0 (DE-627)734363087 |0 (DE-576)377699411 |4 aut | |
| 700 | 1 | |a Wenz, Frederik |d 1966- |e VerfasserIn |0 (DE-588)113310390 |0 (DE-627)663837766 |0 (DE-576)346656281 |4 aut | |
| 700 | 1 | |a Wertz, Hansjörg |d 1976- |e VerfasserIn |0 (DE-588)143861247 |0 (DE-627)70462401X |0 (DE-576)339135778 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t International journal of radiation oncology, biology, physics |d Amsterdam [u.a.] : Elsevier Science, 1975 |g 101(2018), 1, Seite 136-143 |h Online-Ressource |w (DE-627)306659662 |w (DE-600)1500486-7 |w (DE-576)081986319 |x 1879-355X |7 nnas |a Determination of intrafraction prostate motion during external beam radiation therapy with a transperineal 4-dimensional ultrasound real-time tracking system |
| 773 | 1 | 8 | |g volume:101 |g year:2018 |g number:1 |g pages:136-143 |g extent:8 |a Determination of intrafraction prostate motion during external beam radiation therapy with a transperineal 4-dimensional ultrasound real-time tracking system |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.ijrobp.2018.01.040 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S0360301618301032 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200929 | ||
| 993 | |a Article | ||
| 994 | |a 2018 | ||
| 998 | |g 143861247 |a Wertz, Hansjörg |m 143861247:Wertz, Hansjörg |d 60000 |d 63000 |e 60000PW143861247 |e 63000PW143861247 |k 0/60000/ |k 1/60000/63000/ |p 9 |y j | ||
| 998 | |g 113310390 |a Wenz, Frederik |m 113310390:Wenz, Frederik |d 60000 |d 63000 |e 60000PW113310390 |e 63000PW113310390 |k 0/60000/ |k 1/60000/63000/ |p 8 | ||
| 998 | |g 1029853436 |a Boda-Heggemann, Judit |m 1029853436:Boda-Heggemann, Judit |d 60000 |d 63000 |e 60000PB1029853436 |e 63000PB1029853436 |k 0/60000/ |k 1/60000/63000/ |p 6 | ||
| 998 | |g 1178864529 |a Grimm, Mario |m 1178864529:Grimm, Mario |d 60000 |d 63000 |e 60000PG1178864529 |e 63000PG1178864529 |k 0/60000/ |k 1/60000/63000/ |p 5 | ||
| 998 | |g 1181827132 |a Swietochowski, Sandra von |m 1181827132:Swietochowski, Sandra von |d 60000 |d 63000 |e 60000PS1181827132 |e 63000PS1181827132 |k 0/60000/ |k 1/60000/63000/ |p 4 | ||
| 998 | |g 140496491 |a Ehmann, Michael |m 140496491:Ehmann, Michael |d 60000 |d 63000 |e 60000PE140496491 |e 63000PE140496491 |k 0/60000/ |k 1/60000/63000/ |p 2 | ||
| 998 | |g 1073337642 |a Sihono, Dwi Seno Kuncoro |m 1073337642:Sihono, Dwi Seno Kuncoro |d 60000 |d 63000 |e 60000PS1073337642 |e 63000PS1073337642 |k 0/60000/ |k 1/60000/63000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1733955585 |e 3763904271 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"name":{"displayForm":["Dwi Seno Kuncoro Sihono, Michael Ehmann, Sigrun Heitmann, Sandra von Swietochowski, Mario Grimm, Judit Boda-Heggemann, Frank Lohr, Frederik Wenz, and Hansjörg Wertz"]},"language":["eng"],"title":[{"title_sort":"Determination of intrafraction prostate motion during external beam radiation therapy with a transperineal 4-dimensional ultrasound real-time tracking system","title":"Determination of intrafraction prostate motion during external beam radiation therapy with a transperineal 4-dimensional ultrasound real-time tracking system"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedDisp":"1975-","publisher":"Elsevier Science","dateIssuedKey":"1975"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["1.1975/76 -"],"part":{"extent":"8","volume":"101","pages":"136-143","year":"2018","issue":"1","text":"101(2018), 1, Seite 136-143"},"disp":"Determination of intrafraction prostate motion during external beam radiation therapy with a transperineal 4-dimensional ultrasound real-time tracking systemInternational journal of radiation oncology, biology, physics","language":["eng"],"title":[{"title":"International journal of radiation oncology, biology, physics","subtitle":"the official journal of the American Society for Therapeutic Radiology and Oncology","title_sort":"International journal of radiation oncology, biology, physics"}],"note":["Gesehen am 15.01.20","Ungezählte Beil.: Supplement"],"id":{"zdb":["1500486-7"],"eki":["306659662"],"issn":["1879-355X"]},"recId":"306659662"}],"recId":"1733955585","person":[{"given":"Dwi Seno Kuncoro","roleDisplay":"VerfasserIn","role":"aut","display":"Sihono, Dwi Seno Kuncoro","family":"Sihono"},{"roleDisplay":"VerfasserIn","role":"aut","display":"Ehmann, Michael","family":"Ehmann","given":"Michael"},{"display":"Swietochowski, Sandra von","family":"Swietochowski","roleDisplay":"VerfasserIn","role":"aut","given":"Sandra von"},{"display":"Grimm, Mario","family":"Grimm","roleDisplay":"VerfasserIn","role":"aut","given":"Mario"},{"roleDisplay":"VerfasserIn","role":"aut","family":"Boda-Heggemann","display":"Boda-Heggemann, Judit","given":"Judit"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Wenz, Frederik","family":"Wenz","given":"Frederik"},{"given":"Hansjörg","display":"Wertz, Hansjörg","family":"Wertz","roleDisplay":"VerfasserIn","role":"aut"}],"id":{"doi":["10.1016/j.ijrobp.2018.01.040"],"eki":["1733955585"]},"note":["Gesehen am 29.09.2020"],"origin":[{"dateIssuedDisp":"1 May 2018","dateIssuedKey":"2018"}],"physDesc":[{"extent":"8 S."}],"type":{"bibl":"article-journal","media":"Online-Ressource"}} | ||
| SRT | |a SIHONODWISDETERMINAT1201 | ||