Determination of intrafraction prostate motion during external beam radiation therapy with a transperineal 4-dimensional ultrasound real-time tracking system

Purpose/Objective - To determine intrafraction prostate motion during volumetric modulated arc therapy (VMAT) using transperineal ultrasound (US) real-time tracking. - Methods and Materials - 770 US monitoring sessions in 38 prostate cancer patients' VMAT treatment series were retrospectively e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Sihono, Dwi Seno Kuncoro (VerfasserIn) , Ehmann, Michael (VerfasserIn) , Swietochowski, Sandra von (VerfasserIn) , Grimm, Mario (VerfasserIn) , Boda-Heggemann, Judit (VerfasserIn) , Wenz, Frederik (VerfasserIn) , Wertz, Hansjörg (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 1 May 2018
In: International journal of radiation oncology, biology, physics
Year: 2018, Jahrgang: 101, Heft: 1, Pages: 136-143
ISSN:1879-355X
DOI:10.1016/j.ijrobp.2018.01.040
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ijrobp.2018.01.040
Verlag, lizenzpflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S0360301618301032
Volltext
Verfasserangaben:Dwi Seno Kuncoro Sihono, Michael Ehmann, Sigrun Heitmann, Sandra von Swietochowski, Mario Grimm, Judit Boda-Heggemann, Frank Lohr, Frederik Wenz, and Hansjörg Wertz

MARC

LEADER 00000caa a2200000 c 4500
001 1733955585
003 DE-627
005 20240407193259.0
007 cr uuu---uuuuu
008 200929s2018 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ijrobp.2018.01.040  |2 doi 
035 |a (DE-627)1733955585 
035 |a (DE-599)KXP1733955585 
035 |a (OCoLC)1341367820 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Sihono, Dwi Seno Kuncoro  |d 1979-  |e VerfasserIn  |0 (DE-588)1073337642  |0 (DE-627)829090754  |0 (DE-576)434936057  |4 aut 
245 1 0 |a Determination of intrafraction prostate motion during external beam radiation therapy with a transperineal 4-dimensional ultrasound real-time tracking system  |c Dwi Seno Kuncoro Sihono, Michael Ehmann, Sigrun Heitmann, Sandra von Swietochowski, Mario Grimm, Judit Boda-Heggemann, Frank Lohr, Frederik Wenz, and Hansjörg Wertz 
264 1 |c 1 May 2018 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 29.09.2020 
520 |a Purpose/Objective - To determine intrafraction prostate motion during volumetric modulated arc therapy (VMAT) using transperineal ultrasound (US) real-time tracking. - Methods and Materials - 770 US monitoring sessions in 38 prostate cancer patients' VMAT treatment series were retrospectively evaluated. Intrafraction motion assessment of the prostate was based on continuous position monitoring with a 4-dimensional US system along the 3 directions: left-right (LR), anterior-posterior (AP), and inferior-superior (SI). The overall mean values and standard deviations (SD) along with random and systematic errors were calculated. - Results - The mean duration of each monitoring session was 254 s. The mean (μ), the systematic error (Σ), and the random error (σ) of intrafraction prostate displacement were μ = (0.01, −0.08, 0.15) mm, Σ = (0.30, 0.34, 0.23) mm, and σ = (0.59, 0.73, 0.64) mm in the LR, AP and SI directions, respectively. The percentage of treatments for which prostate displacement was ≤2 mm was 97.01%, 92.24%, and 95.77% in the LR, AP, and SI directions, respectively. At 60 s, a vector length of prostate displacement >2 mm was present in 0.67% of the data. The percentage increased to 2.42%, 6.14%, and 9.35% at 120 s, 180 s, and 240 s, respectively. - Conclusions - The magnitudes of intrafraction prostate motion along the SI and AP directions were comparable. On average, the smallest motion was in the LR direction and the largest in AP direction. Most of the prostate displacements were within a few millimeters. However, with increasing treatment time (eg, during hypofractionation), larger 3-dimensional prostate displacements up to 18.30 mm could be observed. Shortening treatment time can reduce the impact of intrafraction motion and potentially allows smaller safety margins. 
700 1 |a Ehmann, Michael  |d 1978-  |e VerfasserIn  |0 (DE-588)140496491  |0 (DE-627)618903615  |0 (DE-576)318527715  |4 aut 
700 1 |a Swietochowski, Sandra von  |e VerfasserIn  |0 (DE-588)1181827132  |0 (DE-627)166240106X  |4 aut 
700 1 |a Grimm, Mario  |d 1984-  |e VerfasserIn  |0 (DE-588)1178864529  |0 (DE-627)1049710010  |0 (DE-576)517936135  |4 aut 
700 1 |a Boda-Heggemann, Judit  |d 1977-  |e VerfasserIn  |0 (DE-588)1029853436  |0 (DE-627)734363087  |0 (DE-576)377699411  |4 aut 
700 1 |a Wenz, Frederik  |d 1966-  |e VerfasserIn  |0 (DE-588)113310390  |0 (DE-627)663837766  |0 (DE-576)346656281  |4 aut 
700 1 |a Wertz, Hansjörg  |d 1976-  |e VerfasserIn  |0 (DE-588)143861247  |0 (DE-627)70462401X  |0 (DE-576)339135778  |4 aut 
773 0 8 |i Enthalten in  |t International journal of radiation oncology, biology, physics  |d Amsterdam [u.a.] : Elsevier Science, 1975  |g 101(2018), 1, Seite 136-143  |h Online-Ressource  |w (DE-627)306659662  |w (DE-600)1500486-7  |w (DE-576)081986319  |x 1879-355X  |7 nnas  |a Determination of intrafraction prostate motion during external beam radiation therapy with a transperineal 4-dimensional ultrasound real-time tracking system 
773 1 8 |g volume:101  |g year:2018  |g number:1  |g pages:136-143  |g extent:8  |a Determination of intrafraction prostate motion during external beam radiation therapy with a transperineal 4-dimensional ultrasound real-time tracking system 
856 4 0 |u https://doi.org/10.1016/j.ijrobp.2018.01.040  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0360301618301032  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20200929 
993 |a Article 
994 |a 2018 
998 |g 143861247  |a Wertz, Hansjörg  |m 143861247:Wertz, Hansjörg  |d 60000  |d 63000  |e 60000PW143861247  |e 63000PW143861247  |k 0/60000/  |k 1/60000/63000/  |p 9  |y j 
998 |g 113310390  |a Wenz, Frederik  |m 113310390:Wenz, Frederik  |d 60000  |d 63000  |e 60000PW113310390  |e 63000PW113310390  |k 0/60000/  |k 1/60000/63000/  |p 8 
998 |g 1029853436  |a Boda-Heggemann, Judit  |m 1029853436:Boda-Heggemann, Judit  |d 60000  |d 63000  |e 60000PB1029853436  |e 63000PB1029853436  |k 0/60000/  |k 1/60000/63000/  |p 6 
998 |g 1178864529  |a Grimm, Mario  |m 1178864529:Grimm, Mario  |d 60000  |d 63000  |e 60000PG1178864529  |e 63000PG1178864529  |k 0/60000/  |k 1/60000/63000/  |p 5 
998 |g 1181827132  |a Swietochowski, Sandra von  |m 1181827132:Swietochowski, Sandra von  |d 60000  |d 63000  |e 60000PS1181827132  |e 63000PS1181827132  |k 0/60000/  |k 1/60000/63000/  |p 4 
998 |g 140496491  |a Ehmann, Michael  |m 140496491:Ehmann, Michael  |d 60000  |d 63000  |e 60000PE140496491  |e 63000PE140496491  |k 0/60000/  |k 1/60000/63000/  |p 2 
998 |g 1073337642  |a Sihono, Dwi Seno Kuncoro  |m 1073337642:Sihono, Dwi Seno Kuncoro  |d 60000  |d 63000  |e 60000PS1073337642  |e 63000PS1073337642  |k 0/60000/  |k 1/60000/63000/  |p 1  |x j 
999 |a KXP-PPN1733955585  |e 3763904271 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Dwi Seno Kuncoro Sihono, Michael Ehmann, Sigrun Heitmann, Sandra von Swietochowski, Mario Grimm, Judit Boda-Heggemann, Frank Lohr, Frederik Wenz, and Hansjörg Wertz"]},"language":["eng"],"title":[{"title_sort":"Determination of intrafraction prostate motion during external beam radiation therapy with a transperineal 4-dimensional ultrasound real-time tracking system","title":"Determination of intrafraction prostate motion during external beam radiation therapy with a transperineal 4-dimensional ultrasound real-time tracking system"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedDisp":"1975-","publisher":"Elsevier Science","dateIssuedKey":"1975"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["1.1975/76 -"],"part":{"extent":"8","volume":"101","pages":"136-143","year":"2018","issue":"1","text":"101(2018), 1, Seite 136-143"},"disp":"Determination of intrafraction prostate motion during external beam radiation therapy with a transperineal 4-dimensional ultrasound real-time tracking systemInternational journal of radiation oncology, biology, physics","language":["eng"],"title":[{"title":"International journal of radiation oncology, biology, physics","subtitle":"the official journal of the American Society for Therapeutic Radiology and Oncology","title_sort":"International journal of radiation oncology, biology, physics"}],"note":["Gesehen am 15.01.20","Ungezählte Beil.: Supplement"],"id":{"zdb":["1500486-7"],"eki":["306659662"],"issn":["1879-355X"]},"recId":"306659662"}],"recId":"1733955585","person":[{"given":"Dwi Seno Kuncoro","roleDisplay":"VerfasserIn","role":"aut","display":"Sihono, Dwi Seno Kuncoro","family":"Sihono"},{"roleDisplay":"VerfasserIn","role":"aut","display":"Ehmann, Michael","family":"Ehmann","given":"Michael"},{"display":"Swietochowski, Sandra von","family":"Swietochowski","roleDisplay":"VerfasserIn","role":"aut","given":"Sandra von"},{"display":"Grimm, Mario","family":"Grimm","roleDisplay":"VerfasserIn","role":"aut","given":"Mario"},{"roleDisplay":"VerfasserIn","role":"aut","family":"Boda-Heggemann","display":"Boda-Heggemann, Judit","given":"Judit"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Wenz, Frederik","family":"Wenz","given":"Frederik"},{"given":"Hansjörg","display":"Wertz, Hansjörg","family":"Wertz","roleDisplay":"VerfasserIn","role":"aut"}],"id":{"doi":["10.1016/j.ijrobp.2018.01.040"],"eki":["1733955585"]},"note":["Gesehen am 29.09.2020"],"origin":[{"dateIssuedDisp":"1 May 2018","dateIssuedKey":"2018"}],"physDesc":[{"extent":"8 S."}],"type":{"bibl":"article-journal","media":"Online-Ressource"}} 
SRT |a SIHONODWISDETERMINAT1201