Direct determination of lead isotopes (206Pb, 207Pb, 208Pb) in Arctic ice samples at picogram per gram levels using inductively coupled plasma-sector field MS coupled with a high-efficiency sample introduction system

Adopting strict cleanroom procedures, ice samples from the Canadian High Arctic have been analyzed for Pb concentrations and Pb isotopes (206Pb, 207Pb, 208Pb) using ICP-SMS. The detection limit for Pb (0.06 pg g-1) was ∼2 orders of magnitude lower than the lowest concentration of Pb in the ice sampl...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Krachler, Michael (VerfasserIn) , Zheng, Jiancheng (VerfasserIn) , Fisher, David (VerfasserIn) , Shotyk, William (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 30 July 2004
In: Analytical chemistry
Year: 2004, Jahrgang: 76, Heft: 18, Pages: 5510-5517
ISSN:1520-6882
DOI:10.1021/ac0496190
Online-Zugang:Verlag, Volltext: https://doi.org/10.1021/ac0496190
Volltext
Verfasserangaben:Michael Krachler, James Zheng, David Fisher, William Shotyk

MARC

LEADER 00000caa a2200000 c 4500
001 1734030178
003 DE-627
005 20230426162429.0
007 cr uuu---uuuuu
008 200930s2004 xx |||||o 00| ||eng c
024 7 |a 10.1021/ac0496190  |2 doi 
035 |a (DE-627)1734030178 
035 |a (DE-599)KXP1734030178 
035 |a (OCoLC)1341368109 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 31  |2 sdnb 
100 1 |a Krachler, Michael  |e VerfasserIn  |0 (DE-588)1058424734  |0 (DE-627)796871841  |0 (DE-576)414607627  |4 aut 
245 1 0 |a Direct determination of lead isotopes (206Pb, 207Pb, 208Pb) in Arctic ice samples at picogram per gram levels using inductively coupled plasma-sector field MS coupled with a high-efficiency sample introduction system  |c Michael Krachler, James Zheng, David Fisher, William Shotyk 
264 1 |c 30 July 2004 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 30.09.2020 
500 |a Im Titel sind die Ziffern "206", "207", "208" hochgestellt 
520 |a Adopting strict cleanroom procedures, ice samples from the Canadian High Arctic have been analyzed for Pb concentrations and Pb isotopes (206Pb, 207Pb, 208Pb) using ICP-SMS. The detection limit for Pb (0.06 pg g-1) was ∼2 orders of magnitude lower than the lowest concentration of Pb in the ice samples (range, 4.3−1660 pg g-1; median, 45 pg g-1). Acidification of ice samples with high-purity HNO3 for stabilization purposes contributed only 0.004 pg of Pb g-1, which is an insignificant source of Pb. Using a new sample introduction system consisting of a heated (140 °C) minicyclonic spray chamber and a Peltier cooled condenser (2 °C) and by replacing the conventional sample cone with a high-performance cone, signal intensities for Pb were increased by ∼1 order of magnitude. Thus, it was possible not only to measure Pb isotope ratios directly using ICP-SMS but also to achieve reasonable precision (∼0.2%) at low picogram per gram concentrations of total Pb. This precision is comparable to that achievable by thermal ionization mass spectrometry at such low Pb concentrations, but the ICP-SMS requires much less sample volume (∼2 mL), needs no sample pretreatment, and therefore is considerably faster and less expensive than the conventional approach. Even though absolute Pb concentrations in two ice samples dating from 1974 and 1852 were very similar (9 and 6 pg g-1) their fundamentally different isotopic signature (206Pb/207Pb:  1.169 ± 0.002 vs 1.147 ± 0.003) clearly indicates different sources of Pb. The analytical procedures described here, therefore, offer great promise for fingerprinting the predominant sources of atmospheric Pb in polar snow and ice. 
700 1 |a Zheng, Jiancheng  |d 1954-  |e VerfasserIn  |0 (DE-588)136861806  |0 (DE-627)694720186  |0 (DE-576)301314659  |4 aut 
700 1 |a Fisher, David  |e VerfasserIn  |4 aut 
700 1 |a Shotyk, William  |e VerfasserIn  |0 (DE-588)1058408577  |0 (DE-627)796855692  |0 (DE-576)366275321  |4 aut 
773 0 8 |i Enthalten in  |t Analytical chemistry  |d Columbus, Ohio : American Chemical Society, 1947  |g 76(2004), 18, Seite 5510-5517  |h Online-Ressource  |w (DE-627)300896530  |w (DE-600)1483443-1  |w (DE-576)088704564  |x 1520-6882  |7 nnas  |a Direct determination of lead isotopes (206Pb, 207Pb, 208Pb) in Arctic ice samples at picogram per gram levels using inductively coupled plasma-sector field MS coupled with a high-efficiency sample introduction system 
773 1 8 |g volume:76  |g year:2004  |g number:18  |g pages:5510-5517  |g extent:8  |a Direct determination of lead isotopes (206Pb, 207Pb, 208Pb) in Arctic ice samples at picogram per gram levels using inductively coupled plasma-sector field MS coupled with a high-efficiency sample introduction system 
856 4 0 |u https://doi.org/10.1021/ac0496190  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20200930 
993 |a Article 
994 |a 2004 
998 |g 1058408577  |a Shotyk, William  |m 1058408577:Shotyk, William  |d 120000  |d 120800  |d 120000  |d 121000  |e 120000PS1058408577  |e 120800PS1058408577  |e 120000PS1058408577  |e 121000PS1058408577  |k 0/120000/  |k 1/120000/120800/  |k 0/120000/  |k 1/120000/121000/  |p 4  |y j 
998 |g 136861806  |a Zheng, Jiancheng  |m 136861806:Zheng, Jiancheng  |d 120000  |d 120800  |d 120000  |d 121000  |e 120000PZ136861806  |e 120800PZ136861806  |e 120000PZ136861806  |e 121000PZ136861806  |k 0/120000/  |k 1/120000/120800/  |k 0/120000/  |k 1/120000/121000/  |p 2 
998 |g 1058424734  |a Krachler, Michael  |m 1058424734:Krachler, Michael  |d 120000  |d 120800  |d 120000  |d 121000  |e 120000PK1058424734  |e 120800PK1058424734  |e 120000PK1058424734  |e 121000PK1058424734  |k 0/120000/  |k 1/120000/120800/  |k 0/120000/  |k 1/120000/121000/  |p 1  |x j 
999 |a KXP-PPN1734030178  |e 3764179007 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1734030178"],"doi":["10.1021/ac0496190"]},"recId":"1734030178","name":{"displayForm":["Michael Krachler, James Zheng, David Fisher, William Shotyk"]},"person":[{"family":"Krachler","given":"Michael","roleDisplay":"VerfasserIn","role":"aut","display":"Krachler, Michael"},{"display":"Zheng, Jiancheng","role":"aut","roleDisplay":"VerfasserIn","given":"Jiancheng","family":"Zheng"},{"display":"Fisher, David","role":"aut","roleDisplay":"VerfasserIn","family":"Fisher","given":"David"},{"role":"aut","display":"Shotyk, William","roleDisplay":"VerfasserIn","family":"Shotyk","given":"William"}],"physDesc":[{"extent":"8 S."}],"note":["Gesehen am 30.09.2020","Im Titel sind die Ziffern \"206\", \"207\", \"208\" hochgestellt"],"language":["eng"],"title":[{"title_sort":"Direct determination of lead isotopes (206Pb, 207Pb, 208Pb) in Arctic ice samples at picogram per gram levels using inductively coupled plasma-sector field MS coupled with a high-efficiency sample introduction system","title":"Direct determination of lead isotopes (206Pb, 207Pb, 208Pb) in Arctic ice samples at picogram per gram levels using inductively coupled plasma-sector field MS coupled with a high-efficiency sample introduction system"}],"origin":[{"dateIssuedKey":"2004","dateIssuedDisp":"30 July 2004"}],"relHost":[{"name":{"displayForm":["American Chemical Society"]},"note":["Gesehen am 27.08.2020","Ungezählte Beil.: News & features"],"pubHistory":["19.1947 -"],"physDesc":[{"extent":"Online-Ressource"}],"recId":"300896530","id":{"zdb":["1483443-1"],"issn":["1520-6882"],"eki":["300896530"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"part":{"text":"76(2004), 18, Seite 5510-5517","extent":"8","volume":"76","pages":"5510-5517","year":"2004","issue":"18"},"disp":"Direct determination of lead isotopes (206Pb, 207Pb, 208Pb) in Arctic ice samples at picogram per gram levels using inductively coupled plasma-sector field MS coupled with a high-efficiency sample introduction systemAnalytical chemistry","origin":[{"dateIssuedKey":"1947","publisherPlace":"Columbus, Ohio","dateIssuedDisp":"1947-","publisher":"American Chemical Society"}],"title":[{"subtitle":"the authoritative voice of the analytical community","title":"Analytical chemistry","title_sort":"Analytical chemistry"}]}],"type":{"bibl":"article-journal","media":"Online-Ressource"}} 
SRT |a KRACHLERMIDIRECTDETE3020