Use of rapid reading software to reduce capsule endoscopy reading times while maintaining accuracy

Backgrounds and Aims: A typical capsule endoscopy (CE) case generates tens of thousands of images, with abnormalities often confined to a just few frames. Omni Mode is a novel EndoCapsule software algorithm (Olympus, Tokyo, Japan) that proposes to intelligently remove duplicate images while maintain...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Beg, Sabina (VerfasserIn) , Wronska, Ewa (VerfasserIn) , Araujo, Isis (VerfasserIn) , Suárez, Begona González (VerfasserIn) , Ivanova, Ekaterina (VerfasserIn) , Fedorov, Evgeny (VerfasserIn) , Aabakken, Lars (VerfasserIn) , Seitz, Uwe (VerfasserIn) , Rey, Jean-François (VerfasserIn) , Saurin, Jean-Christophe (VerfasserIn) , Tari, Roberto (VerfasserIn) , Card, Tim (VerfasserIn) , Ragunath, Krish (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: January 22, 2020
In: Gastrointestinal endoscopy
Year: 2020, Jahrgang: 91, Heft: 6, Pages: 1322-1327
ISSN:1097-6779
DOI:10.1016/j.gie.2020.01.026
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://dx.doi.org/10.1016/j.gie.2020.01.026
Verlag, lizenzpflichtig, Volltext: https://www.giejournal.org/article/S0016-5107(20)30052-3/abstract
Volltext
Verfasserangaben:Sabina Beg, Ewa Wronska, Isis Araujo, Begona González Suárez, Ekaterina Ivanova, Evgeny Fedorov, Lars Aabakken, Uwe Seitz, Jean-Francois Rey, Jean-Christophe Saurin, Roberto Tari, Tim Card, Krish Ragunath

MARC

LEADER 00000caa a2200000 c 4500
001 1734633212
003 DE-627
005 20230404125533.0
007 cr uuu---uuuuu
008 201005s2020 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.gie.2020.01.026  |2 doi 
035 |a (DE-627)1734633212 
035 |a (DE-599)KXP1734633212 
035 |a (OCoLC)1341368417 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Beg, Sabina  |e VerfasserIn  |0 (DE-588)1218991852  |0 (DE-627)1734636122  |4 aut 
245 1 0 |a Use of rapid reading software to reduce capsule endoscopy reading times while maintaining accuracy  |c Sabina Beg, Ewa Wronska, Isis Araujo, Begona González Suárez, Ekaterina Ivanova, Evgeny Fedorov, Lars Aabakken, Uwe Seitz, Jean-Francois Rey, Jean-Christophe Saurin, Roberto Tari, Tim Card, Krish Ragunath 
264 1 |c January 22, 2020 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 05.10.2020 
520 |a Backgrounds and Aims: A typical capsule endoscopy (CE) case generates tens of thousands of images, with abnormalities often confined to a just few frames. Omni Mode is a novel EndoCapsule software algorithm (Olympus, Tokyo, Japan) that proposes to intelligently remove duplicate images while maintaining accuracy in lesion detection. Methods: This prospective multicenter study took place across 9 European centers. Consecutive, unselected CE cases were read conventionally in normal mode, with every captured frame reviewed. Cases were subsequently anonymized and randomly allocated to another center where they were read using Omni Mode. Detected lesions and reading times were recorded, with findings compared between both viewing modes. The clinical significance of lesions was described according to the P classification (P0, P1, and P2). Where a discrepancy in lesion detection in either mode was found, expert blinded review at a consensus meeting was undertaken. Results: The patient population undergoing CE had a mean age of 49.5 years (range, 18-91), with the investigation of anemia or GI bleeding accounting for 71.8% of cases. The average small-bowel transit time was 4 hours, 26 minutes. The mean reading time in normal mode was 42.5 minutes. The use of Omni Mode was significantly faster (<i>P</i> < .0001), with an average time saving of 24.6 minutes (95% confidence interval, 22.8-26.9). The 2127 lesions were identified and classified according to the P classification as P0 (1234), P1 (656), and P2 (237). Lesions were identified using both reading modes in 40% (n = 936), and 1186 lesions were identified by either normal or Omni Mode alone. Normal mode interpretation was associated with 647 lesions being missed, giving an accuracy of .70. Omni Mode interpretation led to 539 lesions being missed, with an accuracy of .75. There was no significant difference in clinical conclusions made between either reading mode. Conclusions: This study shows that CE reading times can be reduced by an average of 40%, without any reduction in clinical accuracy. 
700 1 |a Wronska, Ewa  |e VerfasserIn  |4 aut 
700 1 |a Araujo, Isis  |e VerfasserIn  |4 aut 
700 1 |a Suárez, Begona González  |e VerfasserIn  |4 aut 
700 1 |a Ivanova, Ekaterina  |e VerfasserIn  |4 aut 
700 1 |a Fedorov, Evgeny  |e VerfasserIn  |4 aut 
700 1 |a Aabakken, Lars  |e VerfasserIn  |4 aut 
700 1 |a Seitz, Uwe  |e VerfasserIn  |0 (DE-588)1166806790  |0 (DE-627)1030674094  |0 (DE-576)510909205  |4 aut 
700 1 |a Rey, Jean-François  |d 1948-  |e VerfasserIn  |0 (DE-588)1066346925  |0 (DE-627)817329773  |0 (DE-576)425777251  |4 aut 
700 1 |a Saurin, Jean-Christophe  |e VerfasserIn  |4 aut 
700 1 |a Tari, Roberto  |e VerfasserIn  |4 aut 
700 1 |a Card, Tim  |e VerfasserIn  |4 aut 
700 1 |a Ragunath, Krish  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Gastrointestinal endoscopy  |d New York, NY : Elsevier, 1971  |g 91(2020), 6, Seite 1322-1327  |h Online-Ressource  |w (DE-627)320452719  |w (DE-600)2006253-9  |w (DE-576)094480400  |x 1097-6779  |7 nnas  |a Use of rapid reading software to reduce capsule endoscopy reading times while maintaining accuracy 
773 1 8 |g volume:91  |g year:2020  |g number:6  |g pages:1322-1327  |g extent:6  |a Use of rapid reading software to reduce capsule endoscopy reading times while maintaining accuracy 
856 4 0 |u https://dx.doi.org/10.1016/j.gie.2020.01.026  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.giejournal.org/article/S0016-5107(20)30052-3/abstract  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20201005 
993 |a Article 
994 |a 2020 
998 |g 1166806790  |a Seitz, Uwe  |m 1166806790:Seitz, Uwe  |p 8 
999 |a KXP-PPN1734633212  |e 3767017695 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"6 S."}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"dateIssuedDisp":"1971-","dateIssuedKey":"1971","publisher":"Elsevier ; Mosby","publisherPlace":"New York, NY ; St. Louis, Mo."}],"id":{"issn":["1097-6779"],"zdb":["2006253-9"],"eki":["320452719"]},"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 30.01.25"],"disp":"Use of rapid reading software to reduce capsule endoscopy reading times while maintaining accuracyGastrointestinal endoscopy","recId":"320452719","language":["eng"],"pubHistory":["Nachgewiesen 18.1971 -"],"part":{"year":"2020","issue":"6","pages":"1322-1327","text":"91(2020), 6, Seite 1322-1327","volume":"91","extent":"6"},"title":[{"title_sort":"Gastrointestinal endoscopy","title":"Gastrointestinal endoscopy","subtitle":"official journal of the American Society for Gastrointestinal Endoscopy"}]}],"origin":[{"dateIssuedKey":"2020","dateIssuedDisp":"January 22, 2020"}],"id":{"doi":["10.1016/j.gie.2020.01.026"],"eki":["1734633212"]},"name":{"displayForm":["Sabina Beg, Ewa Wronska, Isis Araujo, Begona González Suárez, Ekaterina Ivanova, Evgeny Fedorov, Lars Aabakken, Uwe Seitz, Jean-Francois Rey, Jean-Christophe Saurin, Roberto Tari, Tim Card, Krish Ragunath"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 05.10.2020"],"recId":"1734633212","language":["eng"],"title":[{"title_sort":"Use of rapid reading software to reduce capsule endoscopy reading times while maintaining accuracy","title":"Use of rapid reading software to reduce capsule endoscopy reading times while maintaining accuracy"}],"person":[{"role":"aut","roleDisplay":"VerfasserIn","display":"Beg, Sabina","given":"Sabina","family":"Beg"},{"family":"Wronska","given":"Ewa","roleDisplay":"VerfasserIn","display":"Wronska, Ewa","role":"aut"},{"display":"Araujo, Isis","roleDisplay":"VerfasserIn","role":"aut","family":"Araujo","given":"Isis"},{"display":"Suárez, Begona González","roleDisplay":"VerfasserIn","role":"aut","family":"Suárez","given":"Begona González"},{"given":"Ekaterina","family":"Ivanova","role":"aut","roleDisplay":"VerfasserIn","display":"Ivanova, Ekaterina"},{"display":"Fedorov, Evgeny","roleDisplay":"VerfasserIn","role":"aut","family":"Fedorov","given":"Evgeny"},{"family":"Aabakken","given":"Lars","roleDisplay":"VerfasserIn","display":"Aabakken, Lars","role":"aut"},{"family":"Seitz","given":"Uwe","roleDisplay":"VerfasserIn","display":"Seitz, Uwe","role":"aut"},{"display":"Rey, Jean-François","roleDisplay":"VerfasserIn","role":"aut","family":"Rey","given":"Jean-François"},{"display":"Saurin, Jean-Christophe","roleDisplay":"VerfasserIn","role":"aut","family":"Saurin","given":"Jean-Christophe"},{"role":"aut","display":"Tari, Roberto","roleDisplay":"VerfasserIn","given":"Roberto","family":"Tari"},{"family":"Card","given":"Tim","roleDisplay":"VerfasserIn","display":"Card, Tim","role":"aut"},{"roleDisplay":"VerfasserIn","display":"Ragunath, Krish","role":"aut","family":"Ragunath","given":"Krish"}]} 
SRT |a BEGSABINAWUSEOFRAPID2220