Comparative outcome analysis of internal screw fixation and Kirschner wire fixation in the treatment of scaphoid nonunion

In cases with difficult scaphoid screw placement due to small, fragile bone fragments, or transplants and insufficient space, the internal Kirschner wire fixation is a fallback option; however, controversy remains regarding its stability, safety, and outcome. Between 2001 and 2011, 95 patients were...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Engel, Holger (VerfasserIn) , Xiong, Lingyun (VerfasserIn) , Heffinger, Christian (VerfasserIn) , Kneser, Ulrich (VerfasserIn) , Hirche, Christoph (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 6 May 2020
In: Journal of plastic, reconstructive & aesthetic surgery
Year: 2020, Jahrgang: 73, Heft: 9, Pages: 1675-1682
ISSN:1878-0539
DOI:10.1016/j.bjps.2020.03.016
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.bjps.2020.03.016
Verlag, lizenzpflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S1748681520301479
Volltext
Verfasserangaben:Holger Engel, Lingyun Xiong, Christian Heffinger, Ulrich Kneser, Christoph Hirche

MARC

LEADER 00000caa a2200000 c 4500
001 1735207292
003 DE-627
005 20220818221452.0
007 cr uuu---uuuuu
008 201008s2020 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.bjps.2020.03.016  |2 doi 
035 |a (DE-627)1735207292 
035 |a (DE-599)KXP1735207292 
035 |a (OCoLC)1341370832 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Engel, Holger  |d 1976-  |e VerfasserIn  |0 (DE-588)132925214  |0 (DE-627)528681265  |0 (DE-576)265625378  |4 aut 
245 1 0 |a Comparative outcome analysis of internal screw fixation and Kirschner wire fixation in the treatment of scaphoid nonunion  |c Holger Engel, Lingyun Xiong, Christian Heffinger, Ulrich Kneser, Christoph Hirche 
264 1 |c 6 May 2020 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 08.10.2020 
520 |a In cases with difficult scaphoid screw placement due to small, fragile bone fragments, or transplants and insufficient space, the internal Kirschner wire fixation is a fallback option; however, controversy remains regarding its stability, safety, and outcome. Between 2001 and 2011, 95 patients were treated in our center (n=80 with cannulated compression screws and n=15 with Kirschner wires), and retrospectively analyzed. The outcome measurements included the analysis of patient data, union rate and analysis of functional measures, and quality of life. Bony reconstructions were performed with Vascularized Bone Grafts (VBG) based on the 1,2-Intercompartmental Supraretinacular Artery (ICSRA) , Medial Femoral Condyle (MFC)-VBG, cancellous bone, and iliac crest grafts. Bony healing and functional outcome showed no significant differences between Kirschner wire fixation and cannulated compression screws, although significantly more 1,2-ICSRA-VBG were treated with Kirschner wires. Although predominantly used as an intraoperative fallback option, our data demonstrate that Kirschner wire internal fixation can be safe and reliable, with comparable bony union rates and excellent functional outcomes. 
650 4 |a Cannulated screw 
650 4 |a Comparative study 
650 4 |a Internal screw fixation 
650 4 |a K wire 
650 4 |a Kirschner wire 
650 4 |a Scaphoid non-union 
700 1 |a Xiong, Lingyun  |d 1986-  |e VerfasserIn  |0 (DE-588)1105079880  |0 (DE-627)862468825  |0 (DE-576)473059517  |4 aut 
700 1 |a Heffinger, Christian  |d 1982-  |e VerfasserIn  |0 (DE-588)1053952015  |0 (DE-627)790838699  |0 (DE-576)409907480  |4 aut 
700 1 |a Kneser, Ulrich  |d 1972-  |e VerfasserIn  |0 (DE-588)123065119  |0 (DE-627)706147219  |0 (DE-576)293539987  |4 aut 
700 1 |a Hirche, Christoph  |e VerfasserIn  |0 (DE-588)1074918878  |0 (DE-627)832738484  |0 (DE-576)414117387  |4 aut 
773 0 8 |i Enthalten in  |t Journal of plastic, reconstructive & aesthetic surgery  |d Amsterdam [u.a.] : Elsevier, 2006  |g 73(2020), 9, Seite 1675-1682  |h Online-Ressource  |w (DE-627)504862758  |w (DE-600)2214150-9  |w (DE-576)251918033  |x 1878-0539  |7 nnas  |a Comparative outcome analysis of internal screw fixation and Kirschner wire fixation in the treatment of scaphoid nonunion 
773 1 8 |g volume:73  |g year:2020  |g number:9  |g pages:1675-1682  |g extent:8  |a Comparative outcome analysis of internal screw fixation and Kirschner wire fixation in the treatment of scaphoid nonunion 
856 4 0 |u https://doi.org/10.1016/j.bjps.2020.03.016  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S1748681520301479  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20201008 
993 |a Article 
994 |a 2020 
998 |g 1074918878  |a Hirche, Christoph  |m 1074918878:Hirche, Christoph  |d 50000  |e 50000PH1074918878  |k 0/50000/  |p 5  |y j 
998 |g 123065119  |a Kneser, Ulrich  |m 123065119:Kneser, Ulrich  |d 910000  |d 910400  |d 50000  |e 910000PK123065119  |e 910400PK123065119  |e 50000PK123065119  |k 0/910000/  |k 1/910000/910400/  |k 0/50000/  |p 4 
998 |g 1105079880  |a Xiong, Lingyun  |m 1105079880:Xiong, Lingyun  |p 2 
998 |g 132925214  |a Engel, Holger  |m 132925214:Engel, Holger  |d 50000  |e 50000PE132925214  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1735207292  |e 3772758894 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"language":["eng"],"id":{"zdb":["2214150-9"],"issn":["1878-0539"],"eki":["504862758"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"504862758","titleAlt":[{"title":"JPRAS"},{"title":"Journal of plastic, reconstructive and aesthetic surgery"}],"note":["Gesehen am 19.02.20"],"title":[{"title":"Journal of plastic, reconstructive & aesthetic surgery","subtitle":"JPRAS","title_sort":"Journal of plastic, reconstructive & aesthetic surgery"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"2006","publisherPlace":"Amsterdam [u.a.]","dateIssuedDisp":"2006-","publisher":"Elsevier"}],"disp":"Comparative outcome analysis of internal screw fixation and Kirschner wire fixation in the treatment of scaphoid nonunionJournal of plastic, reconstructive & aesthetic surgery","pubHistory":["59.2006 -"],"part":{"year":"2020","issue":"9","extent":"8","text":"73(2020), 9, Seite 1675-1682","volume":"73","pages":"1675-1682"}}],"name":{"displayForm":["Holger Engel, Lingyun Xiong, Christian Heffinger, Ulrich Kneser, Christoph Hirche"]},"origin":[{"dateIssuedDisp":"6 May 2020","dateIssuedKey":"2020"}],"title":[{"title_sort":"Comparative outcome analysis of internal screw fixation and Kirschner wire fixation in the treatment of scaphoid nonunion","title":"Comparative outcome analysis of internal screw fixation and Kirschner wire fixation in the treatment of scaphoid nonunion"}],"person":[{"role":"aut","given":"Holger","roleDisplay":"VerfasserIn","family":"Engel","display":"Engel, Holger"},{"roleDisplay":"VerfasserIn","display":"Xiong, Lingyun","family":"Xiong","given":"Lingyun","role":"aut"},{"role":"aut","given":"Christian","display":"Heffinger, Christian","family":"Heffinger","roleDisplay":"VerfasserIn"},{"display":"Kneser, Ulrich","family":"Kneser","roleDisplay":"VerfasserIn","role":"aut","given":"Ulrich"},{"family":"Hirche","display":"Hirche, Christoph","roleDisplay":"VerfasserIn","given":"Christoph","role":"aut"}],"note":["Gesehen am 08.10.2020"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"physDesc":[{"extent":"8 S."}],"language":["eng"],"id":{"eki":["1735207292"],"doi":["10.1016/j.bjps.2020.03.016"]},"recId":"1735207292"} 
SRT |a ENGELHOLGECOMPARATIV6202