Radiomics in diffusion data: a test-retest, inter- and intra-reader DWI phantom study

AIM - The aim of this study was to evaluate the robustness of radiomics features of a MRI (magnetic resonance imaging) phantom in quantitative diffusion-weighted imaging (DWI) and depending on the image resolution. - MATERIALS AND METHODS - Scanning of an in-house developed DWI phantom was performed...

Full description

Saved in:
Bibliographic Details
Main Authors: Dreher, Constantin (Author) , Kuder, Tristan Anselm (Author) , König, Franziska (Author) , Młynarska-Bujny, Anna (Author) , Tenconi, Chiara (Author) , Paech, Daniel (Author) , Schlemmer, Heinz-Peter (Author) , Ladd, Mark E. (Author) , Bickelhaupt, Sebastian (Author)
Format: Article (Journal)
Language:English
Published: 25 July 2020
In: Clinical radiology
Year: 2020, Volume: 75, Issue: 10, Pages: 798.e13-798.e22
ISSN:1365-229X
DOI:10.1016/j.crad.2020.06.024
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.crad.2020.06.024
Verlag, lizenzpflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S0009926020302579
Get full text
Author Notes:C. Dreher, T.A. Kuder, F. König, A. Mlynarska-Bujny, C. Tenconi, D. Paech, H.-P. Schlemmer, M.E. Ladd, S. Bickelhaupt

MARC

LEADER 00000caa a2200000 c 4500
001 1735649058
003 DE-627
005 20240407193346.0
007 cr uuu---uuuuu
008 201015s2020 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.crad.2020.06.024  |2 doi 
035 |a (DE-627)1735649058 
035 |a (DE-599)KXP1735649058 
035 |a (OCoLC)1341371005 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Dreher, Constantin  |d 1991-  |e VerfasserIn  |0 (DE-588)1075340934  |0 (DE-627)833201387  |0 (DE-576)44340805X  |4 aut 
245 1 0 |a Radiomics in diffusion data  |b a test-retest, inter- and intra-reader DWI phantom study  |c C. Dreher, T.A. Kuder, F. König, A. Mlynarska-Bujny, C. Tenconi, D. Paech, H.-P. Schlemmer, M.E. Ladd, S. Bickelhaupt 
264 1 |c 25 July 2020 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 15.10.2020 
520 |a AIM - The aim of this study was to evaluate the robustness of radiomics features of a MRI (magnetic resonance imaging) phantom in quantitative diffusion-weighted imaging (DWI) and depending on the image resolution. - MATERIALS AND METHODS - Scanning of an in-house developed DWI phantom was performed at a 1.5 T MRI scanner (Magnetom AERA, Siemens, Erlangen, Germany) using an echo planar imaging (EPI) DWI sequence (b=0,500,1,000 s/mm2) with low (3×3 mm2) and high (2×2 mm2) image resolutions. Scans were repeated after phantom repositioning to evaluate retest reliability. Radiomics features were extracted after semi-automatic segmentation and standardised pre-processing. Intra-/interobserver reproducibility and test-retest robustness were assessed using intraclass correlation coefficients (ICC). Differences were tested with non-parametric Wilcoxon's signed-rank and Friedman's test (p < 0.05) with Dunn's post-hoc analysis. - RESULTS - Test-retest ICC was overall high with >0.90 for 39/46 radiomics features in all sequences/resolutions. Decreased test-retest ICCs were pronounced for conventional Min-value (overall ICC=0.817), and grey-level zone length matrix (GLZLM) features Short-Zone Emphasis (SZE) and Short-Zone Low Grey-level Emphasis (SZLGE) (for both overall ICC=0.927). Test-retest reproducibility was significantly different between b=500, 1,000 and apparent diffusion coefficient (ADC) (mean 0.975±0.050, 0.974±0.051 and 0.966±0.063), which remained significant after post-hoc analysis between b=1,000 and ADC (p = 0.022). ICCs were not significantly different between resolutions of 2×2 and 3×3 mm2 regarding b=500 (mean: 0.977±0.052 and 0.974±0.049, p = 0.612), b=1,000 (mean: 0.973±0.059 and 0.974±0.054, p = 0.516), and ADC (mean: 0.972±0.049 and 0.955±0.101, p = 0.851). Inter- and intra-observer reliability was consistently high for all sequences (overall mean 0.992±0.021 and 0.990±0.028). - CONCLUSION - Under ex-vivo conditions, DWI provided robust radiomics features with those from ADC being slightly less robust than from raw DWI (b=500, 1,000 s/mm2). No significant difference was detected for different resolutions. Although, ex-vivo reliability of DWI radiomics features was high, no implications can be made regarding in-vivo analyses. 
700 1 |a Kuder, Tristan Anselm  |e VerfasserIn  |0 (DE-588)14203911X  |0 (DE-627)704126338  |0 (DE-576)326749675  |4 aut 
700 1 |a König, Franziska  |d 1987-  |e VerfasserIn  |0 (DE-588)1282585916  |0 (DE-627)1838249567  |4 aut 
700 1 |a Młynarska-Bujny, Anna  |d 1990-  |e VerfasserIn  |0 (DE-588)1216974608  |0 (DE-627)1728639042  |4 aut 
700 1 |a Tenconi, Chiara  |e VerfasserIn  |4 aut 
700 1 |a Paech, Daniel  |d 1986-  |e VerfasserIn  |0 (DE-588)1080278214  |0 (DE-627)844124893  |0 (DE-576)453464742  |4 aut 
700 1 |a Schlemmer, Heinz-Peter  |d 1961-  |e VerfasserIn  |0 (DE-588)1025559967  |0 (DE-627)722927142  |0 (DE-576)17334805X  |4 aut 
700 1 |a Ladd, Mark E.  |e VerfasserIn  |0 (DE-588)108120964X  |0 (DE-627)845690507  |0 (DE-576)454039999  |4 aut 
700 1 |a Bickelhaupt, Sebastian  |d 1984-  |e VerfasserIn  |0 (DE-588)1074040759  |0 (DE-627)83020668X  |0 (DE-576)435548131  |4 aut 
773 0 8 |i Enthalten in  |t Clinical radiology  |d Amsterdam : Elsevier Science, 1960  |g 75(2020), 10, Seite 798.e13-798.e22  |h Online-Ressource  |w (DE-627)320421252  |w (DE-600)2002588-9  |w (DE-576)103746889  |x 1365-229X  |7 nnas  |a Radiomics in diffusion data a test-retest, inter- and intra-reader DWI phantom study 
773 1 8 |g volume:75  |g year:2020  |g number:10  |g pages:798.e13-798.e22  |g extent:10  |a Radiomics in diffusion data a test-retest, inter- and intra-reader DWI phantom study 
856 4 0 |u https://doi.org/10.1016/j.crad.2020.06.024  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0009926020302579  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20201015 
993 |a Article 
994 |a 2020 
998 |g 1074040759  |a Bickelhaupt, Sebastian  |m 1074040759:Bickelhaupt, Sebastian  |d 130000  |e 130000PB1074040759  |k 0/130000/  |p 9  |y j 
998 |g 108120964X  |a Ladd, Mark E.  |m 108120964X:Ladd, Mark E.  |d 130000  |e 130000PL108120964X  |k 0/130000/  |p 8 
998 |g 1025559967  |a Schlemmer, Heinz-Peter  |m 1025559967:Schlemmer, Heinz-Peter  |d 50000  |e 50000PS1025559967  |k 0/50000/  |p 7 
998 |g 1080278214  |a Paech, Daniel  |m 1080278214:Paech, Daniel  |d 50000  |e 50000PP1080278214  |k 0/50000/  |p 6 
998 |g 1216974608  |a Młynarska-Bujny, Anna  |m 1216974608:Młynarska-Bujny, Anna  |d 50000  |e 50000PM1216974608  |k 0/50000/  |p 4 
998 |g 1282585916  |a König, Franziska  |m 1282585916:König, Franziska  |d 50000  |e 50000PK1282585916  |k 0/50000/  |p 3 
998 |g 14203911X  |a Kuder, Tristan Anselm  |m 14203911X:Kuder, Tristan Anselm  |d 130000  |e 130000PK14203911X  |k 0/130000/  |p 2 
998 |g 1075340934  |a Dreher, Constantin  |m 1075340934:Dreher, Constantin  |d 60000  |d 63000  |e 60000PD1075340934  |e 63000PD1075340934  |k 0/60000/  |k 1/60000/63000/  |p 1  |x j 
999 |a KXP-PPN1735649058  |e 3780116839 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"disp":"Radiomics in diffusion data a test-retest, inter- and intra-reader DWI phantom studyClinical radiology","note":["Gesehen am 04.02.20"],"title":[{"title_sort":"Clinical radiology","title":"Clinical radiology"}],"physDesc":[{"extent":"Online-Ressource"}],"language":["eng"],"origin":[{"publisher":"Elsevier Science ; Harcourt","dateIssuedDisp":"1960-","dateIssuedKey":"1960","publisherPlace":"Amsterdam ; Burlington, Mass."}],"recId":"320421252","pubHistory":["11.1960 -"],"part":{"volume":"75","year":"2020","extent":"10","pages":"798.e13-798.e22","issue":"10","text":"75(2020), 10, Seite 798.e13-798.e22"},"type":{"media":"Online-Ressource","bibl":"periodical"},"id":{"issn":["1365-229X"],"zdb":["2002588-9"],"eki":["320421252"]}}],"title":[{"title_sort":"Radiomics in diffusion data","subtitle":"a test-retest, inter- and intra-reader DWI phantom study","title":"Radiomics in diffusion data"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["1735649058"],"doi":["10.1016/j.crad.2020.06.024"]},"physDesc":[{"extent":"10 S."}],"language":["eng"],"person":[{"role":"aut","display":"Dreher, Constantin","given":"Constantin","family":"Dreher"},{"given":"Tristan Anselm","family":"Kuder","role":"aut","display":"Kuder, Tristan Anselm"},{"display":"König, Franziska","role":"aut","family":"König","given":"Franziska"},{"role":"aut","display":"Młynarska-Bujny, Anna","given":"Anna","family":"Młynarska-Bujny"},{"role":"aut","display":"Tenconi, Chiara","given":"Chiara","family":"Tenconi"},{"role":"aut","display":"Paech, Daniel","given":"Daniel","family":"Paech"},{"given":"Heinz-Peter","family":"Schlemmer","role":"aut","display":"Schlemmer, Heinz-Peter"},{"display":"Ladd, Mark E.","role":"aut","family":"Ladd","given":"Mark E."},{"role":"aut","display":"Bickelhaupt, Sebastian","given":"Sebastian","family":"Bickelhaupt"}],"origin":[{"dateIssuedDisp":"25 July 2020","dateIssuedKey":"2020"}],"note":["Gesehen am 15.10.2020"],"name":{"displayForm":["C. Dreher, T.A. Kuder, F. König, A. Mlynarska-Bujny, C. Tenconi, D. Paech, H.-P. Schlemmer, M.E. Ladd, S. Bickelhaupt"]},"recId":"1735649058"} 
SRT |a DREHERCONSRADIOMICSI2520