Comparison of the maximum applicable stretch force after femtosecond laser-assisted and manual anterior capsulotomy

Purpose: To objectively measure the strength of the capsulotomy performed with a femtosecond laser-assisted technique or performed manually in a pig-eye laboratory study. - Setting - International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelbe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Auffarth, Gerd U. (VerfasserIn) , Reddy, Kasu Prasad (VerfasserIn) , Ritter, Roland (VerfasserIn) , Holzer, Mike P. (VerfasserIn) , Rabsilber, Tanja Marina (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2013
In: Journal of cataract and refractive surgery
Year: 2013, Jahrgang: 39, Heft: 1, Pages: 105-109
ISSN:1873-4502
DOI:10.1016/j.jcrs.2012.08.065
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jcrs.2012.08.065
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/jcrs/Abstract/2013/01000/Comparison_of_the_maximum_applicable_stretch_force.17.aspx
Volltext
Verfasserangaben:Gerd U. Auffarth, MD, PhD, FEBO, Kasu Prasad Reddy, MD, Roland Ritter, MSc, Mike P. Holzer, MD, FEBO, Tanja M. Rabsilber, MD

MARC

LEADER 00000caa a2200000 c 4500
001 1736254367
003 DE-627
005 20240407193405.0
007 cr uuu---uuuuu
008 201022s2013 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jcrs.2012.08.065  |2 doi 
035 |a (DE-627)1736254367 
035 |a (DE-599)KXP1736254367 
035 |a (OCoLC)1341372985 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Auffarth, Gerd U.  |d 1964-  |e VerfasserIn  |0 (DE-588)123385261  |0 (DE-627)577130420  |0 (DE-576)293687277  |4 aut 
245 1 0 |a Comparison of the maximum applicable stretch force after femtosecond laser-assisted and manual anterior capsulotomy  |c Gerd U. Auffarth, MD, PhD, FEBO, Kasu Prasad Reddy, MD, Roland Ritter, MSc, Mike P. Holzer, MD, FEBO, Tanja M. Rabsilber, MD 
264 1 |c 2013 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 22.10.2020 
500 |a First published: 12 December 2012 
520 |a Purpose: To objectively measure the strength of the capsulotomy performed with a femtosecond laser-assisted technique or performed manually in a pig-eye laboratory study. - Setting - International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. - Design - Experimental study. - Methods - Ten fresh pig eyes were randomly assigned to femtosecond laser-assisted capsulotomy or manual capsulotomy. The capsule was immersed in hyaluronic acid, and retractors were fixed in the capsule opening with a pull-force measuring device. The force necessary to break the capsulotomy was measured in millinewtons (mN); the maximum stretching ratio was also assessed. - Results - The observed mean rupture force (ie, maximum amount of force measured immediately before tissue rupture) was 113 mN ± 12 (SD) in the laser-assisted procedure and 73 ± 22 mN in the manual procedure (P<.05). The stretching ratios were 1.60 ± 0.10 (femtosecond) and 1.35 ± 0.04 (manual) (P<.05). - Conclusion - In this laboratory pig-eye study, femtosecond laser-assisted capsulotomy resulted in a significantly stronger anterior capsule opening than the standard manually performed capsulotomy. - Financial Disclosure - Drs. Auffarth, Reddy, and Holzer have received research and travel grants from Technolas Perfect Vision GmbH. Mr. Ritter is an employee of Technolas Perfect Vision GmbH, Munich, Germany. 
700 1 |a Reddy, Kasu Prasad  |e VerfasserIn  |4 aut 
700 1 |a Ritter, Roland  |e VerfasserIn  |4 aut 
700 1 |a Holzer, Mike P.  |d 1973-  |e VerfasserIn  |0 (DE-588)122217527  |0 (DE-627)705818640  |0 (DE-576)293157812  |4 aut 
700 1 |a Rabsilber, Tanja Marina  |d 1977-  |e VerfasserIn  |0 (DE-588)128743271  |0 (DE-627)378689541  |0 (DE-576)297309609  |4 aut 
773 0 8 |i Enthalten in  |t Journal of cataract and refractive surgery  |d Hagerstown, MD : Wolters Kluwer Health, 1986  |g 39(2013), 1, Seite 105-109  |h Online-Ressource  |w (DE-627)320594203  |w (DE-600)2019330-0  |w (DE-576)260773891  |x 1873-4502  |7 nnas  |a Comparison of the maximum applicable stretch force after femtosecond laser-assisted and manual anterior capsulotomy 
773 1 8 |g volume:39  |g year:2013  |g number:1  |g pages:105-109  |g extent:5  |a Comparison of the maximum applicable stretch force after femtosecond laser-assisted and manual anterior capsulotomy 
856 4 0 |u https://doi.org/10.1016/j.jcrs.2012.08.065  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.lww.com/jcrs/Abstract/2013/01000/Comparison_of_the_maximum_applicable_stretch_force.17.aspx  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20201022 
993 |a Article 
994 |a 2013 
998 |g 128743271  |a Rabsilber, Tanja Marina  |m 128743271:Rabsilber, Tanja Marina  |d 910000  |d 910900  |e 910000PR128743271  |e 910900PR128743271  |k 0/910000/  |k 1/910000/910900/  |p 5  |y j 
998 |g 122217527  |a Holzer, Mike P.  |m 122217527:Holzer, Mike P.  |d 910000  |d 910900  |d 50000  |e 910000PH122217527  |e 910900PH122217527  |e 50000PH122217527  |k 0/910000/  |k 1/910000/910900/  |k 0/50000/  |p 4 
998 |g 123385261  |a Auffarth, Gerd U.  |m 123385261:Auffarth, Gerd U.  |d 910000  |d 910900  |e 910000PA123385261  |e 910900PA123385261  |k 0/910000/  |k 1/910000/910900/  |p 1  |x j 
999 |a KXP-PPN1736254367  |e 3784652409 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"5 S."}],"recId":"1736254367","relHost":[{"type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"Journal of cataract & refractive surgery"}],"note":["Gesehen am 02.08.24"],"physDesc":[{"extent":"Online-Ressource"}],"recId":"320594203","name":{"displayForm":["American Society of Cataract and Refractive Surgery"]},"title":[{"title":"Journal of cataract and refractive surgery","title_sort":"Journal of cataract and refractive surgery"}],"disp":"Comparison of the maximum applicable stretch force after femtosecond laser-assisted and manual anterior capsulotomyJournal of cataract and refractive surgery","origin":[{"dateIssuedDisp":"2020-","publisher":"Wolters Kluwer Health ; American Society of Cataract and Refractive Surgery ; Elsevier","publisherPlace":"Hagerstown, MD ; Fairfax, Va ; Amsterdam [u.a.]","dateIssuedKey":"2020"}],"part":{"issue":"1","volume":"39","extent":"5","text":"39(2013), 1, Seite 105-109","year":"2013","pages":"105-109"},"id":{"issn":["1873-4502"],"eki":["320594203"],"zdb":["2019330-0"]},"language":["eng"],"pubHistory":["12.1986 -"]}],"note":["Gesehen am 22.10.2020","First published: 12 December 2012"],"language":["eng"],"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"2013"}],"id":{"doi":["10.1016/j.jcrs.2012.08.065"],"eki":["1736254367"]},"person":[{"role":"aut","display":"Auffarth, Gerd U.","family":"Auffarth","given":"Gerd U."},{"display":"Reddy, Kasu Prasad","role":"aut","family":"Reddy","given":"Kasu Prasad"},{"family":"Ritter","role":"aut","display":"Ritter, Roland","given":"Roland"},{"given":"Mike P.","family":"Holzer","display":"Holzer, Mike P.","role":"aut"},{"given":"Tanja Marina","family":"Rabsilber","role":"aut","display":"Rabsilber, Tanja Marina"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title_sort":"Comparison of the maximum applicable stretch force after femtosecond laser-assisted and manual anterior capsulotomy","title":"Comparison of the maximum applicable stretch force after femtosecond laser-assisted and manual anterior capsulotomy"}],"name":{"displayForm":["Gerd U. Auffarth, MD, PhD, FEBO, Kasu Prasad Reddy, MD, Roland Ritter, MSc, Mike P. Holzer, MD, FEBO, Tanja M. Rabsilber, MD"]}} 
SRT |a AUFFARTHGECOMPARISON2013