Technological quality requirements for stereotactic radiotherapy: expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy

This review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Tec...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Schmitt, Daniela (VerfasserIn) , Blanck, Oliver (VerfasserIn) , Gauer, Tobias (VerfasserIn) , Fix, Michael K. (VerfasserIn) , Brunner, Thomas B. (VerfasserIn) , Fleckenstein, Jens (VerfasserIn) , Loutfi-Krauss, Britta (VerfasserIn) , Manser, Peter (VerfasserIn) , Werner, René (VerfasserIn) , Wilhelm, Maria-Lisa (VerfasserIn) , Baus, Wolfgang W. (VerfasserIn) , Moustakis, Christos (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 24 March 2020
In: Strahlentherapie und Onkologie
Year: 2020, Jahrgang: 196, Heft: 5, Pages: 421-443
ISSN:1439-099X
DOI:10.1007/s00066-020-01583-2
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1007/s00066-020-01583-2
Resolving-System, kostenfrei: http://dx.doi.org/10.1007/s00066-020-01583-2
Volltext
Verfasserangaben:$hDaniela Schmitt, Oliver Blanck, Tobias Gauer, Michael K. Fix, Thomas B. Brunner, Jens Fleckenstein, Britta Loutfi-Krauss, Peter Manser, Rene Werner, Maria-Lisa Wilhelm, Wolfgang W. Baus, Christos Moustakis

MARC

LEADER 00000caa a2200000 c 4500
001 1737462427
003 DE-627
005 20240407193415.0
007 cr uuu---uuuuu
008 201030s2020 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00066-020-01583-2  |2 doi 
035 |a (DE-627)1737462427 
035 |a (DE-599)KXP1737462427 
035 |a (OCoLC)1295680582 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schmitt, Daniela  |e VerfasserIn  |0 (DE-588)1061089223  |0 (DE-627)804315590  |0 (DE-576)417190239  |4 aut 
245 1 0 |a Technological quality requirements for stereotactic radiotherapy  |b expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy  |c $hDaniela Schmitt, Oliver Blanck, Tobias Gauer, Michael K. Fix, Thomas B. Brunner, Jens Fleckenstein, Britta Loutfi-Krauss, Peter Manser, Rene Werner, Maria-Lisa Wilhelm, Wolfgang W. Baus, Christos Moustakis 
264 1 |c 24 March 2020 
300 |a 23 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
520 |a This review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The covered aspects of this review are 1) imaging for target volume definition, 2) patient positioning and target volume localization, 3) motion management, 4) collimation of the irradiation and beam directions, 5) dose calculation, 6) treatment unit accuracy, and 7) dedicated quality assurance measures. For each part, an expert review for current state-of-the-art techniques and their particular technological quality requirement to reach the necessary accuracy for stereotactic radiotherapy divided into intracranial stereotactic radiosurgery in one single fraction (SRS), intracranial fractionated stereotactic radiotherapy (FSRT), and extracranial stereotactic body radiotherapy (SBRT) is presented. All recommendations and suggestions for all mentioned aspects of stereotactic radiotherapy are formulated and related uncertainties and potential sources of error discussed. Additionally, further research and development needs in terms of insufficient data and unsolved problems for stereotactic radiotherapy are identified, which will serve as a basis for the future assignments of the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The review was group peer-reviewed, and consensus was obtained through multiple working group meetings. 
700 1 |a Blanck, Oliver  |e VerfasserIn  |0 (DE-588)115998106X  |0 (DE-627)1023098768  |0 (DE-576)505430649  |4 aut 
700 1 |a Gauer, Tobias  |d 1980-  |e VerfasserIn  |0 (DE-588)141002492  |0 (DE-627)623818868  |0 (DE-576)321739965  |4 aut 
700 1 |a Fix, Michael K.  |e VerfasserIn  |4 aut 
700 1 |a Brunner, Thomas B.  |d 1967-  |e VerfasserIn  |0 (DE-588)1115676997  |0 (DE-627)869885723  |0 (DE-576)477869548  |4 aut 
700 1 |a Fleckenstein, Jens  |d 1981-  |e VerfasserIn  |0 (DE-588)102911918X  |0 (DE-627)732477212  |0 (DE-576)376584599  |4 aut 
700 1 |a Loutfi-Krauss, Britta  |e VerfasserIn  |4 aut 
700 1 |a Manser, Peter  |e VerfasserIn  |4 aut 
700 1 |a Werner, René  |d 1979-  |e VerfasserIn  |0 (DE-588)133973204  |0 (DE-627)55923645X  |0 (DE-576)30022673X  |4 aut 
700 1 |a Wilhelm, Maria-Lisa  |e VerfasserIn  |4 aut 
700 1 |a Baus, Wolfgang W.  |e VerfasserIn  |4 aut 
700 1 |a Moustakis, Christos  |d 1970-  |e VerfasserIn  |0 (DE-588)122453476  |0 (DE-627)705914240  |0 (DE-576)293278245  |4 aut 
773 0 8 |i Enthalten in  |t Strahlentherapie und Onkologie  |d Berlin : Springer Medizin, 1997  |g 196(2020), 5, Seite 421-443  |h Online-Ressource  |w (DE-627)312407866  |w (DE-600)2003907-4  |w (DE-576)090884809  |x 1439-099X  |7 nnas  |a Technological quality requirements for stereotactic radiotherapy expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy 
773 1 8 |g volume:196  |g year:2020  |g number:5  |g pages:421-443  |g extent:23  |a Technological quality requirements for stereotactic radiotherapy expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy 
856 4 0 |u https://doi.org/10.1007/s00066-020-01583-2  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u http://dx.doi.org/10.1007/s00066-020-01583-2  |x Resolving-System  |z kostenfrei 
951 |a AR 
992 |a 20211201 
993 |a Article 
994 |a 2020 
998 |g 102911918X  |a Fleckenstein, Jens  |m 102911918X:Fleckenstein, Jens  |d 60000  |d 63000  |e 60000PF102911918X  |e 63000PF102911918X  |k 0/60000/  |k 1/60000/63000/  |p 6 
998 |g 1061089223  |a Schmitt, Daniela  |m 1061089223:Schmitt, Daniela  |d 910000  |d 911400  |e 910000PS1061089223  |e 911400PS1061089223  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1737462427  |e 4010638222 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"role":"aut","given":"Daniela","family":"Schmitt","display":"Schmitt, Daniela"},{"display":"Blanck, Oliver","family":"Blanck","given":"Oliver","role":"aut"},{"given":"Tobias","role":"aut","display":"Gauer, Tobias","family":"Gauer"},{"family":"Fix","display":"Fix, Michael K.","role":"aut","given":"Michael K."},{"display":"Brunner, Thomas B.","family":"Brunner","given":"Thomas B.","role":"aut"},{"given":"Jens","role":"aut","display":"Fleckenstein, Jens","family":"Fleckenstein"},{"given":"Britta","role":"aut","display":"Loutfi-Krauss, Britta","family":"Loutfi-Krauss"},{"display":"Manser, Peter","family":"Manser","given":"Peter","role":"aut"},{"display":"Werner, René","family":"Werner","given":"René","role":"aut"},{"family":"Wilhelm","display":"Wilhelm, Maria-Lisa","role":"aut","given":"Maria-Lisa"},{"role":"aut","given":"Wolfgang W.","family":"Baus","display":"Baus, Wolfgang W."},{"given":"Christos","role":"aut","display":"Moustakis, Christos","family":"Moustakis"}],"name":{"displayForm":["$hDaniela Schmitt, Oliver Blanck, Tobias Gauer, Michael K. Fix, Thomas B. Brunner, Jens Fleckenstein, Britta Loutfi-Krauss, Peter Manser, Rene Werner, Maria-Lisa Wilhelm, Wolfgang W. Baus, Christos Moustakis"]},"relHost":[{"pubHistory":["Nachgewiesen 173.1997 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"subtitle":"journal of radiation oncology, biology, physics","title":"Strahlentherapie und Onkologie","title_sort":"Strahlentherapie und Onkologie"}],"id":{"eki":["312407866"],"issn":["1439-099X"],"zdb":["2003907-4"]},"origin":[{"dateIssuedKey":"1997","publisher":"Springer Medizin ; Urban & Vogel","dateIssuedDisp":"1997-","publisherPlace":"Berlin ; Heidelberg ; [München]"}],"part":{"issue":"5","pages":"421-443","volume":"196","year":"2020","text":"196(2020), 5, Seite 421-443","extent":"23"},"recId":"312407866","note":["Gesehen am 13.05.09"],"language":["ger"],"disp":"Technological quality requirements for stereotactic radiotherapy expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic RadiotherapyStrahlentherapie und Onkologie"}],"physDesc":[{"extent":"23 S."}],"title":[{"title":"Technological quality requirements for stereotactic radiotherapy","title_sort":"Technological quality requirements for stereotactic radiotherapy","subtitle":"expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["1737462427"],"doi":["10.1007/s00066-020-01583-2"]},"origin":[{"dateIssuedKey":"2020","dateIssuedDisp":"24 March 2020"}],"language":["eng"],"recId":"1737462427"} 
SRT |a SCHMITTDANTECHNOLOGI2420